Design of Electrochemically Reduced Graphene Oxide/Titanium Disulfide Nanocomposite Sensor for Selective Determination of Ascorbic Acid

Author(s):  
Priyanka Pal ◽  
Sangya Bhattacharjee ◽  
Merina Paul Das ◽  
Yoon-Bo Shim ◽  
Bernaurdshaw Neppolian ◽  
...  
2018 ◽  
Vol 2018 ◽  
pp. 1-15 ◽  
Author(s):  
Nguyen Hai Phong ◽  
Tran Thanh Tam Toan ◽  
Mai Xuan Tinh ◽  
Tran Ngoc Tuyen ◽  
Tran Xuan Mau ◽  
...  

In the present paper, graphene oxide was directly electrodeposited by means of cyclic voltammetric techniques on the glassy-carbon electrode (GCE) to obtain a reduced graphene-oxide-modified electrode (ErGO/GCE). Cyclic voltammetry (CV) and differential pulse anodic stripping voltammetry (DP-ASV) had been utilized to study the electrochemical behavior of ErGO/GCE toward ascorbic acid (AA), paracetamol (PA), and caffeine (CA). Differential pulse voltammetry results show that AA, PA, and CA could be detected selectively and sensitively on ErGO/GCE with peak-to-peak separation of 312 mV and 756 mV for AA–PA and PA–CA, respectively. The factors affecting the voltammetric signals such as pH, scan rate, and interferents were addressed. The results reveal that the ErGO/GCE-modified electrode exhibits excellent electrochemical activity in the oxidation of PA, CA, and AA. The detection limits are 0.36 μM, 0.25 μM, and 0.23 μM for AA, PA and CA, respectively, suggesting that the ErGO/GCE can be utilized with high sensitivity and selectivity for the simultaneous determination of these compounds. Finally, the proposed method was successfully used to determine AA, PA, and CA in pharmaceutical preparations.


2014 ◽  
Vol 2014 ◽  
pp. 1-10 ◽  
Author(s):  
Gen Liu ◽  
Wei Ma ◽  
Yan Luo ◽  
Deng-ming Sun ◽  
Shuang Shao

Poly(methylene blue) and electrochemically reduced graphene oxide composite film modified electrode (PMB-ERGO/GCE) was successfully fabricated by electropolymerization and was used for simultaneous determination of uric acid (UA) and xanthine (Xa). Based on the excellent electrocatalytic activity of PMB-ERGO/GCE, the electrochemical behaviors of UA and Xa were studied by cyclic voltammetry (CV) and square wave voltammetry (SWV). Two anodic sensitive peaks at 0.630 V (versus Ag/AgCl) for UA and 1.006 V (versus Ag/AgCl) for Xa were given by CV in pH 3.0 phosphate buffer. The calibration curves for UA and Xa were obtained in the range of 8.00 × 10−8~4.00 × 10−4 M and 1.00 × 10−7~4.00 × 10−4 M, respectively, by SWV. The detection limits for UA and Xa were3.00×10-8 M and5.00×10-8 M, respectively. Finally, the proposed method was applied to simultaneously determine UA and Xa in human urine with good selectivity and high sensitivity.


Sign in / Sign up

Export Citation Format

Share Document