TU-A-12A-07: CT-Based Biomarkers to Characterize Lung Lesion: Effects of CT Dose, Slice Thickness and Reconstruction Algorithm Based Upon a Phantom Study

2014 ◽  
Vol 41 (6Part26) ◽  
pp. 451-451
Author(s):  
B Zhao ◽  
Y Tan ◽  
W Tsai ◽  
L Lu ◽  
L Schwartz ◽  
...  
2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Robert Peter Reimer ◽  
Konstantin Klein ◽  
Miriam Rinneburger ◽  
David Zopfs ◽  
Simon Lennartz ◽  
...  

AbstractComputed tomography in suspected urolithiasis provides information about the presence, location and size of stones. Particularly stone size is a key parameter in treatment decision; however, data on impact of reformatation and measurement strategies is sparse. This study aimed to investigate the influence of different image reformatations, slice thicknesses and window settings on stone size measurements. Reference stone sizes of 47 kidney stones representative for clinically encountered compositions were measured manually using a digital caliper (Man-M). Afterwards stones were placed in a 3D-printed, semi-anthropomorphic phantom, and scanned using a low dose protocol (CTDIvol 2 mGy). Images were reconstructed using hybrid-iterative and model-based iterative reconstruction algorithms (HIR, MBIR) with different slice thicknesses. Two independent readers measured largest stone diameter on axial (2 mm and 5 mm) and multiplanar reformatations (based upon 0.67 mm reconstructions) using different window settings (soft-tissue and bone). Statistics were conducted using ANOVA ± correction for multiple comparisons. Overall stone size in CT was underestimated compared to Man-M (8.8 ± 2.9 vs. 7.7 ± 2.7 mm, p < 0.05), yet closely correlated (r = 0.70). Reconstruction algorithm and slice thickness did not significantly impact measurements (p > 0.05), while image reformatations and window settings did (p < 0.05). CT measurements using multiplanar reformatation with a bone window setting showed closest agreement with Man-M (8.7 ± 3.1 vs. 8.8 ± 2.9 mm, p < 0.05, r = 0.83). Manual CT-based stone size measurements are most accurate using multiplanar image reformatation with a bone window setting, while measurements on axial planes with different slice thicknesses underestimate true stone size. Therefore, this procedure is recommended when impacting treatment decision.


2019 ◽  
Vol 37 (5) ◽  
pp. 399-411
Author(s):  
Yoshiharu Ohno ◽  
Yasuko Fujisawa ◽  
Kenji Fujii ◽  
Naoki Sugihara ◽  
Yuji Kishida ◽  
...  

2020 ◽  
Vol 101 (5) ◽  
pp. 289-297 ◽  
Author(s):  
J. Greffier ◽  
S. Boccalini ◽  
J.P. Beregi ◽  
A. Vlassenbroek ◽  
A. Vuillod ◽  
...  

2017 ◽  
Vol 44 (4) ◽  
pp. 1514-1524 ◽  
Author(s):  
Rebecca M. Marsh ◽  
Michael S. Silosky

2021 ◽  
Vol 161 ◽  
pp. S1512-S1513
Author(s):  
M. Elhamiasl ◽  
K. Salvo ◽  
E. Sterpin ◽  
J. Nuyts

2005 ◽  
Vol 46 (3) ◽  
pp. 237-245 ◽  
Author(s):  
J. Vikgren ◽  
O. Friman ◽  
M. Borga ◽  
M. Boijsen ◽  
S. Gustavsson ◽  
...  

Purpose: To assess the ability of a conventional density mask method to detect mild emphysema by high‐resolution computed tomography (HRCT); to analyze factors influencing quantification of mild emphysema; and to validate a new algorithm for detection of mild emphysema. Material and Methods: Fifty‐five healthy male smokers and 34 never‐smokers, 61–62 years of age, were examined. Emphysema was evaluated visually, by the conventional density mask method, and by a new algorithm compensating for the effects of gravity and artifacts due to motion and the reconstruction algorithm. Effects of the reconstruction algorithm, slice thickness, and various threshold levels on the outcome of the density mask area were evaluated. Results: Forty‐nine percent of the smokers had mild emphysema. The density mask area was higher the thinner the slice irrespective of the reconstruction algorithm and threshold level. The sharp algorithm resulted in increased density mask area. The new reconstruction algorithm could discriminate between smokers with and those without mild emphysema, whereas the density mask method could not. The diagnostic ability of the new algorithm was dependent on lung level. At about 90% specificity, sensitivity was 65–100% in the apical levels, but low in the rest of the lung. Conclusion: The conventional density mask method is inadequate for detecting mild emphysema, while the new algorithm improves the diagnostic ability but is nevertheless still imperfect.


Sign in / Sign up

Export Citation Format

Share Document