Derivative spectrophotometric determination of glibenclamide, mebeverine hydrochloride and clopamide in the presence of their alkaline-induced degradation products

The Analyst ◽  
1990 ◽  
Vol 115 (4) ◽  
pp. 449 ◽  
Author(s):  
Mona M. Bedair ◽  
Mohamed A. Korany ◽  
Mohamed A. Ebdel-Hay ◽  
Azza A. Gazy
1965 ◽  
Vol 43 (11) ◽  
pp. 1807-1811 ◽  
Author(s):  
G. Gyorky ◽  
J. C. Houck

The spectrophotometric determination of protein-bound fucose is badly compromised by spurious chromagens developed from protein degradation products. To minimize the contribution of these spurious products to the color yield of fucose, the glycoprotein was partially hydrolyzed in dilute acid, thus releasing the terminal carbohydrate from the protein moieties, and the residual protein was removed with trichloroacetic acid. That the fucose content of this supernatant was real was confirmed by paper chromatography and spectral studies.The spurious chromagens were shown to result from the interaction of protein degradation products and galactose.


1997 ◽  
Vol 126 (1-2) ◽  
pp. 131-135 ◽  
Author(s):  
K. Sreedhar ◽  
C. S. P. Sastry ◽  
M. Narayana Reddy ◽  
D. G. Sankar

1986 ◽  
Vol 69 (4) ◽  
pp. 608-611
Author(s):  
Mohamed A Korany ◽  
Mona Bedair ◽  
Hoda Mahgoub ◽  
Mahmoud A Elsayed

Abstract A rapid and accurate method for determining acetaminophen and phenacetin in presence of their degradation products is presented. Solutions of these drugs in 0.1N HC1 were analyzed by measuring their second derivative spectral response at 295 nm where the degradation products do not interfere. The mean percent recoveries for mixtures of acetaminophen and/or phenacetin with the corresponding degradation products were 100.2 ± 0.6 and 100.6 ± 1.1, respectively. The method can be used for assessing the stability of the 2 drugs. The proposed method is also applied to the determination of acetaminophen in tablets and syrups.


1979 ◽  
Vol 62 (4) ◽  
pp. 764-768
Author(s):  
Mitsuaki Sano ◽  
Masako Furukawa ◽  
Miyako Kourai ◽  
Isao Tomita

Abstract A method is described for the determination of an organic tin insecticide, Vendex or hexakis(2-methyl-2-phenylpropyl)distannoxane (HMPD). Tin compounds are extracted from the sample homogenate with ethyl ether containing 1% acetic acid. HMPD and its degradation products are separated through a silica gel column, and analyzed by an atomic absorption spectrophotometer coupled with a heated graphite atomizer. By this technique, as little as 5 ng HMPD and its degradation products can be determined with an average recovery of 67–96%.


Sign in / Sign up

Export Citation Format

Share Document