Common patterns of response to the head-up tilt test in children and adolescents

2006 ◽  
Vol 16 (6) ◽  
pp. 537-539 ◽  
Author(s):  
Arnulf Boysen ◽  
Martin A.G. Lewin ◽  
Frank Uhlemann

Testing using the head-up tilt table is performed regularly as a diagnostic tool in the evaluation of syncope. Recommendations for protocols, and interpretation of the results, however, are mainly based on experience in adults. We evaluated the results of tilt table testing in 100 consecutive children and adolescents aged from 6 to 18 years and referred for investigation of syncope. Over half the patients, 55%, proved impossible to classify using the criterions established by the European Society of Cardiology. Based on our data, we propose a modified classification for responses to tilt table testing in the young.

2021 ◽  
Vol 14 (10) ◽  
pp. e245083
Author(s):  
Muhammad Taha Khan ◽  
Aamir Hameed ◽  
Yawer Saeed

Broad complex tachycardia (BCT) during head up tilt test (HUTT) is infrequent. Electrophysiology Study (EPS) plays an important part in further differentiation of BCT. We present a case of BCT during HUTT in a patient presenting with presyncope which later on EPS with 3D mapping was diagnosed as ventricular tachycardia. This case highlights the unusual occurrence of BCT during HUTT, the differential diagnosis of BCT and the utility of EPS to reliably identify the type and origin of BCT.


2001 ◽  
Vol 80 (1) ◽  
pp. 69-76 ◽  
Author(s):  
R.Y.T Sung ◽  
C.W Yu ◽  
Eddie Ng ◽  
Z.D Du ◽  
Brian Tomlinson ◽  
...  

2021 ◽  
Vol 9 ◽  
Author(s):  
Hong Cai ◽  
Shuo Wang ◽  
Runmei Zou ◽  
Ping Liu ◽  
Fang Li ◽  
...  

Objectives: We aimed to compare the hemodynamic responses to the active sitting test with the passive head-up tilt test (HUTT) in children and adolescents with postural tachycardia syndrome (POTS). We hypothesized that sitting tachycardia was also present in POTS patients during sitting.Materials and methods: We tested 30 POTS patients and 31 control subjects (mean age = 12 years, range = 9–16 years) who underwent both active sitting test and HUTT successively. We measured the heart rate (HR) and blood pressure (BP) during each test.Results: For both POTS patients and control subjects, the HUTT produced significantly larger HR and BP increases from 3 to 10 min of postural change than did the sitting test. Moreover, POTS patients with excessive orthostatic tachycardia during the HUTT also had significantly larger increases in HR at all test intervals during the sitting test than did the control subjects. A maximum increase in HR ≥ 22 bpm within 10 min of the sitting test was likely suggested to predict orthostatic tachycardia, yielding a sensitivity and specificity of 83.3 and 83.9%, respectively. Only six of 30 POTS patients (20%) reached the 40-bpm criterion during the sitting test, and no one complained of sitting intolerance symptoms.Conclusions: We have shown that POTS patients also have sitting tachycardia when changing from a supine position to a sitting position. We believe that the active sitting test is a reasonable alternative maneuver in assessing POTS in population groups that cannot tolerate the standing test or HUTT.


2009 ◽  
Vol 52 (7) ◽  
pp. 798 ◽  
Author(s):  
Ka-Young Yu ◽  
Ji-Hye Choi ◽  
Chun Ja Yoo ◽  
Kyoung Suk Rhee ◽  
Chan Uhng Joo

PEDIATRICS ◽  
1998 ◽  
Vol 101 (2) ◽  
pp. e6-e6 ◽  
Author(s):  
J. E. Naschitz ◽  
D. Hardoff ◽  
I. Bystritzki ◽  
D. Yeshurun ◽  
L. Gaitini ◽  
...  

2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
M Sotiriadou ◽  
A Antoniadis ◽  
S Vergopoulos ◽  
C Lazaridis ◽  
P Konstantinidis ◽  
...  

Abstract Background/Introduction Head-up tilt table test (HUTT) and Adenosine test (ADT) can be useful in the diagnostic evaluation of syncope. Adenosine plasma (ADP) and Adenosine receptor (ADR) levels may differentiate the outcomes of HUTT and ADT but their precise role in the risk stratification of patients with syncope remains elusive. Purpose We sought to assess the ADP and ADR levels in patients without structural heart disease who underwent HUTT and ADT tests as part of the diagnostic workup of syncope. We specifically investigated differences in the outcomes of the HUTT and ADT tests as well as to the ADP levels during HUTT according to the baseline ADP levels. Methods HUTT and ADT were performed as per the standard protocols. ADT was considered positive in the event of asystole >6 seconds or heart block for >10 seconds after intravenous Adenosine 0.15 mg/kg administration in the supine position. ADP levels (ppm/Um/L) were assessed at three timepoints during the HUTT: at baseline (supine), immediately after bed tilt and, in cases of a positive HUTT, at the time of syncope. Patients were categorized in terciles of low, intermediate and high baseline ADP levels. We also assessed the A2A ADR levels of monocytes. Results We prospectively analyzed 106 patients (62 women, age 46.87±20.63 years). ADT was positive in 14.2% of patients and HUTT in 47.2% of patients. Females were more likely to have low ADP levels (odds ratio [OR] 2.70, 95% Confidence Interval [CI] 1.04 to 6.94, p<0.05). Patients with low baseline ADP levels showed a trend for positive ADT (OR 3.15, 95% CI 1.05 to 10.85, p=0.07), while patients with high baseline ADP levels showed a trend for negative HUTT (OR 2.35, 95% CI 0.94 to 5.90, p=0.075). Within patients with positive HUTT, those with low baseline ADP levels, showed an increase in ADP in the tilt phase (0.063 vs 0.027 ppm/Um/L, p<0.05) but not at the time of syncope (0.045 ppm/Um/L) while those with intermediate baseline ADP levels showed an increase in ADP in the tilt phase (0.16 vs 0.095 ppm/Um/L, p<0.05) which persisted during syncope (0.18 ppm/Um/L, p<0.05). Patients with high baseline ADP levels did not exhibit differences in ADP during positive HUTT. Higher baseline ADP levels were associated with smaller increases in the tilt phase (Pearson's r −0.621, p<0.001). ADR levels in patients with positive HUTT correlated positively with baseline ADP levels (Pearson's r 0.878, p<0.001). Conclusion(s) Baseline ADP levels may be related to the outcome of ADT and HUTT. ADP increases during HUTT except for patients with high baseline ADP. ADP and ADR levels warrant further investigation as they may characterize a subset of patients with specific responses to HUTT and may be implicated in the pathophysiology of reflex syncope. Funding Acknowledgement Type of funding source: None


Sign in / Sign up

Export Citation Format

Share Document