PO-1787 The Effect of Reducing CT Dose on Proton Therapy Dose Calculation – Phantom Study

2021 ◽  
Vol 161 ◽  
pp. S1512-S1513
Author(s):  
M. Elhamiasl ◽  
K. Salvo ◽  
E. Sterpin ◽  
J. Nuyts
2021 ◽  
Author(s):  
Xiaoke Zhang ◽  
Zongsheng Hu ◽  
Guoliang Zhang ◽  
Yongdong Zhuang ◽  
Yuenan Wang ◽  
...  

2020 ◽  
Vol 152 ◽  
pp. S124
Author(s):  
G. Fonseca ◽  
I. Almeida ◽  
T. Wagenberg ◽  
C. Wolfs ◽  
G. Vilches Freixas ◽  
...  

2021 ◽  
Vol 32 (1) ◽  
pp. 18-24
Author(s):  
Hosang Jeon ◽  
Dong Woon Kim ◽  
Ji Hyeon Joo ◽  
Yongkan Ki ◽  
Wontaek Kim ◽  
...  

2021 ◽  
Vol 20 ◽  
pp. 153303382110330
Author(s):  
Chunbo Liu ◽  
Meng Wei Ho ◽  
Jiyeon Park ◽  
Wen Chien Hsi ◽  
Xiaoying Liang ◽  
...  

Purpose: To commission MCsquare (a multi-cores CPU-based dose calculation engine) for pencil beam scanning (PBS) proton therapy, integrate it into RayStation treatment plan system (TPS) to create a dedicated platform for fast independent dose verification. Method: A MCsquare-based independent dose verification platform (MC2InRS) was developed to realize automatic dose re-calculation for clinical use, including data preparation, dose calculation, 2D/3D gamma analysis. MCsquare was commissioned based on in-air lateral dose profiles, integrated depth dose, and the absolute dose of different beam energies for Proteus®ONE. MC2InRS was validated with measurement data using various targets and depths in a water phantom. This study also investigated 15 clinical cases to demonstrate the feasibility and effectiveness of MC2InRS platform in clinic practice. Results: Between simulation and measurement, the distal range differences at 80% (R80) and 20% (R20) dose levels for each energy were below 0.05 mm, and 0.1 mm, respectively, and the absolute dose differences were below 0.5%. 29 out of 36 QA planes reached a 100% gamma passing rate (GPR) for 2%/2mm criteria, and a minimum of 98.3% gamma was obtained in water phantom between simulation and measurement. For the 15 clinical cases investigated, the average 2D GPR (2%/2mm) was 95.4%, 99.3% for MCsquare vs. measurement, MCsquare vs. TPS, respectively. The average 3D GPR (2%/2mm) was 98.9%, 95.3% for MCsquare vs. TPS in water, and computed tomography (CT), respectively. Conclusion: MC2InRS, a fast, independent dose verification platform, has been developed to perform dose verification with high accuracy and efficiency for Pencil Bream Scanning (PBS). Its potential to be applied in routine clinical practice has also been discussed.


2018 ◽  
Vol 52 ◽  
pp. 81
Author(s):  
Alessio Boschini ◽  
Lucia Riccardi ◽  
Francesca De Monte ◽  
Roberto Zandonà ◽  
Marta Paiusco
Keyword(s):  

2012 ◽  
Vol 57 (11) ◽  
pp. 3281-3293 ◽  
Author(s):  
J Schümann ◽  
H Paganetti ◽  
J Shin ◽  
B Faddegon ◽  
J Perl

2011 ◽  
Vol 38 (6Part22) ◽  
pp. 3656-3656
Author(s):  
Y Egashira ◽  
T Nishio ◽  
T Matsuura ◽  
S Kameoka ◽  
M Uesaka

Sign in / Sign up

Export Citation Format

Share Document