surface plasmon resonance biosensor
Recently Published Documents


TOTAL DOCUMENTS

570
(FIVE YEARS 114)

H-INDEX

56
(FIVE YEARS 10)

Biosensors ◽  
2022 ◽  
Vol 12 (1) ◽  
pp. 27
Author(s):  
Zhitao Lin ◽  
Yiqing Shu ◽  
Weicheng Chen ◽  
Yang Zhao ◽  
Jianqing Li

PtSe2 as a novel TMDCs material is used to modify the traditional SPR biosensors to improve the performance. On this basis, this research proposes a metal-Si-metal waveguide structure to further improve the performance of the biosensor. In this study, we not only studied the effects of waveguide structures containing different metals on the performance of biosensor, but also discussed the performance change of the biosensor with the change of PtSe2 thickness. After the final optimization, a BK7-Au-Si-Au-PtSe2 (2 nm) biosensor structure achieved the highest sensitivity of 193.8°/RIU. This work provides a new development idea for the study of SPR biosensors with waveguide structures in the future.


2021 ◽  
Vol 9 (2) ◽  
pp. 30-32
Author(s):  
Noor Azlina Masdor

Biochemical diagnostic procedures, such as protein binding, rely on biomolecular interactions as its diagnostic modality, and as a consequence, their calibration curves are more complex. In addition, sigmoidal curves are often seen in these tests. In the event of asymmetry, a logistic (5PL) curve, or a logistic (4PL) curve, may be the best way to represent a distinctive sigmoidal relationship. It is possible that the linearization of an otherwise nonlinear connection by log transformation may result in a disruption of the error structure of the curve, and that this will have the opposite effect of decreasing or even eliminating error in the relationship. Previously, a surface plasmon resonance biosensor for the detection of squamous cell carcinoma antigen (SCCa) using nanoparticle technology was developed. However, based on the calibration curve, it conforms to the majority on sigmoidal shape curve for antibody-type sensing system. The resultant curve showed a sigmoidal calibration curve but was not modelled according to any of the sigmoidal models available. The LOD value obtained through the 4PL modelling exercise based on the classical method was 0.255 pM (95% confidence interval of 0.167 to 0.379) while the pooled standard deviation (PSD) method yielded an LOD value of 0.035 pM (95% confidence interval of 0.011 to 0.067), which indicates that the PSD method was superior.


Biosensors ◽  
2021 ◽  
Vol 11 (10) ◽  
pp. 383
Author(s):  
Thai Thao Ly ◽  
Yinlan Ruan ◽  
Bobo Du ◽  
Peipei Jia ◽  
Hu Zhang

An extraordinary optical transmission fibre-optic surface plasmon resonance biosensing platform was engineered to improve its portability and sensitivity, and was applied to monitor the concentrations of monoclonal antibodies (Mabs). By refining the fabricating procedure and changing the material of the flow cell and the components of the optical fibre, the biosensor is portable and robust to external interference. After the implementation of an effective template cleaning procedure and precise control during the fabrication process, a consistent sensitivity of 509 ± 5 nm per refractive index unit (nm/RIU) was achieved. The biosensor can detect the Mab with a limit of detection (LOD) of 0.44 µg/mL. The results show that the biosensor is a potential tool for the rapid quantification of Mab titers. The biosensor can be regenerated at least 10 times with 10 mM glycine (pH = 2.5), and consistent signal changes were obtained after regeneration. Moreover, the employment of a spacer arm SM(PEG)2, used for immobilising protein A onto the gold film, was demonstrated to be unable to improve the detecting sensitivity; thus, a simple procedure without the spacer arm could be used to prepare the protein A-based biosensor. Our results demonstrate that the fibre-optic surface plasmon resonance biosensor is competent for the real-time and on-line monitoring of antibody titers in the future as a process analytical technologies (PATs) tool for bioprocess developments and the manufacture of therapeutic antibodies.