scholarly journals Serum cardiac troponin I levels and ECG/Echo monitoring in breast cancer patients undergoing high-dose (7 g/m2) cyclophosphamide

2001 ◽  
Vol 28 (3) ◽  
pp. 277-282 ◽  
Author(s):  
P Morandi ◽  
PA Ruffini ◽  
GM Benvenuto ◽  
L La Vecchia ◽  
G Mezzena ◽  
...  
CHEST Journal ◽  
2000 ◽  
Vol 118 (2) ◽  
pp. 342-347 ◽  
Author(s):  
Giuseppe Boriani ◽  
Mauro Biffi ◽  
Vittorio Cervi ◽  
Gabriele Bronzetti ◽  
Giorgia Magagnoli ◽  
...  

1998 ◽  
Vol 272 (1) ◽  
pp. 59-67 ◽  
Author(s):  
Fred S. Apple ◽  
Scott W. Sharkey ◽  
Alireza Falahati ◽  
Maryann Murakami ◽  
Naheed Mitha ◽  
...  

2017 ◽  
Vol 59 (3) ◽  
pp. 167-173 ◽  
Author(s):  
E. Dutton ◽  
N. Carmichael ◽  
U. Michal ◽  
P. J. Cripps ◽  
A. Boswood

2017 ◽  
Vol 19 (1) ◽  
pp. 1-13 ◽  
Author(s):  
E. Dutton ◽  
J. Dukes-McEwan ◽  
P.J. Cripps

1999 ◽  
Vol 45 (7) ◽  
pp. 1018-1025 ◽  
Author(s):  
Qinwei Shi ◽  
Mingfu Ling ◽  
Xiaochen Zhang ◽  
Minyuan Zhang ◽  
Lilly Kadijevic ◽  
...  

Abstract Background: Up to a 20-fold variation in serum cardiac troponin I (cTnI) concentration may be observed for a given patient sample with different analytical methods. Because more limited variation is seen for control materials and for purified cTnI, we explored the possibility that cTnI was present in altered forms in serum. Methods: We used four recombinantly engineered cTnI fragments to study the regions of cTnI recognized by the Stratus®, Opus®, and ACCESS® immunoassays. The stability of these regions in serum was analyzed with Western blot. Results: The measurement of several control materials and different forms of purified cTnI using selected commercial assays demonstrated five- to ninefold variation. Both the Stratus and Opus assays recognized the N-terminal portion (NTP) of cTnI, whereas the ACCESS assay recognized the C-terminal portion (CTP) of cTnI. Incubation of recombinant cTnI in normal human serum produced a marked decrease in cTnI concentration as determined with the ACCESS, but not the Stratus, immunoassay. Western blot analysis of the same samples using cTnI NTP- and CTP-specific antibodies demonstrated preferential degradation of the CTP of cTnI. Conclusions: The availability of serum cTnI epitopes is markedly affected by the extent of ligand degradation. The N-terminal half of the cTnI molecule was found to be the most stable region in human serum. Differential degradation of cTnI is a key factor in assay-to-assay variation.


Sign in / Sign up

Export Citation Format

Share Document