Sequential false data injection cyberattacks in water distribution systems targeting storage tanks; a bi-level optimization model

2021 ◽  
pp. 102895
Author(s):  
Faegheh Moazeni ◽  
Javad Khazaei
1988 ◽  
Vol 20 (11-12) ◽  
pp. 153-159 ◽  
Author(s):  
William D. Rosenzweig ◽  
Wesley O. Pipes

In recent years various types of imperfect fungi have been isolated from water systems. Fungal spores and mycelia can be inactivated by low concentrations of chlorine in the laboratory but survive in some habitats in water distribution systems. This report describes a field study which provides evidence that some types of fungi are able to grow in water distribution systems. Replicate samples from private residences were used to demonstrate that fungal densities are sometimes much greater than the levels which could be explained by adventitious spores. The microbiological content of water samples from fire hydrants was often significantly different from that of water samples from nearby private residences. The treated water input to distribution systems was found to be significantly lower in fungus content than water from private residences. Elevated storage tanks open to the atmosphere appear to be significant sources of fungal input to some systems.


2021 ◽  
Vol 11 (9) ◽  
Author(s):  
Pham Duc Dai

AbstractWater loss reduction in water distribution systems (WDSs) is a challenging task for water utilities worldwide. One of the most reliable and cost-effective ways to reduce water loss is to properly regulate operational pressure of the system through optimizing pressure reducing valve (PRV) placements. This well-known engineering problem can be casted into a mixed-integer nonlinear program (MINLP) where binary variables are introduced to represent positions of PRVs. Many works in the literature applied heuristic algorithms to address the optimization problem. In this paper, at first, we proposed a new optimization model and reformulated it as the mathematical program with complementarity constraints (MPCCs). It is due to the fact that the stationary point of the MPCCs is likely to be trapped into bad local solutions, a soft heuristic method is then proposed to determine the MINLP local solution in each iteration before a stationary point of the MPCCs is reached. This method not only enhances the quality of MINLP solution, but also decreases computation time for solving the MPCCs. The newly formulated MPCCs is applied to determine optimal localization of PRVs for two WDS benchmarks and a real-world WDS in Vietnam. The results are compared with others in the literature demonstrating that using our new optimization model, better and more reliable MINLP solution can be found for large scale WDSs.


Water ◽  
2021 ◽  
Vol 13 (11) ◽  
pp. 1606
Author(s):  
Matan Maskit ◽  
Avi Ostfeld

This study aims to develop and solve a multi-objective water distribution systems optimization problem incorporating pumps’ optimal scheduling and leakage minimization. An iterative optimization model was presented for calibrating and computing leakages in water distribution systems to recognize the critical impact of leakage control on system operation. The multi-dimensional and nonlinear optimization model, incorporating pump control, consumer demands, storage, and other water distribution systems’ components, was constructed and was minimized using a multi-objective genetic algorithm coupled with hydraulic simulations. The model was demonstrated on two example applications with increasing complexity through base runs and sensitivity analyses. Results showed that leakage minimization competes against pumping, mainly when significant differences occur between demands during low and high energy tariffs. Pumping during the periods with high electricity tariffs (when the demands are high) generated pressure distribution that decreased the overall leakage related to pump scheduling that replicated the natural inclination to pump as much as possible at low tariffs (when the demands are low). The optimal fronts were found to be very sensitive to the leakage exponent value, and changing its value indeed contradicted the balance between minimizing the leakage and the energy cost significantly. Altogether, the idea presented in this paper was found capable of facilitating the decision-makers to conveniently select between the energy-efficient pump scheduling and pump scheduling reflecting minimum leakage based on the system operator’s preferences. The research also paves the way to rebuild the optimization model by incorporating water distribution reliability and water quality that, in some cases, may also contradict the choice between energy cost and leakage minimization.


Sign in / Sign up

Export Citation Format

Share Document