scholarly journals Stripping the long saphenous vein reduces the rate of reoperation for recurrent varicose veins: Five-year results of a randomized trial

1999 ◽  
Vol 29 (4) ◽  
pp. 589-592 ◽  
Author(s):  
Simon Dwerryhouse ◽  
Birgit Davies ◽  
Kate Harradine ◽  
Jonathan J. Earnshaw
Phlebologie ◽  
2000 ◽  
Vol 29 (03) ◽  
pp. 58-61 ◽  
Author(s):  
G. Madycki ◽  
P. Dabek ◽  
A. Gabrusiewicz ◽  
W. Staszkiewicz

SummaryAim: Authors performed a retrospective analysis of causes of recurrent varicose veins following surgery. Methods: They evaluated 89 patients (65 women and 24 men, mean age 49.7 years). All patients previously underwent same surgical procedures (long saphenous vein stripping with/without local multiple avulsions). For the purpose of the study, colour/duplex examinations were applied (Siemens Sonoline Elegra unit). Results: Depending on the type and area of recurrent varicose veins, patients were classified into 4 groups. Group I – 22 patients (persistence of varicose tributaries of LSV in thigh or thigh perforator). Group II – 27 patients (recurrence along the LSV in the calf). Group III – 26 patients (recurrence due to left incompetent short saphenous vein). Group IV – 14 patients (isolated incompetent perforators). Authors conclude, that colour-coded duplex scanning is currently a method of choice in the diagnosis of recurrent varicose veins. High incidence of recurrence due to short saphenous vein incompetence should draw particular attention to this vein in the preoperative assessment of venous system. Recurrence of varicose veins at thigh level is not caused by deep vein insufficiency, but is related to inadequate vein surgery or might be linked to the problem of neovascularisation in this area.


1996 ◽  
Vol 11 (3) ◽  
pp. 125-131 ◽  
Author(s):  
K. A. Myers ◽  
G. H. Zeng ◽  
R. W. Ziegenbein ◽  
P. G. Matthews

Objective: To use duplex ultrasound scanning to compare limbs with recurrent and primary varicose veins and to identify connections between deep veins and recurrences. Setting: A non-invasive vascular laboratory in Melbourne, Australia. Patients: A study of 779 limbs with recurrent varicose veins previously treated by ligation or stripping of the long saphenous vein and 1521 limbs with primary varicose veins. Main outcome measures: Connections between deep veins and recurrent varices, reflux in superficial and deep veins, and outward flow in perforators as demonstrated by duplex ultrasonography. Results: Recurrence was due to reflux in the long saphenous territory in 71.8%, short saphenous reflux alone in 14.7% or outward flow in calf perforators without saphenous reflux in 5.2%, while no source was detected in 8.3%. Limbs with recurrent veins in the long saphenous territory were compared with limbs with primary varicose veins; there was more frequent outward flow in thigh perforators (25.2% vs. 16.2%) but no difference for deep reflux (20.7% vs. 17.5%) or outward flow in calf perforators (56.8% vs. 53.1%). The source for recurrence in the long saphenous territory was from a single large connection in the groin in 46.3%, multiple smaller proximal connections in a further 46.3%, or thigh perforators in 7.4%. The destination was to an intact long saphenous vein in 33.7%, major tributaries in 28.7% or to other varices in 37.6%. Limbs known to have been treated by long saphenous ligation alone were compared with those known to be treated by long saphenous ligation and stripping; the source was more likely to be from a single large vein in the groin (60.3% vs. 39.9%) and the destination was more likely to be an intact long saphenous vein or major tributary (75.0% vs. 55.2%). Conclusions: Duplex ultrasound scanning detected the source of recurrent varicose veins in over 90% of patients and demonstrated whether there were single large or multiple smaller connections in the veins affected, and this helps to select the most appropriate treatment. Recurrence after stripping the long saphenous vein was more likely to be due to multiple small connections passing to scattered varices and this may allow more simple treatment by injection sclerotherapy rather than repeat surgery.


1996 ◽  
Vol 11 (3) ◽  
pp. 98-101 ◽  
Author(s):  
P. Zamboni ◽  
C.V. Feo ◽  
M. G. Marcellino ◽  
G. Vasquez ◽  
C. Mari

Objective: Evaluation of the feasibility and utility of haemodynamic correction of primary varicose veins (French acronym: CHIVA). Design: Prospective, single patient group study. Setting: Department of Surgery, University of Ferrara, Italy (teaching hospital). Patients: Fifty-five patients with primary varicose veins and a normal deep venous system (ultrasonographic criteria) were studied. Interventions: Fifty-five haemodynamic corrections by the CHIVA method described by Franceschi were undertaken. Seven patients were treated for short saphenous vein varices (group A) while 48 patients were treated for long saphenous vein varices (group B). Main outcome measures: Clinical: presence of varices and reduction in symptoms. Duplex and continuous-wave Doppler detection of re-entry through the perforators and identification of recurrences or new sites of reflux. Postoperative ambulatory venous pressure and refilling time measurements. Patients were studied for 3 years following surgery. Results: In group A, 57% short saphenous vein occlusions with no re-entry through the gastrocnemius and soleal veins were recorded. In group B the long saphenous vein thrombosis rate was 10%. In this group 15% of the patients showed persistence of reflux instead of re-entry at the perforators. Early recurrences were also observed. Overall CHIVA gave excellent results in 78% of the patients. Statistically significant ambulatory venous pressure and refilling time changes were recorded ( p<0.001). Conclusions: CHIVA treatment is inadvisable for short saphenous vein varices. Long saphenous vein postoperative thrombosis is related to development of recurrences


2002 ◽  
Vol 16 (3) ◽  
pp. 98-100 ◽  
Author(s):  
N. Jessen ◽  
N. Bækgaard

Objective: To evaluate the outcome of re-operation in the groin for recurrent varicose veins. Design: Retropective follow-up study Setting: Department of Vascular Surgery, Gentofte University Hospital, Copenhagen, Denmark. Methods and materials: Thirty-two patients with 43 operated legs. Operations were performed between January 1996 and the end of April 1997 and solely as a groin dissection; no stripping was done. Follow-up consisted of a clinical examination and duplex scanning with an ATL HDI 5000 scanner. Results: Sixteen cured legs, 17 with reflux beginning at mid-thigh, mainly a Hunter's perforating vein, and 10 with remaining reflux at the sapheno-femoral junction. Conclusion: Recurrence rate in the groin is acceptable. Stripping of the long saphenous vein is mandatory to bring down the recurrence rate from mid-thigh perforating veins. This is now standard procedure in our department.


Sign in / Sign up

Export Citation Format

Share Document