Optimization of Artificial Wetland Design for Removal of Indicator Microorganisms and Pathogenic Protozoa

1999 ◽  
Vol 40 (4-5) ◽  
1999 ◽  
Vol 40 (4-5) ◽  
pp. 363-368 ◽  
Author(s):  
C. P. Gerba ◽  
J. A. Thurston ◽  
J. A. Falabi ◽  
P. M. Watt ◽  
M. M. Karpiscak

The enhancement of water quality by artificial wetland systems is increasingly being employed throughout the world. Three wetlands were studied in Tucson, AZ to evaluate their individual performance in the removal of indicator bacteria (coliforms), coliphage, and enteric pathogens (Giardia and Cryptosporidium). A duckweed-covered pond, a multi-species subsurface flow (SSF) and a multi-species surface flow (SF) wetland were studied. Removal of the larger microorganisms, Giardia and Cryptosporidium, was the greatest in the duckweed pond at 98 and 89 percent, respectively. The lowest removal occurred in the SF wetland, 73 percent for Giardia and 58 percent removal for Cryptosporidium. In contrast, the greatest removal of coliphage, total and fecal coliforms occurred in the SSF wetland, 95, 99, and 98 percent respectively, whereas the pond had the lowest removals (40, 62, and 61 percent, respectively). Sedimentation may be the primary removal mechanism within the duckweed pond since the removal was related to size, removal of the largest organisms being the greatest. However, the smaller microorganisms were removed more efficiently in the SSF wetland, which may be related to the large surface area available for adsorption and filtration. This study suggests that in order to achieve the highest treatment level of secondary unchlorinated wastewater, a combination of aquatic ponds and subsurface flow wetlands may be necessary.


1993 ◽  
Vol 27 (7-8) ◽  
pp. 287-294 ◽  
Author(s):  
S. Lerman ◽  
O. Lev ◽  
A. Adin ◽  
E. Katzenelson

The Israel Ministry of Health is now revising its regulations for the assurance of safe water quality in public swimming pools. Since it is not possible to monitor each of the pathogenic microorganisms, it is often recommended to monitor indicator bacteria which provide indirect information on the water quality in the swimming pool. Three indicator microorganisms are often recommended: coliform counts (total coliforms, fecal coliforms or E. Coli), staphylococcus aureus and pseudomonas aeruginosa. A four year survey of the water quality of swimming pools in the Jerusalem District was conducted in order to determine whether the monitoring of all three indicators is necessary to assure safe water quality or is it sufficient to monitor only a single microorganism. A statistical analysis, conducted by using several different statistical techniques, reveals that the populations of the three indicator organisms are significantly interdependent but the correlations between each pair of these indicators are not sufficient to base a prediction of any of the organisms based on the measurements of the others. Therefore, it is concluded that monitoring of all three indicators should be recommended in order to provide an adequate picture of the water quality in swimming pools.


1996 ◽  
Vol 33 (4-5) ◽  
pp. 309-313
Author(s):  
Jan Šálek ◽  
František Marcián ◽  
Iman Elazizy

Vegetative root zone methods are based on self-purifying processes that take place in the soil, wetland and vegetation containing water media. Our studies are concentrated on the course of puryfying in relation with the length of the filtration bed and on the progress of eliminating the ammoniacal pollution. The research proved that the essential part of the puryfying process takes place within the inlet zone (Figs 1 and 2). The decomposition of ammonia proceeds very slowly. The process of nitrification is affected by the lack of oxygen in the filtration media. To improve the effectiveness of vegetative root zone methods we suggest specific steps: an adjustment of the inlet zone, a system of cascades, a water level pulsation system and combinations of different types and arrangements of vegetative root zones.


2019 ◽  
Vol 208 ◽  
pp. 649-655 ◽  
Author(s):  
Shibao Lu ◽  
Xuerui Gao ◽  
Pute Wu ◽  
Wei Li ◽  
Xiao Bai ◽  
...  

2006 ◽  
Vol 15 (4) ◽  
pp. 589-596 ◽  
Author(s):  
J. Cucherousset ◽  
J.-M. Paillisson ◽  
A. Carpentier ◽  
M.-C. Eybert ◽  
J. D. Olden

2010 ◽  
Vol 36 (3) ◽  
pp. 229-235 ◽  
Author(s):  
Geun-Yeol Lee ◽  
Keun-Ha Kim ◽  
Mun-Ju Kwon ◽  
Hyuk-Ku Kwon ◽  
Yeon-Hee Kim ◽  
...  

Author(s):  
Pasionaria R Ramos-Ruiz Díaz ◽  
Lorena M García-Cespedes ◽  
Ximena M García-Reyes ◽  
Lucas K González-Albavi ◽  
Lisa Sarquis ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document