scholarly journals ANTIMICROBIAL SUSCEPTIBILITY TESTING OF HELICOBACTER PYLORI TO SELECTED AGENTS BY AGAR DILUTION METHOD IN SHIRAZ-IRAN

2007 ◽  
Vol 25 (4) ◽  
pp. 374-377
Author(s):  
J Kohanteb ◽  
A Bazargani ◽  
M Saberi-Firoozi ◽  
A Mobasser
Antibiotics ◽  
2021 ◽  
Vol 10 (8) ◽  
pp. 975
Author(s):  
Florian Baquer ◽  
Asma Ali Sawan ◽  
Michel Auzou ◽  
Antoine Grillon ◽  
Benoît Jaulhac ◽  
...  

Antimicrobial susceptibility testing of anaerobes is challenging. Because MIC determination is recommended by both CLSI and EUCAST, commercial broth microdilution and diffusion strip tests have been developed. The reliability of broth microdilution methods has not been assessed yet using the agar dilution reference method. In this work, we evaluated two broth microdilution kits (MICRONAUT-S Anaerobes® MIC and Sensititre Anaerobe MIC®) and one gradient diffusion strip method (Liofilchem®) for antimicrobial susceptibility testing of 47 Clostridiales isolates (Clostridium, Clostridioides and Hungatella species) using the agar dilution method as a reference. The evaluation focused on comparing six antimicrobial molecules available in both microdilution kits. Analytical performances were evaluated according to the Food and Drug Administration (FDA) recommendations. Essential agreements (EA) and categorical agreements (CA) varied greatly according to the molecule and the evaluated method. Vancomycin had values of essential and categorical agreements above 90% for the three methods. The CA fulfilled the FDA criteria for three major molecules in the treatment of Gram-positive anaerobic infections (metronidazole, piperacillin/tazobactam and vancomycin). The highest rate of error was observed for clindamycin. Multicenter studies are needed to further validate these results.


1998 ◽  
Vol 36 (9) ◽  
pp. 2784-2785 ◽  
Author(s):  
Yanet Valdez ◽  
Billie Velapatiño ◽  
Robert H. Gilman ◽  
Vilma Gutierrez ◽  
Carlos León

Metronidazole and tetracycline E tests were compared to an agar dilution method for the antimicrobial susceptibility testing ofHelicobacter pylori. Sixteen strains were tested by using tetrazolium egg yolk (TEY) agar. The characteristic E test inhibition ellipse was clearer on TEY agar than on standard blood agar and gave results comparable to those of the agar dilution test. The use of TEY medium is preferable to that of blood agar medium in E test MIC determinations for H. pylori.


2004 ◽  
Vol 53 (12) ◽  
pp. 1229-1232 ◽  
Author(s):  
Intetsu Kobayashi ◽  
Hiroe Muraoka ◽  
Takako Iyoda ◽  
Minoru Nishida ◽  
Miyuki Hasegawa ◽  
...  

We evaluated the automated VITEK 2 system (bioMérieux) for antimicrobial susceptibility testing of vancomycin-resistant Enterococcus (VRE). The results obtained with the VITEK 2 system were compared to those obtained using two NCCLS reference methods. The VITEK 2 system produced MICs for penicillin G, erythromycin and vancomycin that were very similar to those of the reference agar-dilution test with all results being within a twofold dilution. When MICs of teicoplanin for these isolates were measured by the agar-dilution method and VITEK 2 system, there was one ‘very major’ error and seven ‘minor’ errors. There were no ‘major’ errors for any of the antibiotics tested. When the results obtained by the micro broth-dilution method were compared with those obtained by the VITEK 2 system, there was one ‘very major’ error for teicoplanin by the VITEK 2 system, as was the case with the agar-dilution method. There were two ‘minor’ errors for erythromycin and seven ‘minor’ errors for teicoplanin. There were no ‘major’ errors for any of the antibiotics tested. The 35 VRE strains identified phenotypically by the VITEK 2 Advanced Expert System included nine of Enterococcus faecalis and 23 of Enterococcus faecium. Neither Enterococcus avium nor Enterococcus hirae were identified. A total of 32 phenotypes were classified into 22 VanA and 10 VanB strains. PCR genotyping demonstrated 23 vanA + and nine vanB + strains. There were differences between the VITEK 2 system results and those of PCR. Overall, 54.3 % of the test results were obtained within 7 h. All MIC values for the 35 VRE isolates were determined within 13 h of completing incubation. The VITEK 2 system is a simple method for accurately detecting vancomycin-resistant strains of Enterococcus and can be used to rapidly determine MICs.


Sign in / Sign up

Export Citation Format

Share Document