Patch loading capacity for sinusoidal corrugated web girders

2021 ◽  
Vol 169 ◽  
pp. 108445
Author(s):  
Mohammad Reza Nikoomanesh ◽  
Mohammad Ali Goudarzi
2011 ◽  
Vol 250-253 ◽  
pp. 1271-1274
Author(s):  
Saggaff Anis ◽  
M.Md. Tahir ◽  
Arizu Sulaiman ◽  
Poi Ngian Shek ◽  
Cher Siang Tan ◽  
...  

The objective of this paper is to present the behaviour of composite beam using Trapezoid Web Profiled (TWP) steel section by determining the moment resistance and the deflection of the beam with composite and non-composite connections. The TWP steel section is a built up section where the flange is of S355 steel section and the corrugated web of S275 steel section. Three full scales testing setting-up as sub-assemblage frame have been carried out. It was concluded that the use of composite connection and extended end-plate has reduced significantly the deflection and has significantly increased the loading capacity of composite beam.


2010 ◽  
Vol 16 (2) ◽  
pp. 166-171 ◽  
Author(s):  
Hartmut Pasternak ◽  
Gabriel Kubieniec

Especially for the main frames of single‐storey steel buildings the use of corrugated web beams, mainly with sinusoidal corrugation, has been increased very much during the last years. Due to the thin web of 1,5 mm to 3 mm corrugated web beams afford a significant weight reduction compared with hot rolled profiles or welded I‐sections. Buckling failure of the web is prevented by the corrugation. The buckling resistance of presently used sinusoidal corrugated webs is comparable with plane webs of 12 mm thickness or more. Due to improvements of the automatic fabrication process corrugated webs up to 6 mm thickness became possible. Therefore the field of application of this beam type has been extended considerable. Even short span bridges are possible now. The dimensioning of corrugated web beams is ruled by the EN 1993–1‐5 Annex D ‐ it covers only web thicknesses up to 3 mm. In the last years many tests and finite element simulations have been carried out. Regarding this background, these EN rules will be discussed and extended. Furthermore, additional proposals for patch loading and lateral‐torsional buckling of girders with sinussoidal webs will be given. Santrauka Pastaruoju metu ypač vienaukščiu pastatu plieniniams remams imtos plačiai naudoti sijos su pagal sinusoide banguota sienele. Del plonu 1,5–3,0 mm storio gofruotuju siju sieneliu ju mase gerokai sumažeja, palyginti su karštai valcuotomis arba virintinemis dvitejo skerspjūvio sijomis. Sijos sieneles klumpamosios irties išvengiama del sieneles bangavimo. Šiuo metu naudojamu pagal sinusoide subanguotu sieneliu klumpamoji galia yra lygintina su 12 mm arba didesnio storio plokščiu sieneliu galia. Patobulinus automatini gaminimo procesa gofruotaja sienele galima padaryti iki 6 mm storio. Todel labai išsiplečia šiu siju naudojimo sritys. Sijos gali būti naudojamos nedidelio tarpatramio tiltams. Banguotasieniu siju projek‐tavimo metodika aprašyta EN 1993–1‐5 D priede, tačiau ji galioja tik sijoms, kuriu sieneles storis neviršija 3 mm. Pastarai‐siais metais atlikta daug bandymu ir skaitiniu eksperimentu baigtiniu elementu metodu. Todel šios EN projektavimo nuostatos bus aptariamos ir išplestos. Be to, straipsnyje pateiktos papildomos rekomendacijos, kaip vertinti siju su pagal sinusoide banguota sienele uždetaja apkrova ir lenkiamaji sukamaji klupuma.


2020 ◽  
Vol 0 (7) ◽  
pp. 45-56
Author(s):  
Lyudmila Lavrinenko ◽  
Danylo Oliinyk

2019 ◽  
Vol 233 ◽  
pp. 230-235 ◽  
Author(s):  
Li-li Lu ◽  
Wen-ya Xiong ◽  
Jun-bin Ma ◽  
Tian-fang Gao ◽  
Si-yuan Peng ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document