Heat transfer coefficients between gas fluidized beds and immersed spheres: dependence on the sphere size

1996 ◽  
Vol 22 ◽  
pp. 142
Author(s):  
G Donsi
1999 ◽  
Author(s):  
Kal R. Sharma

Abstract Experimentally measured values for the minimum fluidization velocities and time averaged local surface heat transfer coefficients are provided for 16 different cases of fluidizing conditions for gas-solid dense fluidized beds. Semi-empirical Correlations for the minimum fluidization velocity and the heat transfer coefficient at minimum fluidization velocities are provided. The implications of the Peclet number dependence in terms of diffusion and convection is discussed.


2019 ◽  
Vol 128 ◽  
pp. 01003 ◽  
Author(s):  
Jaroslaw Krzywanski ◽  
Karolina Grabowska ◽  
Marcin Sosnowski ◽  
Anna Zylka ◽  
Anna Kulakowska ◽  
...  

An innovative idea, shown in the paper constitutes in the use of the fluidized bed of sorbent, instead of the conventional, fixed-bed, commonly used in the adsorption chillers. Bed–to–wall heat transfer coefficients for fixed and fluidized beds of adsorbent are determined. Sorbent particles diameters and velocities of fluidizing gas are discussed in the study. The calculations confirmed, that the bed–to–wall heat transfer coefficient in the fluidized bed of adsorbent is muchhigher than that in a conventional bed.


1980 ◽  
Vol 102 (1) ◽  
pp. 152-157 ◽  
Author(s):  
R. Chandran ◽  
J. C. Chen ◽  
F. W. Staub

The local characteristics of heat transfer from horizontal tubes immersed in fluidized beds were investigated experimentally. Steady-state heat transfer measurements were obtained in air-fluidized beds of glass beads, both for a single tube and a ten-row bare tube bundle. The test results indicated that local heat transfer coefficients are strongly influenced by angular position and gas flow rate, as well as by particle size and system pressure. The heat transfer coefficients, averaged around the circumference of the tube, exhibited a general tendency to increase with decreasing particle size and increasing system pressure. The heat transfer coefficients for a tube in an inner-row position within the bundle were found to be slightly higher than those for a tube in the bottom-row. Comparison of the average heat transfer coefficient data obtained in this study with some of the existing correlations for heat transfer from horizontal tubes showed that the correlations are unsatisfactory.


Sign in / Sign up

Export Citation Format

Share Document