Surface Plasmon Resonance-Based Membrane Protein-Targeted Active Ingredients Recognition Strategy: Construction and Implementation in Ligand Screening from Herbal Medicines

2020 ◽  
Vol 92 (5) ◽  
pp. 3972-3980 ◽  
Author(s):  
Langdong Chen ◽  
Diya Lv ◽  
Shaozhan Wang ◽  
Dongyao Wang ◽  
Xiaofei Chen ◽  
...  
Membranes ◽  
2020 ◽  
Vol 10 (9) ◽  
pp. 247
Author(s):  
Wenwen Jing ◽  
Ashley Hunt ◽  
Nongjian Tao ◽  
Fenni Zhang ◽  
Shaopeng Wang

Most drugs work by binding to receptors on the cell surface. Quantification of binding kinetics between drug and membrane protein is an essential step in drug discovery. Current methods for measuring binding kinetics involve extracting the membrane protein and labeling, and both have issues. Surface plasmon resonance (SPR) imaging has been demonstrated for quantification of protein binding to cells with single-cell resolution, but it only senses the bottom of the cell and the signal diminishes with the molecule size. We have discovered that ligand binding to the cell surface is accompanied by a small cell membrane deformation, which can be used to measure the binding kinetics by tracking the cell edge deformation. Here, we report the first integration of SPR imaging and cell edge tracking methods in a single device, and we use lectin interaction as a model system to demonstrate the capability of the device. The integration enables the simultaneous collection of complementary information provided by both methods. Edge tracking provides the advantage of small molecule binding detection capability, while the SPR signal scales with the ligand mass and can quantify membrane protein density. The kinetic constants from the two methods were cross-validated and found to be in agreement at the single-cell level. The variation of observed rate constant between the two methods is about 0.009 s−1, which is about the same level as the cell-to-cell variations. This result confirms that both methods can be used to measure whole-cell binding kinetics, and the integration improves the reliability and capability of the measurement.


2017 ◽  
Vol 12 (9) ◽  
pp. 1700154 ◽  
Author(s):  
Karin P. M. Geuijen ◽  
Daniëlle E. J. W. van Wijk-Basten ◽  
David F. Egging ◽  
Richard B. M. Schasfoort ◽  
Michel H. Eppink

2009 ◽  
Vol 4 (11) ◽  
pp. 1542-1558 ◽  
Author(s):  
Jennifer A. Maynard ◽  
Nathan C. Lindquist ◽  
Jamie N. Sutherland ◽  
Antoine Lesuffleur ◽  
Arthur E. Warrington ◽  
...  

2020 ◽  
pp. 44-49
Author(s):  
I. N. Pavlov

Two optical methods, namely surface plasmon resonance imaging and frustrated total internal reflection, are described in the paper in terms of comparing their sensitivity to change of refractive index of a thin boundary layer of an investigated medium. It is shown that, despite the fact that the theoretically calculated sensitivity is higher for the frustrated total internal reflection method, and the fact that usually in practice the surface plasmon resonance method, on the contrary, is considered more sensitive, under the same experimental conditions both methods show a similar result.


Sign in / Sign up

Export Citation Format

Share Document