scholarly journals Fluoroless and contrast-free catheter ablation without a lead apron in routine clinical practice

2020 ◽  
Vol 10 (1) ◽  
Author(s):  
Takumi J. Matsubara ◽  
Katsuhito Fujiu ◽  
Yu Shimizu ◽  
Tsukasa Oshima ◽  
Jun Matsuda ◽  
...  

Abstract The technique of catheter ablation has been improved within the past few decades, especially by three-dimensional (3D) mapping system. 3D mapping system has reduced radiation exposure but ablation procedures still require fluoroscopy. Our previous study showed the safety and efficacy of catheter ablation based on intracardiac echogram combined with CARTOSOUND/CARTO3 system, however fluoroscopy use for an average of 16 min is required for this procedure. The present study was aimed to reduce radiation exposure to zero and establish a radiation free catheter ablation method with the goal of utilizing it in routine clinical practice. We conducted single center, retrospective study during 2019 April to 2020 February. Consecutive 76 patients were enrolled. In the first 18 cases, the previously reported procedure (CARTOSOUND/CARTO3 method) was used. The remaining 58 cases were transitioned to fluoroless catheter ablation. The procedure time, success rates and complication rates were analyzed. Not only AF patients but atrial flutter (AFL), paroxysmal supraventricular tachycardia (PSVT) and ventricular arrhythmia patients were included. Catheter positioning, catheter visualization and collecting the geometry of each camber of the heart were conducted by using contact force and ICE based geometry on CARTO system without either prior computed tomography (CT) or magnetic resonance image (MRI). In fluoroless group, all catheter ablations were successfully performed without lead aprons. No complications occurred in either group. There were no significant differences in procedure time in any type of procedure (Total procedure time Fluoro-group; 149 ± 51 min vs. Fluoroless-group; 162 ± 43 min, N.S.), (PSVT 170 ± 53 min vs. 162 ± 29 min, N.S.), (AFL 110 ± 70 min vs. 123 ± 43 min, N.S.), (AF 162 ± 43 min vs. 163 ± 32 min, N.S.). The total radiation time was reduced to zero in fluoroless group. Catheter ablation with ICE and 3D mapping system guide without fluoroscopy could be safely performed with a high success rate, without any prior CT/MRI 3D images. Radiation was reduced completely for patients and staff, negating the need for protective wear for operators.

EP Europace ◽  
2017 ◽  
Vol 19 (7) ◽  
pp. 1198-1203 ◽  
Author(s):  
Fabrizio Drago ◽  
Gino Grifoni ◽  
Romolo Remoli ◽  
Mario Salvatore Russo ◽  
Daniela Righi ◽  
...  

2018 ◽  
Vol 3 ◽  
pp. 80-82
Author(s):  
Jonasz Kozielski ◽  
Oskar Kowalski ◽  
Ewa Jędrzejczyk-Patej ◽  
Radosław Lenarczyk ◽  
Aleksandra Konieczny ◽  
...  

2021 ◽  
pp. 1-5
Author(s):  
Maryam Rahman ◽  
Jeremy P. Moore ◽  
John Papagiannis ◽  
Grace Smith ◽  
Chris Anderson ◽  
...  

Abstract Background: Patients with CHD can be exposed to high levels of cumulative ionising radiation. Utilisation of electroanatomic mapping during catheter ablation leads to reduced radiation exposure in the general population but has not been well studied in patients with CHD. This study evaluated the radiation sparing benefit of using three-dimensional mapping in patients with CHD. Methods: Data were retrospectively collected from the Catheter Ablation with Reduction or Elimination of Fluoroscopy multi-institutional registry. Patients with CHD were selected. Those with previous ablations, concurrent diagnostic or interventional catheterisation and unknown arrhythmogenic foci were excluded. The control cohort was matched for operating physician, arrhythmia mechanism, arrhythmia location, weight and age. The procedure time, rate of fluoroscopy use, fluoroscopy time, procedural success, complications, and distribution of procedures per year were compared between the two groups. Results: Fifty-six patients with congenital heart disease and 56 matched patients without CHD were included. The mean total procedure time was significantly higher in patients with CHD (212.6 versus 169.5 minutes, p = 0.003). Their median total fluoroscopy time was 4.4 minutes (compared to 1.8 minutes), and their rate of fluoroscopy use was 23% (compared to 13%). The acute success and minor complication rates were similar and no major complications occurred. Conclusions: With the use of electroanatomic mapping during catheter ablation, fluoroscopy use can be reduced in patients with CHD. The majority of patients with CHD received zero fluoroscopy.


Circulation ◽  
1999 ◽  
Vol 100 (11) ◽  
pp. 1203-1208 ◽  
Author(s):  
Carlo Pappone ◽  
Giuseppe Oreto ◽  
Filippo Lamberti ◽  
Gabriele Vicedomini ◽  
Maria Luisa Loricchio ◽  
...  

2017 ◽  
Vol 38 (suppl_1) ◽  
Author(s):  
S. Laranjo ◽  
M.M. Oliveira ◽  
P. Cunha ◽  
R. Pimenta ◽  
A.S. Delgado ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document