Development and validation of a fast and sensitive chromatographic assay for all-trans-retinol and tocopherols in human serum and plasma using liquid–liquid extraction

2002 ◽  
Vol 780 (2) ◽  
pp. 261-267 ◽  
Author(s):  
G Taibi ◽  
C.M.A Nicotra
Author(s):  
Rebecca A Mastrovito ◽  
Donna M Papsun ◽  
Barry K Logan

Abstract Novel illicit benzodiazepines are among the most active areas of new illicit drug manufacture and use. We describe a method for the detection and quantification of etizolam and its metabolite α-hydroxyetizolam, flubromazolam, clonazolam, diclazepam, delorazepam, bromazepam, flubromazepam, phenazepam, flualprazolam, flunitrazolam, and nitrazolam in human whole blood. After addition of internal standards, samples are buffered and extracted using a liquid–liquid extraction. Analysis is performed using positive-ion electrospray tandem mass spectrometry for detection and quantitation. Calibration ranges were established based on the method performance and differed from compound to compound. Replicates at the lowest calibration point for each compound performed within 5% of CV (Coefficient of Variation). The correlation coefficient was >0.990 for all compounds. Relative standard deviation for all compounds was ≤10% of CV and accuracy was  ±10% for both within- and between-run experiments. The maximum average intra- and inter-run imprecision were 5.7%. The maximum average intra- and inter-run imprecision was −8.7%. As part of evaluating the scope for relevancy, samples testing positive in immunoassay but confirmed to be negative in traditional benzodiazepine confirmation method were re-analyzed using this method. The presence of at least one novel benzodiazepine was identified in 70% of these samples. The appearance of these novel “designer” benzodiazepines demonstrates the challenge for toxicology testing and the need for continually updated confirmation methods.


2011 ◽  
Vol 205 ◽  
pp. S209-S210
Author(s):  
R. Wietecha-Posłuszny ◽  
M. Woźniakiewicz ◽  
A. Garbacik ◽  
P. Kościelniak

Author(s):  
Taís B Rodrigues ◽  
Damila R Morais ◽  
Victor A P Gianvecchio ◽  
Elvis M Aquino ◽  
Ricardo L Cunha ◽  
...  

Abstract The development of new sample preparation alternatives in analytical toxicology leading to quick, effective, automated and environmentally friendly procedures is growing in importance. One of these alternatives is the QuEChERS, originally developed for the analysis of pesticide residues, producing cleaner extracts than liquid–liquid extraction, and easier separation of aqueous and organic phases. However, there are few published studies on the miniaturization of this technique for forensic toxicology, especially in postmortem analysis. We developed and validated a modified micro-QuEChERS and LC–MS-MS assay to quantify 16 antidepressants, 7 antipsychotics and 3 metabolites and semi-quantify norfluoxetine and norsertraline in postmortem blood. The calibration curve was linear from 1 to 500 ng/mL, achieved an r > 0.99, with all standards quantifying within ±15% of target except ±20% at the limit of quantification of 1 ng/mL for 26 substances. The F test was applied to evaluate if the variance between replicates remained constant for all calibrators. Six weighting factors were analyzed (1/x, 1/x2, 1/x0,5, 1/y, 1/y2 and 1/y0,5), with the weighting factor with the lowest sum of residual regression errors (1/x2) selected. No endogenous or exogenous interferences were observed. Method imprecision and bias were <19.0% and 19.7%, respectively. Advantages of this method include a low sample volume of 100 µL, simple but effective sample preparation and a rapid 8.5-min run time. The validated analytical method was successfully applied to the analysis of 100 authentic postmortem samples.


Química Nova ◽  
2012 ◽  
Vol 35 (2) ◽  
pp. 411-415 ◽  
Author(s):  
Sigrid Mennickent ◽  
Jonathan Contreras ◽  
Berta Schulz ◽  
Marta de Diego ◽  
Mario Vega