steel buildings
Recently Published Documents


TOTAL DOCUMENTS

535
(FIVE YEARS 138)

H-INDEX

27
(FIVE YEARS 6)

2022 ◽  
Vol 189 ◽  
pp. 107060
Author(s):  
Si-Yuan Zhai ◽  
Yi-Fan Lyu ◽  
Ke Cao ◽  
Guo-Qiang Li ◽  
Wei-Yong Wang ◽  
...  

2022 ◽  
Vol 12 (1) ◽  
pp. 433
Author(s):  
Federico Valenzuela-Beltrán ◽  
Mario D. Llanes-Tizoc ◽  
Edén Bojórquez ◽  
Juan Bojórquez ◽  
Robespierre Chávez ◽  
...  

The response of steel moment frames is estimated by first considering that the mass matrix is the concentrated type (ML) and then consistent type (MC). The effect of considering more than one element per beam is also evaluated. Low-, mid- and high-rise frames, modeled as complex-2D-MDOF systems, are used in the numerical study. Results indicate that if ML is used, depending upon the response parameter under consideration, the structural model, the seismic intensity and the structural location, the response can be significantly overestimated, precisely calculated, or significantly underestimated. Axial loads at columns, on an average basis, are significantly overestimated (up to 60%), while lateral drifts and flexural moments at beams are precisely calculated. Inter-story shears and flexural moments at columns, on average, are underestimated by up to 15% and 35%, respectively; however, underestimations of up to 60% can be seen for some individual strong motions. Similarly, if just one element per beam is used in the structural modeling, inter-story shears and axial loads on columns are overestimated, on average, by up to 21% and 95%, respectively, while the lateral drifts are precisely calculated. Flexural moments at columns and beams can be considerably underestimated (on average up to 14% and 35%, respectively), but underestimations larger than 50% can be seen for some individual cases. Hence, there is no error in terms of lateral drifts if ML or one element per beam is used, but significant errors can be introduced in the design due to the overestimation and underestimation of the design forces. It is strongly suggested to use MC and at least two elements per beam in the structural modeling.


Author(s):  
Deepan Dev B ◽  
Dr V Selvan

The seismic response of special moment-resisting frames (SMRF), buckling restrained braced (BRB) frames and self-centering energy dissipating (SCED) braced frames is compared when used in building structures many stories in height. The study involves pushover analysis as well as 2D and 3D nonlinear time history analysis for two ground motion hazard levels. The SCED and BRB braced frames generally experienced similar peak interstory drifts. The SMRF system had larger interstory drifts than both braced frames, especially for the shortest structures. The SCED system exhibited a more uniform distribution of the drift demand along the building height and was less prone to the biasing of the response in one direction due to P-Delta effects. The SCED frames also had significantly smaller residual lateral deformations. The two braced frame systems experienced similar interstory drift demand when used in torsional irregular structures.


2021 ◽  
Author(s):  
Kasra Habibi ◽  
S. Saeid Hosseini Varzandeh ◽  
Mojtaba Mahsuli

Abstract Quantification of the optimal target reliability based on the minimum lifecycle cost is the goal standard for calibration of seismic design provisions, which is yet to be fully-materialized even in the leading codes. Deviation from the optimally-calibrated design standards is significantly more pronounced in countries whose regulations are adopted from the few leading codes with no recalibration. A major challenge in the quantification of optimal target reliability for such countries is the lack of risk models that are suited for the local construction industry and design practices. This paper addresses this challenge by presenting an optimal target reliability quantification framework that tailors the available risk models for the countries from which the codes are adopted to the local conditions of the countries adopting the codes. The proposed framework is showcased through the national building code of Iran, which is adopted from the codes of the United States, using a case study of three midrise residential steel building archetypes. The archetypes have various structural systems including intermediate moment-resisting frame (IMF) and special concentrically braced frame (SCBF). Each of these archetypes are designed to different levels of the base shear coefficient, each of which corresponds to a level of reliability. To compute the lifecycle cost, the initial construction cost of buildings is estimated. Next, robust nonlinear models of these structures are generated, using which the probability distribution of structural responses and the collapse fragility are assessed through incremental dynamic analyses. Thereafter, the buildings are subjected to a detailed seismic risk analysis. Subsequently, the lifecycle cost of the buildings is computed as the sum of the initial construction cost and the seismic losses. Finally, the optimal strength and the corresponding target reliability to be prescribed are quantified based on the notion of minimum lifecycle cost. The results reveal a 50-year optimal reliability index of 2.0 and 2.1 for IMF and SCBF buildings, respectively and an optimal collapse probability given the maximum considered earthquake of 16% for both systems. In the context on the case study of the national building code of Iran, the optimal design base shear for IMF buildings is 40% higher than the current prescribed value by the code, whereas that of SCBF buildings is currently at the optimal level.


2021 ◽  
pp. 875529302110435
Author(s):  
Wael M Hassan ◽  
Janise Rodgers ◽  
Christopher Motter ◽  
John Thornley

Southcentral Alaska, the most populous region in Alaska, was violently shaken by a Mw 7.1 earthquake on 30 November 2018 at 8:29 am Alaska Standard Time. This was the largest magnitude earthquake in the United States close to a population center in over 50 years. The earthquake was 46 km deep, and the epicenter was 12 km north of Anchorage and 19 km west of Eagle River. The event affected some 400,000 residents, causing widespread damage in highways, nonstructural components, non-engineered and older buildings, and structures on poorly compacted fills. A few isolated serious injuries and partial collapses took place. Minor structural damage to code-conforming buildings was observed. A significant percentage of the structural damage was due to geotechnical failures. Building stock diversity allows use of the region as a large test bed to observe how local building practices affected earthquake damage levels. The prevailing peak ground acceleration (PGA) was 0.2–0.32 g, causing shaking intensity at most sites of 50%–60% of the ASCE 7-16 design basis earthquake acceleration. Thus, the seismic vulnerability of building stock in the region was not truly tested. Reinforced concrete buildings had minor structural damage, except in a few cases of shear wall and transfer girder shear cracking. Fiber-reinforced polymer (FRP)-retrofitted buildings performed satisfactorily. Concrete-masonry-unit (CMU) masonry buildings experienced serious structural damage in many cases, including relatively newer buildings. The earthquake caused widespread structural damage in non-engineered buildings (primarily wood and CMU masonry) that exist widely in the region, especially in Eagle River. Of these, non-engineered single-family wood buildings had the heaviest structural damage. No structural damage could be observed in steel buildings. The aftershock sequence, which included 7 M5+ and 50 M4+ events, exacerbated structural damage in all types of buildings. The present study is based on the EERI field reconnaissance mission conducted by the authors following the earthquake. Based on the observed damage and structural performance, seismic risk mitigation recommendations are suggested.


2021 ◽  
Vol 6 (12) ◽  
pp. 172
Author(s):  
Paraskevi K. Askouni ◽  
George A. Papagiannopoulos

This paper investigates the seismic behavior of a class of mixed reinforced concrete­–­steel buildings. In particular, mixed buildings constructed by r/c (reinforced concrete) at their lower story(ies) and structural steel at their upper story(ies) are studied from the viewpoint of their wide application in engineering praxis. The need to investigate the seismic behavior for this type of mixed buildings arises from the fact that the existent literature is small and that modern seismic codes do not offer specific seismic design recommendations for them. To study the seismic behavior of mixed r/c-steel buildings, a 3-D numerical model is employed and five realistic r/c-steel mixed buildings are simulated. Two cases of the support condition, i.e., fixed or pinned, of the lowest steel story to the upper r/c one are examined. The r/c and steel parts of the mixed buildings are initially designed as separate structures by making use of the relevant seismic design guidelines of Eurocode 8, and then the seismic response of these buildings is computed through non-linear time-history analyses. The special category of near-fault seismic motions is selected in these time-history analyses to force the mixed r/c-steel buildings under study to exhibit a strong non-linear response. Seismic response indices in terms of inter-story drift ratio, residual inter-story drift ratio and peak floor absolute accelerations are computed. The maximum values of these indices are discussed by comparing the two aforementioned kinds of support conditions and checking the satisfaction of specific seismic performance limits. Conclusions regarding the expected seismic behavior of mixed r/c-steel buildings under near-fault seismic motions are drawn. Finally, the need to introduce specific design recommendations for mixed r/c-steel buildings in modern seismic codes is stressed.


2021 ◽  
pp. 103881
Author(s):  
Mehmet Baris Batukan ◽  
Rafaela Sanches ◽  
Ashkan Hashemi ◽  
Oya Mercan ◽  
Amirahmad Fathieh ◽  
...  