scholarly journals Visualizing nanometric structures with sub-millimeter waves

2021 ◽  
Vol 12 (1) ◽  
Author(s):  
Alonso Ingar Romero ◽  
Amlan kusum Mukherjee ◽  
Anuar Fernandez Olvera ◽  
Mario Méndez Aller ◽  
Sascha Preu

AbstractThe resolution along the propagation direction of far field imagers can be much smaller than the wavelength by exploiting coherent interference phenomena. We demonstrate a height profile precision as low as 31 nm using wavelengths between 0.375 mm and 0.5 mm (corresponding to 0.6 THz–0.8 THz) by evaluating the Fabry-Pérot oscillations within surface-structured samples. We prove the extreme precision by visualizing structures with a height of only 49 nm, corresponding to 1:7500 to 1:10000 vacuum wavelengths, a height difference usually only accessible to near field measurement techniques at this wavelength range. At the same time, the approach can determine thicknesses in the centimeter range, surpassing the dynamic range of any near field measurement system by orders of magnitude. The measurement technique combined with a Hilbert-transform approach yields the (optical) thickness extracted from the relative phase without any extraordinary wavelength stabilization.

2021 ◽  
Author(s):  
Alonso Ingar Romero ◽  
Amlan kusum Mukherjee ◽  
Anuar Fernandez Olvera ◽  
Mario Mendez Aller ◽  
Sascha Preu

Abstract The resolution along the propagation direction of far field imagers can be much smaller than the wavelength by exploiting coherent interference phenomena. We demonstrate a height profile precision as low as 31 nm using wavelengths between 0.375 mm and 0.5 mm (corresponding to 0.6 THz-0.8 THz) by evaluating the Fabry-Pérot oscillations within surface-structured samples. We prove the extreme precision by visualizing structures with a height of only 49 nm, corresponding to 1:7500 to 1:10000 vacuum wavelengths, a height difference usually only accessible to near field measurement techniques at this wavelength range. This precision surpasses the state-of-the-art by 1-2 orders of magnitude. At the same time, the approach can determine thicknesses in the centimeter range, surpassing the dynamic range of any near field measurement system by orders of magnitude. The measurement technique combined with a Hilbert-transform approach yields the (optical) thickness extracted from the relative phase without any extraordinary wavelength stabilization.


1969 ◽  
Vol 59 (3) ◽  
pp. 1213-1225
Author(s):  
Paul Reasenberg

abstract An accelerometer system designed for the seismic near-field measurement is described. The wide dynamic range of the system, and the anticipated acceleration spectral density require that the accelerometers be highly linear. A method for determining the linearity is described.


2020 ◽  
pp. 1-1
Author(s):  
Weiheng Shao ◽  
Xinxin Tian ◽  
Rongquan Chen ◽  
Xiao He ◽  
Wenxiao Fang ◽  
...  

Sign in / Sign up