Analysis and experimental study on servo dynamic stiffness of electromagnetic linear actuator

Author(s):  
Jiayu Lu ◽  
Bo Li ◽  
Wenqing Ge ◽  
Cao Tan ◽  
Binbin Sun
2014 ◽  
Vol 532 ◽  
pp. 41-45 ◽  
Author(s):  
Myung Jin Chung

Analytic model of electromagnetic linear actuator in the function of electric and geometric parameters is proposed and the effects of the design parameters on the dynamic characteristics are analyzed. To improve the dynamic characteristics, optimal design is conducted by applying sequential quadratic programming method to the analytic model. This optimal design method aims to minimize the response time and maximize force efficiency. By this procedure, electromagnetic linear actuator having high-speed characteristics is developed.


Author(s):  
Byung-Jin Kim ◽  
Jung-Hwan Sa ◽  
Jin-Sung Park ◽  
Hyun-Woo Park ◽  
Seong-Keun Cho ◽  
...  

2020 ◽  
Vol 2020 ◽  
pp. 1-9
Author(s):  
Jianlei Liu ◽  
Meng Ma ◽  
Flavio Stochino

The bearing capacity evaluation of bridge substructures is difficult as the static loading test (SLT) cannot be employed for the bridges in services. As a type of dynamic nondestructive test technique, the dynamic transient response method (TRM) could be employed to estimate the vertical bearing capacity when the relationship between static stiffness and dynamic stiffness is known. The TRM is usually employed to evaluate single piles. For the pier-cap-pile system, its applicability should be investigated. In the present study, a novel full-scale experimental study, including both TRM test and SLT, was performed on an abandoned bridge pier with grouped pile foundation. The test included three steps: firstly, testing the intact pier-cap-pile system; then, cutting off the pier and testing the cap-pile system; finally, cutting off the cap and testing the single pile. The TRM test was repeatedly performed in the above three steps, whereas the SLT was only performed on the cap-pile system. Based on the experimental results, the ratio of dynamic and static stiffness of the cap-pile system was obtained. The results show that (1) in the low-frequency range (between 10 and 30 Hz in this study), the dynamic stiffness of the whole system is approximately four times of that of a single pile; (2) the ratio of dynamic and static stiffness of the cap-pile system tested in the study is approximately 1.74, which was similar to other tested values of a single pile; (3) to evaluate the capacity of similar cap-pile system and with similar soil layer conditions by TRM, the value of Kd/Ks tested in the study can be used as a reference.


2013 ◽  
Vol 423-426 ◽  
pp. 1603-1607
Author(s):  
Yao Guo Xie ◽  
Ping He ◽  
Xian Qiang Qu ◽  
Hong Bin Cui

Through the analysis and comparison of the results of static and dynamic performance testing of a series of laminated steel pieces isolators used in the vibration isolation of warships, in the number and thickness of laminated steel pieces of the same circumstances, laminated steel arc and preload of test samples had a certain impact on the values ​​of static stiffness, dynamic stiffness, damping ratio as well as dynamic and static stiffness ratio.