Validation of 68Ga-HBED-CC PSMA-PET/CT and multiparametric MRI for gross tumor volume delineation in patients with primary prostate cancer based on comparison with histology reference

2016 ◽  
Vol 69 ◽  
pp. S60
Author(s):  
C. Zamboglou ◽  
V. Drendel ◽  
C.A. Jilg ◽  
H.C. Rischke ◽  
T.I. Beck ◽  
...  
2020 ◽  
Vol 10 ◽  
Author(s):  
Simon K. B. Spohn ◽  
Maria Kramer ◽  
Selina Kiefer ◽  
Peter Bronsert ◽  
August Sigle ◽  
...  

PurposeAccurate contouring of intraprostatic gross tumor volume (GTV) is pivotal for successful delivery of focal therapies and for biopsy guidance in patients with primary prostate cancer (PCa). Contouring of GTVs, using 18-Fluor labeled tracer prostate specific membrane antigen positron emission tomography ([18F]PSMA-1007/PET) has not been examined yet.Patients and MethodsTen Patients with primary PCa who underwent [18F]PSMA-1007 PET followed by radical prostatectomy were prospectively enrolled. Coregistered histopathological gross tumor volume (GTV-Histo) was used as standard of reference. PSMA-PET images were contoured on two ways: (1) manual contouring with PET scaling SUVmin-max: 0–10 was performed by three teams with different levels of experience. Team 1 repeated contouring at a different time point, resulting in n = 4 manual contours. (2) Semi-automatic contouring approaches using SUVmax thresholds of 20–50% were performed. Interobserver agreement was assessed for manual contouring by calculating the Dice Similarity Coefficient (DSC) and for all approaches sensitivity, specificity were calculated by dividing the prostate in each CT slice into four equal quadrants under consideration of histopathology as standard of reference.ResultsManual contouring yielded an excellent interobserver agreement with a median DSC of 0.90 (range 0.87–0.94). Volumes derived from scaling SUVmin-max 0–10 showed no statistically significant difference from GTV-Histo and high sensitivities (median 87%, range 84–90%) and specificities (median 96%, range 96–100%). GTVs using semi-automatic segmentation applying a threshold of 20–40% of SUVmax showed no significant difference in absolute volumes to GTV-Histo, GTV-SUV50% was significantly smaller. Best performing semi-automatic contour (GTV-SUV20%) achieved high sensitivity (median 93%) and specificity (median 96%). There was no statistically significant difference to SUVmin-max 0–10.ConclusionManual contouring with PET scaling SUVmin-max 0–10 and semi-automatic contouring applying a threshold of 20% of SUVmax achieved high sensitivities and very high specificities and are recommended for [18F]PSMA-1007 PET based focal therapy approaches. Providing high specificities, semi-automatic approaches applying thresholds of 30–40% of SUVmax are recommend for biopsy guidance.


2021 ◽  
Vol 11 (3) ◽  
pp. 202-211
Author(s):  
Cédric Draulans ◽  
Floris Pos ◽  
Robert J. Smeenk ◽  
Linda Kerkmeijer ◽  
Wouter V. Vogel ◽  
...  

Theranostics ◽  
2017 ◽  
Vol 7 (1) ◽  
pp. 228-237 ◽  
Author(s):  
Constantinos Zamboglou ◽  
Vanessa Drendel ◽  
Cordula A. Jilg ◽  
Hans C. Rischke ◽  
Teresa I. Beck ◽  
...  

2021 ◽  
Vol 11 ◽  
Author(s):  
Lena M. Mittlmeier ◽  
Matthias Brendel ◽  
Leonie Beyer ◽  
Nathalie L. Albert ◽  
Andrei Todica ◽  
...  

BackgroundDelineation of PSMA-positive tumor volume on PET using PSMA-ligands is of highest clinical interest as changes of PSMA-PET/CT-derived whole tumor volume (WTV) have shown to correlate with treatment response in metastatic prostate cancer patients. So far, WTV estimation was performed on PET using 68Ga-labeled ligands; nonetheless, 18F-labeled PET ligands are gaining increasing importance due to advantages over 68Ga-labeled compounds. However, standardized tumor delineation methods for 18F-labeled PET ligands have not been established so far. As correlation of PET-based information and morphological extent in osseous and visceral metastases is hampered by morphological delineation, low contrast in liver tissue and movement artefacts, we correlated CT-based volume of lymph node metastases (LNM) and different PET-based delineation approaches for thresholding on 18F-PSMA-1007 PET.MethodsFifty patients with metastatic prostate cancer, 18F-PSMA-1007 PET/CT and non-bulky LNM (short-axis diameter ≥10mm) were included. Fifty LNM were volumetrically assessed on contrast-enhanced CT (volumetric reference standard). Different approaches for tumor volume delineation were applied and correlated with the reference standard: I) fixed SUV threshold, II) isocontour thresholding relative to SUVmax (SUV%), and thresholds relative to III) liver (SUVliver), IV) parotis (SUVparotis) and V) spleen (SUVspleen).ResultsA fixed SUV of 4.0 (r=0.807, r2 = 0.651, p<0.001) showed the best overall association with the volumetric reference. 55% SUVmax (r=0.627, r2 = 0.393, p<0.001) showed highest association using an isocontour-based threshold. Best background-based approaches were 60% SUVliver (r=0.715, r2 = 0.511, p<0.001), 80% SUVparotis (r=0.762, r2 = 0.581, p<0.001) and 60% SUVspleen (r=0.645, r2 = 0.416, p<0.001). Background tissues SUVliver, SUVparotis & SUVspleen did not correlate (p>0.05 each). Recently reported cut-offs for intraprostatic tumor delineation (isocontour 44% SUVmax, 42% SUVmax and 20% SUVmax) revealed inferior association for LNM delineation.ConclusionsA threshold of SUV 4.0 for tumor delineation showed highest association with volumetric reference standard irrespective of potential changes in PSMA-avidity of background tissues (e. g. parotis). This approach is easily applicable in clinical routine without specific software requirements. Further studies applying this approach for total tumor volume delineation are initiated.


2020 ◽  
Vol 152 ◽  
pp. S104
Author(s):  
S. Spohn ◽  
C. Jaegle ◽  
A.S. Bettermann ◽  
S. Kiefer ◽  
C.A. Jilg ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document