Improved description of low-cycle fatigue behaviour of 316L steel under axial, torsional and combined loading using plastic J-integral

Author(s):  
Ondrej Slávik ◽  
Tomáš Vojtek ◽  
Ladislav Poczklán ◽  
Hector A. Tinoco ◽  
Tomáš Kruml ◽  
...  
1974 ◽  
Vol 188 (1) ◽  
pp. 321-328 ◽  
Author(s):  
W. J. Evans ◽  
G. P. Tilly

The low-cycle fatigue characteristics of an 11 per cent chromium steel, two nickel alloys and two titanium alloys have been studied in the range 20° to 500°C. For repeated-tension stress tests on all the materials, there was a sharp break in the stress-endurance curve between 103 and 104 cycles. The high stress failures were attributed to cyclic creep contributing to the development of internal cavities. At lower stresses, failures occurred through the growth of fatigue cracks initiated at the material surface. The whole fatigue curve could be represented by an expression developed from linear damage assumptions. Data for different temperatures and types of stress concentration were correlated by expressing stress as a fraction of the static strength. Repeated-tensile strain cycling data were represented on a stress-endurance diagram and it was shown that they correlated with push-pull stress cycles at high stresses and repeated-tension at low stresses. In general, the compressive phase tended to accentuate cyclic creep so that ductile failures occurred at proportionally lower stresses. Changes in frequency from 1 to 100 cycle/min were shown to have no significant effect on low-cycle fatigue behaviour.


1982 ◽  
Vol 68 (3) ◽  
pp. 471-476 ◽  
Author(s):  
Toshinori NAKAMURA ◽  
Masatake TOMINAGA ◽  
Hirokazu MURASE ◽  
Yukio NISHIYAMA

2018 ◽  
Vol 157 ◽  
pp. 05013 ◽  
Author(s):  
Peter Kopas ◽  
Milan Sága ◽  
František Nový ◽  
Bohuš Leitner

The article presents the results of research on low cycle fatigue strength of laser welded joints vs. non-welded material of high-strength steel DOMEX 700 MC. The tests were performed under load controlled using the total strain amplitude ɛac. The operating principle of the special electro-mechanic fatigue testing equipment with a suitable clamping system was working on 35 Hz frequency. Fatigue life analysis was conducted based on the Manson-Coffin-Basquin equation, which made it possible to determine fatigue parameters. Studies have shown differences in the fatigue life of original specimens and laser welded joints analysed, where laser welded joints showed lower fatigue resistance. In this article a numerical analysis of stresses generated in bending fatigue specimens has been performed employing the commercially available FEM-program ADINA.


2021 ◽  
Author(s):  
◽  
William Davey

TIMETAL®407 (Ti-407) is a medium strength (~650MPa 0.2%YS) titanium alloy, recently developed by TIMET, in conjunction with Rolls-Royce plc for use in applications requiring high energy absorption at impact. Preliminary Charpy Impact (V notch) testing showed Ti-407 to absorb nearly twice the impact energy of Ti-6-4 and exhibit more than 2.5 times the lateral expansion. Further initial testing suggested the high cycle fatigue (HCF) run out stress of Ti-407 matches that of Ti-6-4 and other high strength alpha-beta titanium alloys. Ti-407 displayed more than double the tool life than that of Ti-6-4. The reduction in tool wear supports lower forces required for faster, more efficient machining. Compared to Ti-6-4, the relatively low elevated temperature flow stress, greater malleability and wide process window should allow Ti-407 to be processed with fewer reheats, while exhibiting reduced surface cracking and giving a consistently good surface finish. Optimised Ti-407 manufacturing processes should allow parts to be formed closer to net shape giving higher yields and requiring less machining to the components finished size. This project has evaluated HCF, as well as low cycle fatigue (LCF) and dwell fatigue crack initiation mechanisms in Ti-407, to clarify the effects of alloy chemistry, microstructural morphology and scale, and crystallographic texture. A derivative of Ti-407, Ti-412 (~750MPa 0.2%YS) was also tested towards the end of the project and helped to further elucidate understanding of the fatigue characteristics of the two alloys. Of interest was the strong HCF response displayed relative to the monotonic tensile strength. As well as the investigation into the crack initiation mechanisms, an assessment of crack propagation across a range of microstructural conditions was carried out on Ti-407 material.


Sign in / Sign up

Export Citation Format

Share Document