Standard Validation Protocol for Selected Ion Flow Tube Mass Spectrometry Methods Applied to Direct Headspace Analysis of Aqueous Volatile Organic Compounds

Author(s):  
Mark J. Perkins ◽  
Vaughan S. Langford
2007 ◽  
Vol 77 (1-2) ◽  
pp. 20-23 ◽  
Author(s):  
Andrew R. Moot ◽  
Katherine M. Ledingham ◽  
Paul F. Wilson ◽  
Senti T. Senthilmohan ◽  
David R. Lewis ◽  
...  

2021 ◽  
Author(s):  
Ilaria Belluomo ◽  
Piers R. Boshier ◽  
Antonis Myridakis ◽  
Bhamini Vadhwana ◽  
Sheraz R. Markar ◽  
...  

2015 ◽  
Vol 7 (10) ◽  
pp. 4104-4110 ◽  
Author(s):  
David Smith ◽  
Roger Bloor ◽  
Claire George ◽  
Andriy Pysanenko ◽  
Patrik Španěl

Selected ion flow tube mass spectrometry (SIFT-MS) has been used to analyse the volatile compounds released when “street” cannabis is heated in the commercial device known as the “Volcano”.


Medicina ◽  
2019 ◽  
Vol 55 (6) ◽  
pp. 306 ◽  
Author(s):  
Dhinashini Chandran ◽  
Eng H. Ooi ◽  
David I Watson ◽  
Feruza Kholmurodova ◽  
Simone Jaenisch ◽  
...  

Background: Head and neck squamous cell carcinoma (HNSCC) is the sixth most common form of cancer worldwide, with approximately 630,000 new cases diagnosed each year. The development of low-cost and non-invasive tools for the detection of HNSCC using volatile organic compounds (VOCs) in the breath could potentially improve patient care. The aim of this study was to investigate the feasibility of selected ion flow tube mass spectrometry (SIFT-MS) technology to identify breath VOCs for the detection of HNSCC. Materials and Methods: Breath samples were obtained from HNSCC patients (N = 23) and healthy volunteers (N = 21). Exhaled alveolar breath samples were collected into FlexFoil® PLUS (SKC Limited, Dorset, UK) sampling bags from newly diagnosed, histologically confirmed, untreated patients with HNSCC and from non-cancer participants. Breath samples were analyzed by Selected Ion Flow Tube-Mass Spectrometry (SIFT-MS) (Syft Technologies, Christchurch, New Zealand) using Selective Ion Mode (SIM) scans that probed for 91 specific VOCs that had been previously reported as breath biomarkers of HNSCC and other malignancies. Results: Of the 91 compounds analyzed, the median concentration of hydrogen cyanide (HCN) was significantly higher in the HNSCC group (2.5 ppb, 1.6–4.4) compared to the non-cancer group (1.1 ppb, 0.9–1.3; Benjamini–Hochberg adjusted p < 0.05). A receiver operating curve (ROC) analysis showed an area under the curve (AUC) of 0.801 (95% CI, 0.65952–0.94296), suggesting moderate accuracy of HCN in distinguishing HNSCC from non-cancer individuals. There were no statistically significant differences in the concentrations of the other compounds of interest that were analyzed. Conclusions: This pilot study demonstrated the feasibility of SIFT-MS technology to identify VOCs for the detection of HNSCC.


Sign in / Sign up

Export Citation Format

Share Document