scholarly journals EPMA EDS/WDS Comparative Analysis on Bulk and Lamella Aluminide Coatings on Stainless Steel

2021 ◽  
Vol 27 (S1) ◽  
pp. 3370-3371
Author(s):  
Joshua Silverstein ◽  
Bethany Matthews
2020 ◽  
Vol 30 ◽  
pp. 361-364
Author(s):  
Andrey Lapechenkov ◽  
Aleksandr Fedorov ◽  
Lyudmila Galata ◽  
Aleksey Piskarev

2012 ◽  
Vol 602-604 ◽  
pp. 1181-1185 ◽  
Author(s):  
Javad Malekani ◽  
Beat Schmutz ◽  
Prasad Gudimetla ◽  
Yuan Tong Gu ◽  
Michael Schuetz ◽  
...  

Distal tibial fractures are now commonly treated via intermedullary plate fixation due to higher rates of union and lower rates of postoperative complications. However, patient specific bone morphology demands manual deformation of the plate to ensure appropriate fit along the bone contours, and depending on the material of the plate, different outcomes have been reported along with postoperative complications. A comparative analysis of Stainless Steel 316L and Ti-6Al-4V alloys was carried to estimate the safe bending limit for appropriate fits. The results from the ANSYS FEA simulations were validated with experiments based on ASTM F382-99. It is found that SS316L is better suited for large deformations (up to 16˚ in proximal tip and 7.5˚ in distal end) and Ti for smaller deformation contours (up to 3˚ in proximal tip and 1.8˚ in distal end). The results of this study have profound implications for the choice of plates based on preliminary radiographical fracture examinations to ensure better fixation and higher rates of union of distal tibial fractures.


2020 ◽  
Vol 1 (2) ◽  
pp. 12-17
Author(s):  
Chao Zhang ◽  
Xiang Yin ◽  
Chun Qing

The objective of the study was to conduct the comparative analysis of steel types corrosion resistance. Three selected steel types were used in the study. The selected types were structural steel, stainless steel, and MMFX steel. The methodology we adopted is that we evaluated the steel parts resistance towards corrosion by doing in-salt spray experiment and the immersion of aqueous solution of sodium chloride. For salt spray test, we used guidelines by ASTM B117. This practice provides a controlled corrosion environment which is used for exposing specimen to salt spray chamber. For immersion test, test specimens are analyzed at regular time interval as the first rust is appeared. For carbon steel, we used three specimen and mostly initial rust appeared in initial 13 to 15 hours. For stainless steel, inter granular corrosion were analyzed. The results show that the first cycle started after about 46 hours; the second cycle started about 1% and the third cycle started with the rage of about 2 to 30%. For MMFX 2 steel, the results show that for MMFX carbon steel, the chloride threshold ratio is about 6 times higher than black bars and more than double of other types. The conclusion of the study is that in big structures like bridges, the MMFX steel should be used.


Sign in / Sign up

Export Citation Format

Share Document