Diffusion studies using ion beam analysis

Author(s):  
N Moncoffre ◽  
G Barbier ◽  
E Leblond ◽  
Ph Martin ◽  
H Jaffrezic
2020 ◽  
Vol 13 ◽  
pp. 51
Author(s):  
H.-W. Becker

The unique advantages of ion beam analysis, such as the depth resolved unam- biguous stoichometric information of RBS or the possibility to detect hydrogen with high depth resolution still opens new applications in fundamental as well as applied science. Two examples are presented here.The diffusion of hydrogen in cement during the formation of cement has been studied with the 15N hydrogen depth profiling. It could be shown, that the known stages of the hydration process are correlated with the diffusion of hydrogen on a nanometer scale.Diffusion processes play also an important role in geology. The investigation of such processes with RBS will be presented. Prospects of diffusion studies using isotopie tracing with low lying resonances will be discussed.


2019 ◽  
Vol 297 ◽  
pp. 100-110 ◽  
Author(s):  
Nick Lucas ◽  
Kelsey E. Seyfang ◽  
Andrew Plummer ◽  
Michael Cook ◽  
K. Paul Kirkbride ◽  
...  

Instruments ◽  
2021 ◽  
Vol 5 (1) ◽  
pp. 10
Author(s):  
Sören Möller ◽  
Daniel Höschen ◽  
Sina Kurth ◽  
Gerwin Esser ◽  
Albert Hiller ◽  
...  

The analysis of material composition by ion-beam analysis (IBA) is becoming a standard method, similar to electron microscopy. A pool of IBA methods exists, from which the combination of particle-induced-X-ray emission (PIXE), particle induced gamma-ray analysis (PIGE), nuclear-reaction-analysis (NRA), and Rutherford-backscattering-spectrometry (RBS) provides the most complete analysis over the whole periodic table in a single measurement. Yet, for a highly resolved and accurate IBA analysis, a sophisticated technical setup is required integrating the detectors, beam optics, and sample arrangement. A new end-station developed and installed in Forschungszentrum Jülich provides these capabilities in combination with high sample throughput and result accuracy. Mechanical tolerances limit the device accuracy to 3% for RBS. Continuous pumping enables 5*10−8 mbar base pressure with vibration amplitudes < 0.1 µm. The beam optics achieves a demagnification of 24–34, suitable for µ-beam analysis. An in-vacuum manipulator enables scanning 50 × 50 mm² sample areas with 10 nm accuracy. The setup features the above-mentioned IBA detectors, enabling a broad range of analysis applications such as the operando analysis of batteries or the post-mortem analysis of plasma-exposed samples with up to 3000 discrete points per day. Custom apertures and energy resolutions down to 11 keV enable separation of Fe and Cr in RBS. This work presents the technical solutions together with the quantification of these challenges and their success in the form of a technical reference.


Author(s):  
P. Wei ◽  
M. Chicoine ◽  
S. Gujrathi ◽  
F. Schiettekatte ◽  
J.-N. Beaudry ◽  
...  

1999 ◽  
Vol 12 (3) ◽  
pp. 457-467 ◽  
Author(s):  
Narayan Sundararajan ◽  
Christopher F. Keimel ◽  
Navin Bhargava ◽  
Christopher K. Ober ◽  
Juliann Opitz ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document