Gingival pigmentation by Ni-Cr-based metal ceramic crowns: A clinical report

2016 ◽  
Vol 115 (1) ◽  
pp. 1-4 ◽  
Author(s):  
Min Tian ◽  
Sai Ma ◽  
Lina Niu ◽  
Jihua Chen
2012 ◽  
Vol 38 (6) ◽  
pp. 757-761 ◽  
Author(s):  
Fonda G. Robinson ◽  
Larry L. Cunningham

This clinical report describes the oral rehabilitation of an adult male who suffered severe dentoalveolar trauma as a result of a motor vehicle accident. The specific objectives of this treatment were to restore esthetics and masticatory function. Treatment included removal of fractured roots, placement of multiple endosseous implants, and placement of anterior and posterior metal-ceramic crowns and fixed partial dentures. Three year clinical examination revealed no pathology associated with the rehabilitation. The patient's esthetic and functional expectations were successfully achieved.


2022 ◽  
Vol 11 (1) ◽  
pp. e35211120077
Author(s):  
Karen Katlein Dolenkei ◽  
Lucas do Nascimento Tavares ◽  
Denildo de Magalhães ◽  
Luís Henrique Araújo Raposo

The aim of this clinical report is to present the replacement of unsatisfactory metal-ceramic crowns of elements 12, 11, 21 and 22, by lithium disilicate glass-reinforced ceramic crowns in a patient with skeletal anterior open bite. A patient sought care at the Dental Hospital at the School of Dentistry of UFU, complaining of odor between the metal-ceramic crowns of the antero-superior teeth. After clinical and radiographic examination, invasion of the biological space was noticed, surgery was indicated in order to restore the biological space. After healing, the pre-existing cast metal posts were masked using an opaque composite resin and the teeth were reprepared for full all-ceramic crowns. Impressions were taken in two steps, using PVS associated to retraction cords. The ceramic copings were obtained in lithium disilicate ceramic, and the veneering was performed by stratification. After testing the ceramics crowns in relation to, fit, function and aesthetic results, cementation was completed using modified absolute isolation, followed by prophylaxis of preparations with pumice and saline, surface treatment of the ceramic restorations and luting using self-adhesive resin cement. Finally, an occlusal splint was produced to control the effects of bruxism and orofacial pain symptoms. The anterior open skeletal bite was a challenging factor for the rehabilitation of this patient; however, one must consider the entire process that the patient would undergo if choosing for orthognathic surgery, and the patient should be aware of the case limitations. In addition, the use of lithium disilicate glass-reinforced ceramics proved the versatility of this material for anterior aesthetic restorations.


2007 ◽  
Vol 33 (1) ◽  
pp. 23-27 ◽  
Author(s):  
Jack Piermatti

Abstract Computer-assisted design (CAD) and computer-assisted manufacture (CAM) are technologic advancements used in dentistry today. These technologies have been developed to fabricate a complete arch substructure from a solid piece of titanium for a fixed, screw-retained implant-supported prosthesis. This clinical report demonstrates a treatment approach which uses CAD-CAM technology to incorporate a milled, titanium framework with retrievable metal ceramic crowns.


2006 ◽  
Vol 22 (5) ◽  
pp. 397-404 ◽  
Author(s):  
Jianxiang Tao ◽  
Masanobu Yoda ◽  
Kohei Kimura ◽  
Osamu Okuno

Author(s):  
Stepanov V.A. ◽  
Shemonaev V.I. ◽  
Buyanov E.A. ◽  
Grachev D.V. ◽  
Parchomenko A.N. ◽  
...  

The article presents the results of evaluating the prototyping of metal-ceramic structures made by casting and selective laser sintering. To achieve this goal, 27 patients with fabricated metal-ceramic crowns and bridgeworks were examined. Two study groups were created. The first group included 14 patients for whom dental prosthesis frameworks were made by casting. The second group consisted of 13 people, for whom the frames of dentures were made by the method of selective laser sintering. The analysis of clinical effectiveness was carried out according to the following criteria: 1- precision of the felling of prosthesis frame to solid tissues of abutment teeth; 2- the condition of the marginal periodontium; 3- the integrity of the ceramic cladding. The results of the study showed that the precision to solid tooth tissues of metal-ceramic dental prostheses made by laser selective sintering is higher than of frames made by casting. In accordance to the second criteria the best results were also shown by the participants of the second group. No chipping of the ceramic veneer from the metal-ceramic denture frameworks made by laser selective sintering was found. Thus, dentures which frameworks are made by the method of selective laser sintering are characterized by a higher objective assessment of their precision to the solid tissues of the abutment teeth. Lesions of the marginal periodontium both inflammatory and dystrophic were less in the participants of the second group. The frequency of defects in the coating of metal-ceramic dentures was significantly lower in the case of fabrication frameworks by laser selective sintering.


2008 ◽  
Vol os15 (1) ◽  
pp. 32-32
Author(s):  
P Limkangwalmongkol ◽  
GJ Chiche ◽  
MB Blatz
Keyword(s):  

2018 ◽  
Vol 34 ◽  
pp. e65-e66 ◽  
Author(s):  
P. Kunz ◽  
A.B.F. Fernandes ◽  
L.F. Cunha ◽  
G.M. Correr ◽  
C.C. Gonzaga
Keyword(s):  

2021 ◽  
Vol 14 (4) ◽  
pp. 38
Author(s):  
A.V. Ivaschenko ◽  
A.E. Yablokov ◽  
A.M. Nesterov ◽  
M.V. Shcherbakov ◽  
I.O. Buentsov ◽  
...  
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document