scholarly journals Oxygen uptake efficiency slope: A new index of cardiorespiratory functional reserve derived from the relation between oxygen uptake and minute ventilation during incremental exercise

1996 ◽  
Vol 28 (6) ◽  
pp. 1567-1572 ◽  
Author(s):  
Reizo Baba ◽  
Masami Nagashima ◽  
Masahiko Goto ◽  
Yoshiko Nagano ◽  
Mitsuhiro Yokota ◽  
...  
2007 ◽  
Vol 13 (6) ◽  
pp. 462-469 ◽  
Author(s):  
Ross Arena ◽  
Jonathan Myers ◽  
Leon Hsu ◽  
Mary Ann Peberdy ◽  
Sherry Pinkstaff ◽  
...  

Author(s):  
Christophe Van Laethem ◽  
Johan De Sutter ◽  
Wim Peersman ◽  
Patrick Calders

Background The oxygen uptake efficiency slope (OUES) is a newer ventilatory exercise parameter, used in the evaluation of healthy participants and patients with cardiovascular disease. However, few data about the reliability and reproducibility of OUES are available. Our study assessed intratest reliability and test-retest reproducibility of OUES in healthy participants. Design and methods Eighteen participants (age 28 ± 6 years, BMI 22.1 ± 1.9 kg/m2, 10 men) performed two identical maximal exercise tests on a bicycle ergometer. To assess test-retest reproducibility, we performed Bland-Altman analysis and calculated the coefficient of repeatability of the main ventilatory variables. Results OUES remained stable during the second part of the exercise test. Mean values varied 2.4 ± 4.0% between OUES calculated at 70% (OUES70) and at 100% of exercise duration. Mean variation decreased to 1.4 ± 2.3% when OUES was calculated at 90% of exercise duration (OUES90). The Bland-Altman 95% limits of agreement for OUES90 were +3 and –6%, those for OUES70 were +11 and –8%. The coefficient of repeatability for OUES was 597 ml/min or 18.7% of the average value of repeated OUES measurements. These results were similar to those of peak oxygen uptake and minute ventilation/carbon dioxide output. However, the test-retest reproducibility for submaximal-derived values of OUES was lower, as we noted higher coefficients of repeatability for OUES90 and OUES70, increasing up to 27% of the average of repeated values. Conclusion OUES shows excellent intratest reliability and has a test-retest reproducibility that is similar to that of peak oxygen uptake and minute ventilation/carbon dioxide output slope. However, its reproducibility becomes higher when it is calculated from increasing levels of achieved exercise intensity.


2002 ◽  
Vol 27 (6) ◽  
pp. 589-601 ◽  
Author(s):  
Aurélien Pichon ◽  
Sophie Jonville ◽  
André Denjean

A reliable submaximal test for assessing cardiorespiratory function would be of interest in clinical practice. Baba et al. (1996) proposed the oxygen uptake efficiency slope (OUES) derived from the relation between oxygen uptake ([Formula: see text] and minute ventilation [Formula: see text] during incremental exercise. We evaluated the validity of OUES by comparing maximal oxygen uptake [Formula: see text] predicted from OUES to measured [Formula: see text] in 50 healthy males who performed a maximal treadmill test. They had widely differing physical fitness levels ([Formula: see text]range, 32.7 to 80.2 mlO2 ∙ min−1 ∙ kg−1). Predicted [Formula: see text] was not significantly different (p > 0.99) from measured [Formula: see text] (56.8 ± 7.0 vs. 56.8 ± 8.8 mlO2 ∙ min−1 ∙ kg−1). The limits of agreement (Bland & Altman, 1986) were plus or minus 10.5 mlO2 ∙ min−1 ∙ kg−1. Although OUES and [Formula: see text]were significantly correlated (r = 0.79), the wide interindividual variations in the difference between these two parameters may limit the usefulness of OUES in clinical practice. Key Words: exercise, testing, OUES, fitness, agreement