Multiple Gastric Ulcers: Their Occurrence in Benign and Malignant Lesions

1953 ◽  
Vol 25 (2) ◽  
pp. 202-217 ◽  
Author(s):  
James A. Dolphin ◽  
Lucian A. Smith ◽  
John M. Waugh
2008 ◽  
Vol 190 (6) ◽  
pp. 1505-1511 ◽  
Author(s):  
Chiao-Yun Chen ◽  
Deng-Chyang Wu ◽  
Yu-Ting Kuo ◽  
Chien-Hung Lee ◽  
Twei-Shiun Jaw ◽  
...  

Author(s):  
S.K. Aggarwal ◽  
J. San Antonio

Cisplatin (cis-dichlorodiammineplatinum(II)) a potent antitumor agent is now available for the treatment of testicular and ovarian cancers. It is however, not free from its serious side effects including nephrotoxicity, gastro intestinal toxicity, myelosuppression, and ototoxicity. Here we now report that the drug produces peculiar bloating of the stomach in rats and induces acute ulceration.Wistar-derived rats weighing 200-250 g were administered cisplatin(9 mg/kg) ip as a single dose in 0.15 M NaCl. After 3 days the animals were sacrificed by decapitation. The stomachs were removed, the contents analyzed for pepsin and acidity. The inner surface was examined with a dissecting microscope after a moderate stretching for ulcers. Affected areas were fixed and processed for routine electron microscopy and enzyme cytochemistry.The drug treated animals kept on food and water consistently showed bloating and lesions (Fig. 1) with a frequency of 6-70 ulcers in the rumen section of the stomachs.


2001 ◽  
Vol 120 (5) ◽  
pp. A148-A148 ◽  
Author(s):  
M AKIMOTO ◽  
H HASHIMOTO ◽  
A MAEDA ◽  
M SHIGEMOTO ◽  
K YAMASHITA
Keyword(s):  

1964 ◽  
Vol 47 (1) ◽  
pp. 97-103 ◽  
Author(s):  
Nathan S. Taylor ◽  
Boris Gueft ◽  
Richard J. Lebowich

1953 ◽  
Vol 24 (3) ◽  
pp. 328-338 ◽  
Author(s):  
Rudolf Schindler ◽  
Jean-Jacques Desneux
Keyword(s):  

1952 ◽  
Vol 20 (1) ◽  
pp. 20-26 ◽  
Author(s):  
Frederick Steigmann ◽  
Bernard Shulman
Keyword(s):  

2002 ◽  
Vol 41 (05) ◽  
pp. 208-213 ◽  
Author(s):  
L. M. Haslinghuis-Bajan ◽  
L. Hooft ◽  
A. van Lingen ◽  
M. van Tulder ◽  
W. Devillé ◽  
...  

SummaryAim: While FDG full ring PET (FRPET) has been gradually accepted in oncology, the role of the cheaper gamma camera based alternatives (GCPET) is less clear. Since technology is evolving rapidly, “tracker trials” would be most helpful to provide a first approximation of the relative merits of these alternatives. As difference in scanner sensitivity is the key variable, head-to-head comparison with FRPET is an attractive study design. This systematic review summarises such studies. Methods: Nine studies were identified until July 1, 2000. Two observers assessed the methodological quality (Cochrane criteria), and extracted data. Results: The studies comprised a variety of tumours and indications. The reported GC- and FRPET agreement for detection of malignant lesions ranged from 55 to 100%, but with methodological limitations (blinding, standardisation, limited patient spectrum). Mean lesion diameter was 2.9 cm (SD 1.8), with only about 20% <1.5 cm. The 3 studies with the highest quality reported concordances of 74-79%, for the studied lesion spectrum. Contrast at GCPET was lower than that of FRPET, contrast and detection agreement were positively related. Logistic regression analysis suggested that pre-test indicators might be used to predict FRPET-GCPET concordance. Conclusion: In spite of methodological limitations, “first generation” GCPET devices detected sufficient FRPET positive lesions to allow prospective evaluation in clinical situations where the impact of FRPET is not confined to detection of small lesions (<1.5 cm). The efficiency of head-to-head comparative studies would benefit from application in a clinically relevant patient spectrum, with proper blinding and standardisation of acquisition procedures.


1997 ◽  
Vol 36 (08) ◽  
pp. 282-288 ◽  
Author(s):  
T. Atasever ◽  
A. Özdemir ◽  
I. Öznur ◽  
N. I. Karabacak ◽  
N. Gökçora ◽  
...  

Summary Aim: Our goal was to determine the clinical usefulness of TI-201 to identify breast cancer in patients with suspicious breast lesions on clinical examination, and/or abnormal radiologic (mammography and/or ultrasonography) findings. Methods: TI-201 scintigraphy were performed in sixty-eight patients with 70 breast abnormalities (51 palpable, 19 nonpalpable) and compared with mammography and ultrasonography (US). Early (15 min) and late (3 h) images of the breasts were obtained following the injection of 111 MBq (3 mCi) of TI-201. Visual and semiquantitative interpretation was performed. Results: Final diagnosis confirmed 52 malignant breast lesions and 18 benign conditions. TI-201 visualized 47 of 52 (90%) overall malignant lesions. Thirty-eight of 40 (95%) palpable and 9 of 12 (75%) nonpalpable breast cancers were detected by TI-201 scintigraphy. The smallest mass lesion detected by TI-201 measured 1.5x1.0 cm. Eleven breast lesions were interpreted as indeterminate by mammography and/or sonography. TI-201 scintigraphy excluded malignancy in 7 of 8 (88%) patients with benign breast lesions interpreted as indeterminate. Five of the 18 (28%) benign breast lesions showed TI-201 uptake. None of the fibroadenoma and fibrocystic changes accumulated TI-201. TI-201 scintigraphy, mammography and ultrasonography showed 90%, 92%, 85% overall sensitivity and 72%, 56%, 61% overall specificity respectively. Twenty-one of the 28 (75%) axillary nodal metastatic sites were also detected by TI-201. In malignant and benign lesions, early and late lesion/contralateral normal side (L/N) ratios were 1.58 ± 0.38 (mean ± SD) and 1.48 ± 0.32 (p >0.05), 1.87 ± 0.65 and 1.34 ± 0.20 (p<0.05) respectively. The mean early and late L/N ratios of malignant and benign groups did not show statistical difference (p>0.05). Conclusion: Overall, TI-201 scintigraphy was the most specific of the three methods and yielded favourable results in palpable breast cancers, while it showed lower sensitivity in nonpalpable cancers and axillary metastases. Combined use of TI-201 scintigraphy with mammography and US seems to be useful in difficult cases, such as dense breasts and indeterminate breast lesions.


Sign in / Sign up

Export Citation Format

Share Document