P2126 Intrinsic and paced QRS duration are predictive of the global clinical response to cardiac resynchronization therapy in patients with severe heart failure

2003 ◽  
Vol 24 (5) ◽  
pp. 397
Author(s):  
G LECOQ
Author(s):  
Mitsuo Sobajima ◽  
Nobuyuki Fukuda ◽  
Hiroshi Ueno ◽  
Koichiro Kinugawa

Abstract Background  The safety and efficacy of MitraClip for advanced heart failure (HF) patients who are inotrope-dependent or mechanically supported are unknown. Case summary  The patient was a 71-year-old man diagnosed as dilated cardiomyopathy in 2003. He was admitted due to worsening HF in January 2019 and became dependent upon intravenous infusion of inotropes. During the 8-month hospitalization, his haemodynamics were relatively static with bed rest and continuous inotropes, but he was definitely dependent on them. Our multidisciplinary team decided to perform both cardiac resynchronization therapy (CRT) and MitraClip under Impella support. First, Impella was inserted from left subclavian artery. After a week, CRT was implanted from right subclavian vein, and the QRS duration of electrocardiogram became remarkably narrow. MitraClip was performed 2 weeks after Impella, and functional mitral regurgitation improved from severe to mild, and Impella was removed on the same day. Inotropes could be ceased, and he was discharged 2 months after MitraClip. Discussion  During inotrope-dependent status, there was a risk that HF would worsen with haemodynamic collapse when performing CRT implantation, and we firstly supported his haemodynamics by Impella. Cardiac resynchronization therapy implantation before MitraClip seemed to be crucial. In fact, the mitral valve morphology before Impella insertion had very poor coaptation of the anterior and posterior leaflets that was not optimal for MitraClip procedure. But the Impella support and correction of dyssynchrony by CRT markedly improved the coaptation of those leaflets. The combination therapy of CRT and MitraClip unloading with Impella maybe a new therapeutic option for advanced HF.


2015 ◽  
Vol 1 (1) ◽  
pp. 89-91 ◽  
Author(s):  
J. Tumampos ◽  
N. Wulf ◽  
H. Kühnert ◽  
O. Solbrig ◽  
J. Querengässer ◽  
...  

AbstractCardiac resynchronization therapy (CRT) is an established therapy for heart failure patients and improves quality of life in patients with sinus rhythm, reduced left ventricular ejection fraction (LVEF), left bundle branch block and wide QRS duration. Since approximately sixty percent of heart failure patients have a normal QRS duration they do not benefit or respond to the CRT. Cardiac contractility modulation (CCM) releases nonexcitatoy impulses during the absolute refractory period in order to enhance the strength of the left ventricular contraction. The aim of the investigation was to evaluate differences in cardiac index between optimized and nonoptimized CRT and CCM devices versus standard values. Impedance cardiography, a noninvasive method was used to measure cardiac index (CI), a useful parameter which describes the blood volume during one minutes heart pumps related to the body surface. CRT patients indicate an increase of 39.74 percent and CCM patients an improvement of 21.89 percent more cardiac index with an optimized device.


Sign in / Sign up

Export Citation Format

Share Document