Safety of posterior chamber phakic intraocular lenses for the correction of high myopia

Ophthalmology ◽  
2001 ◽  
Vol 108 (1) ◽  
pp. 90-99 ◽  
Author(s):  
Ignacio Jiménez-Alfaro ◽  
José M Benı́tez del Castillo ◽  
Julian Garcı́a-Feijoó ◽  
Javier G Gil de Bernabé ◽  
José M Serrano de la Iglesia
2001 ◽  
Vol 17 (1) ◽  
pp. 32-42 ◽  
Author(s):  
José L Menezo ◽  
Cristina Peris-Martínez ◽  
Angel Cisneros ◽  
Rafael Martínez-Costa

2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Juan Gros-Otero ◽  
Samira Ketabi ◽  
Rafael Cañones-Zafra ◽  
Montserrat Garcia-Gonzalez ◽  
Cesar Villa-Collar ◽  
...  

Abstract Background To compare the anterior surface roughness of two commercially available posterior chamber phakic intraocular lenses (IOLs) using atomic force microscopy (AFM). Methods Four phakic IOLs were used for this prospective, experimental study: two Visian ICL EVO+ V5 lenses and two iPCL 2.0 lenses. All of them were brand new, were not previously implanted in humans, were monofocal and had a dioptric power of − 12 diopters (D). The anterior surface roughness was assessed using a JPK NanoWizard II® atomic force microscope in contact mode immersed in liquid. Olympus OMCL-RC800PSA commercial silicon nitride cantilever tips were used. Anterior surface roughness measurements were made in 7 areas of 10 × 10 μm at 512 × 512 point resolution. The roughness was measured using the root-mean-square (RMS) value within the given regions. Results The mean of all anterior surface roughness measurements was 6.09 ± 1.33 nm (nm) in the Visian ICL EVO+ V5 and 3.49 ± 0.41 nm in the iPCL 2.0 (p = 0.001). Conclusion In the current study, we found a statistically significant smoother anterior surface in the iPCL 2.0 phakic intraocular lenses compared with the VISIAN ICL EVO+ V5 lenses when studied with atomic force microscopy.


2016 ◽  
Vol 32 (6) ◽  
pp. 725-733 ◽  
Author(s):  
Maja Bohac ◽  
Marija Anticic ◽  
Natasa Draca ◽  
Bojan Kozomara ◽  
Iva Dekaris ◽  
...  

2004 ◽  
Vol 30 (1) ◽  
pp. 33-44 ◽  
Author(s):  
José L Menezo ◽  
Cristina Peris-Martínez ◽  
Angel L Cisneros ◽  
Rafael Martínez-Costa

2021 ◽  
Vol 14 (1) ◽  
pp. 61-64
Author(s):  
G. V. Sorokoletov ◽  
E. R. Tumanyan ◽  
A. N. Bessarabov ◽  
M. A. Soboleva

To date, the operation of choice in young patients with high myopia, is the implantation of posterior chamber phakic intraocular lenses (PIOL), provided that there are contraindications to keratorefractive interventions, However, in the late postoperative period, cataracts may occur, which requires the development of surgical tactics for lens explantation with simultaneous phacoemulsification of cataract (FEC) implementation.The purpose is to develop and analyze a method for removing a PIOL through a 2 mm corneal incision in subcapsular cataract cases.Material and methods. Posterior chamber domestic models of PIOL type RSK-1(3) and RSK-3 in 22 patients (37 eyes), implanted in the S.N. FEDOROV “EYE MICROSURGERY” clinic in 1994 – 2001 had to be removed due to the development of secondary cataracts. PIOL stayed in the eye 2 to 26 years (averagely 14.30 ± 1.30 yrs). In all cases, the P IOL was removed followed by FEC with implantation of a posterior chamber IOL. The optical power of the IOL was calculated mainly in such a way that the residual myopic refraction was 2.0–3.0 D.Results. The intraoperative condition of the anterior chamber was stable, the volume of irrigation fluid consumed was within 90–120 ml. No complications were detected in the early and late postoperative periods. The results of dynamic ophthalmological follow up of patients showed that visual acuity without correction and with correction after surgery averaged 0.2 ± 0.1 and 0.60 ± 0.15, respectively.Conclusion. The proposed method of explantation of domestic lenses of S.N. FEDOROV NMRC MNTK “EYE MICROSURGERY” shows that it enables a safe, simple removal of PIOL in the event of secondary subcapsular cataract, which allows achieving high clinical and functional results without overspending the irrigation solution.


Sign in / Sign up

Export Citation Format

Share Document