scholarly journals Atomic force microscopy comparative analysis of the surface roughness of two posterior chamber phakic intraocular lens models: ICL versus IPCL

2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Juan Gros-Otero ◽  
Samira Ketabi ◽  
Rafael Cañones-Zafra ◽  
Montserrat Garcia-Gonzalez ◽  
Cesar Villa-Collar ◽  
...  

Abstract Background To compare the anterior surface roughness of two commercially available posterior chamber phakic intraocular lenses (IOLs) using atomic force microscopy (AFM). Methods Four phakic IOLs were used for this prospective, experimental study: two Visian ICL EVO+ V5 lenses and two iPCL 2.0 lenses. All of them were brand new, were not previously implanted in humans, were monofocal and had a dioptric power of − 12 diopters (D). The anterior surface roughness was assessed using a JPK NanoWizard II® atomic force microscope in contact mode immersed in liquid. Olympus OMCL-RC800PSA commercial silicon nitride cantilever tips were used. Anterior surface roughness measurements were made in 7 areas of 10 × 10 μm at 512 × 512 point resolution. The roughness was measured using the root-mean-square (RMS) value within the given regions. Results The mean of all anterior surface roughness measurements was 6.09 ± 1.33 nm (nm) in the Visian ICL EVO+ V5 and 3.49 ± 0.41 nm in the iPCL 2.0 (p = 0.001). Conclusion In the current study, we found a statistically significant smoother anterior surface in the iPCL 2.0 phakic intraocular lenses compared with the VISIAN ICL EVO+ V5 lenses when studied with atomic force microscopy.

Author(s):  
H. Kinney ◽  
M.L. Occelli ◽  
S.A.C. Gould

For this study we have used a contact mode atomic force microscope (AFM) to study to topography of fluidized cracking catalysts (FCC), before and after contamination with 5% vanadium. We selected the AFM because of its ability to well characterize the surface roughness of materials down to the atomic level. It is believed that the cracking in the FCCs occurs mainly on the catalysts top 10-15 μm suggesting that the surface corrugation could play a key role in the FCCs microactivity properties. To test this hypothesis, we chose vanadium as a contaminate because this metal is capable of irreversibly destroying the FCC crystallinity as well as it microporous structure. In addition, we wanted to examine the extent to which steaming affects the vanadium contaminated FCC. Using the AFM, we measured the surface roughness of FCCs, before and after contamination and after steaming.We obtained our FCC (GRZ-1) from Davison. The FCC is generated so that it contains and estimated 35% rare earth exchaged zeolite Y, 50% kaolin and 15% binder.


2020 ◽  
Vol 46 (3) ◽  
pp. 491-491
Author(s):  
Miguel A. Teus ◽  
Montserrat Garcia-Gonzalez ◽  
Juan Gros-Otero ◽  
Rafael Cañones-Zafra

2002 ◽  
Vol 8 (5) ◽  
pp. 422-428 ◽  
Author(s):  
L.Y. Beaulieu ◽  
A.D. Rutenberg ◽  
J.R. Dahn

Measuring the changing thickness of a thin film, without a reference, using an atomic force microscope (AFM) is problematic. Here, we report a method for measuring film thickness based on in situ monitoring of surface roughness of films as their thickness changes. For example, in situ AFM roughness measurements have been performed on alloy film electrodes on rigid substrates as they react with lithium electrochemically. The addition (or removal) of lithium to (or from) the alloy causes the latter to expand (or contract) reversibly in the direction perpendicular to the substrate and, in principle, the change in the overall height of these materials is directly proportional to the change in roughness. If the substrate on which the film is deposited is not perfectly smooth, a correction to the direct proportionality is needed and this is also discussed.


Author(s):  
Sergey V. Generalov ◽  
Pavel S. Erokhin ◽  
Oleg S. Kuznetsov ◽  
Elena G. Abramova ◽  
Ivan M. Zhulidov ◽  
...  

Background: Mouse neutralization test is widely used to determine the level of anti-rabies antibodies, but it is labor-intensive and time consuming. Alternative methods for determining the neutralizing activity of anti-rabies sera and immunoglobulin in cell cultures are also known. Methods such as FAVN and RFFIT involve the use of fluorescent diagnostics. Determination of Cytopathic Effect (CPE) is often complicated due to features of rabies virus replication in cells. Atomic Force Microscopy (AFM) is able to detect the interaction of the virus with the cell at an early stage. Therefore, in this study, a method has been developed for determining the specific activity of anti-rabies sera and immunoglobulin using AFM of cell cultures.   Methods: The method is based on the preliminary interaction of rabies virus with samples of rabies sera or immunoglobulin drug, adding the specified reaction mixture to cell culture (Vero or BHK-21), and then measuring the surface roughness of the cells using AFM. AFM was carried out in the intermittent contact mode by the mismatch method in the semi-contact mode. The results were compared with the values obtained in the mouse neutralization test. The consistency of the results obtained by both methods was evaluated by Bland-Altman method.   Results: The increment in the surface roughness of the cells is a consequence of the damaging effect of the virus, which is weakened as a result of its neutralization by rabies antibodies. A dilution allowing 50% suppression of the increase in the surface roughness of cells was selected as the titer of rabies sera or immunoglobulin. In this case, the recommended range for determining the antibody titer is from 1:100 to 1:3000.   Conclusion: For the first time, a new methodological approach in virology and pharmaceutical research is presented in this study. The use of the proposed methodological technique will reduce the time from 21 to 2 days to obtain results in comparison with the mouse neutralization test; also, fewer laboratory animals are required in this approach which is in agreement with 3 R Principle.


2010 ◽  
Vol 36 (9) ◽  
pp. 1573-1578 ◽  
Author(s):  
Marco Lombardo ◽  
Stefan Talu ◽  
Mihai Talu ◽  
Sebastiano Serrao ◽  
Pietro Ducoli

2020 ◽  
Author(s):  
Benjamin P. A. Gabriele ◽  
Craig J. Williams ◽  
Douglas Stauffer ◽  
Brian Derby ◽  
Aurora J. Cruz-Cabeza

<div> <div> <div> <p>Single crystals of aspirin form I were cleaved and indented on their dominant face. Upon inspection, it was possible to observe strongly anisotropic shallow lateral cracks due to the extreme low surface roughness after cleavage. Atomic Force Microscopy (AFM) imaging showed spalling fractures nucleating from the indent corners, forming terraces with a height of one or two interplanar spacings d100. The formation of such spalling fractures in aspirin was rationalised using basic calculations of attachment energies, showing how (100) layers are poorly bonded when compared to their relatively higher intralayer bonding. An attempt at explaining the preferential propagation of these fractures along the [010] direction is discussed. </p> </div> </div> </div>


2020 ◽  
Author(s):  
Benjamin P. A. Gabriele ◽  
Craig J. Williams ◽  
Douglas Stauffer ◽  
Brian Derby ◽  
Aurora J. Cruz-Cabeza

<div> <div> <div> <p>Single crystals of aspirin form I were cleaved and indented on their dominant face. Upon inspection, it was possible to observe strongly anisotropic shallow lateral cracks due to the extreme low surface roughness after cleavage. Atomic Force Microscopy (AFM) imaging showed spalling fractures nucleating from the indent corners, forming terraces with a height of one or two interplanar spacings d100. The formation of such spalling fractures in aspirin was rationalised using basic calculations of attachment energies, showing how (100) layers are poorly bonded when compared to their relatively higher intralayer bonding. An attempt at explaining the preferential propagation of these fractures along the [010] direction is discussed. </p> </div> </div> </div>


Friction ◽  
2021 ◽  
Author(s):  
Xinfeng Tan ◽  
Dan Guo ◽  
Jianbin Luo

AbstractDynamic friction occurs not only between two contact objects sliding against each other, but also between two relative sliding surfaces several nanometres apart. Many emerging micro- and nano-mechanical systems that promise new applications in sensors or information technology may suffer or benefit from noncontact friction. Herein we demonstrate the distance-dependent friction energy dissipation between the tip and the heterogeneous polymers by the bimodal atomic force microscopy (AFM) method driving the second order flexural and the first order torsional vibration simultaneously. The pull-in problem caused by the attractive force is avoided, and the friction dissipation can be imaged near the surface. The friction dissipation coefficient concept is proposed and three different contact states are determined from phase and energy dissipation curves. Image contrast is enhanced in the intermediate setpoint region. The work offers an effective method for directly detecting the friction dissipation and high resolution images, which overcomes the disadvantages of existing methods such as contact mode AFM or other contact friction and wear measuring instruments.


Sign in / Sign up

Export Citation Format

Share Document