field measurement
Recently Published Documents


TOTAL DOCUMENTS

3150
(FIVE YEARS 519)

H-INDEX

61
(FIVE YEARS 8)

2022 ◽  
Vol 121 ◽  
pp. 104341
Author(s):  
Zhaoxiang Chu ◽  
Guoqing Zhou ◽  
Zhonghao Rao ◽  
Yijiang Wang ◽  
Xiaodong Zhao

Materials ◽  
2022 ◽  
Vol 15 (2) ◽  
pp. 493
Author(s):  
Jiaxing Hu ◽  
Zhengnong Li ◽  
Zhefei Zhao

The field measurement of wind-induced response is of great significance to the wind resistance design of high-rise buildings, in particular torsional responses measured from high-rise buildings under typhoons. The measured high-rise building, with a height of 108 m, has 32 stories and is supported by giant trusses with four massive columns. Acceleration responses along translational and torsional directions were monitored synchronously and continuously during the passage of Typhoon Sarika on 18 October 2016. The wind speed and wind direction at the height of 115 m, the translational accelerations on a total of six floors and the angular accelerations on a total of four floors were recorded. The time and frequency domain characteristics of translational acceleration and torsional angular accelerations were analyzed. The amplitude-dependent translational and torsional modal frequencies of the measured building were identified by NExT-ERA, SSI, and RDT methods. The full-scale study is expected to provide useful information on the wind-resistant design of high-rise buildings in typhoon-prone regions.


2022 ◽  
Vol 12 (2) ◽  
pp. 624
Author(s):  
Ji-Hyeon Kim ◽  
Yeun-Chul Park ◽  
Mancheol Kim ◽  
Hyoung-Bo Sim

Tension clamps play an important role in maintaining the track gauge by fixing the rails to the sleepers. Damage to the tension clamps was observed on an urban railway. The cause of the fracturing of the tension clamps was identified and reliability analyses on the fatigue failure of the tension clamps were performed. The stress ranges were estimated by measuring the strain at the locations where most of the fractures occurred during train operation. Afterward, a statistical model of the stress ranges was developed using the measured data. The statistical parameters of the stress ranges for the reliability analysis were estimated based on the field measurement data. The reliability indexes were calculated for the inner and outer rails and for the inside and outside track gauges of each rail. The variations of the reliability index for the years in service and the number of cycles were investigated. The results of the reliability analyses showed a consistency with the field observations.


2022 ◽  
Vol 207 ◽  
pp. 108433
Author(s):  
Hong Hu ◽  
Hideki Kikumoto ◽  
Ryozo Ooka ◽  
Chao Lin ◽  
Bingchao Zhang

2021 ◽  
Vol 15 (1) ◽  
pp. 41-48
Author(s):  
Andrew Gomes ◽  
Ye Tao ◽  
Abdul Bhuiyan ◽  
Don Guan ◽  
Farhad Memarzadeh

Objective: The health and comfort of the indoor population have been impacted by the humidity. While people are increasingly spending more time indoors, the presence of pollutants and lack of proper humidification in indoor air have significant risk factors that may lead to multiple health problems. Methods: By applying the right air purification and/or humidification system, the adverse effects of poor indoor air quality can be minimized. Direct steam addition is a common technique to humidify the indoor air of a building. Carbon dioxide or other acidic process contaminants may dissolve in steam or steam condensate that will consequently decrease the pH and make it corrosive for the steam distribution system. To avoid that, neutralizing amines are added to steam that keeps the pH neutral or slightly alkaline(pH 7.5-9.0). However, neutralizing amines have some toxic effects. OSHA, FDA, and NIOSH prescribe maximum concentration limits for them in indoor air. The Central Utility Plant (CUP) of National Institutes of Health (NIH) uses a 50:50 blend of cyclohexylamine and diethylaminoethanol as neutralizing agents for the steam. Results: The CUP at NIH presents the results of monitoring the concentration level of amines through mass balance, online monitoring at specified location of the steam distribution system and field measurement in humidified indoor air at buildings on campus. Conclusion Through theoretical calculation backed up by field measurement, the amine concentration of indoor air is determined to be well below the FDA regulated limits.


Sign in / Sign up

Export Citation Format

Share Document