Determination and removal of antibiotics in secondary effluent using a horizontal subsurface flow constructed wetland

2013 ◽  
Vol 15 (4) ◽  
pp. 709 ◽  
Author(s):  
Chunhui Zhang ◽  
Ke Ning ◽  
Wenwen Zhang ◽  
Yuanjie Guo ◽  
Jun Chen ◽  
...  
2010 ◽  
Vol 62 (3) ◽  
pp. 603-614 ◽  
Author(s):  
G. D. Gikas ◽  
V. A. Tsihrintzis

A small-scale horizontal subsurface flow constructed wetland, located in North Greece, was designed and constructed to treat wastewater from a single-family residence. A three-year monitoring program was undertaken to evaluate the performance of this system. The monitoring campaigns were organized every 7 days. Water quality samples were collected at the inlet, at intermediate points (i.e. at the end of each treatment stage) and at the outlet of the system. Temperature, electrical conductivity, pH and DO were measured in-situ with the use of appropriate instruments at the same points of water sample collection. Water samples were analyzed for BOD, COD, TKN, ammonia, nitrate, nitrite, total phosphorus (TP), ortho-phosphate (OP), total suspended solids (TSS) and total coliforms (TC). Mean removal efficiencies for the monitoring period were: 86.5% for BOD, 84.6% for COD, 83.7% for TKN, 82.2% for ammonia, 63.1% for OP, 63.3% for TP, 79.3% for TSS and 99.9% for TC. Furthermore, based on statistical testing, TKN, ammonia and TP removal efficiencies showed dependence on temperature. The paper presents facility description, study details and monitoring results. The study shows that the use of constructed wetlands in wastewater treatment is a good option for single-family residences in rural areas.


2010 ◽  
Vol 37 (3) ◽  
pp. 496-501 ◽  
Author(s):  
K.N. Njau ◽  
M. Renalda

A horizontal subsurface flow constructed wetland (HSSFCW) was employed to remove tannins from the effluent of a tannins extracting company. Two HSSFCW cells with hydraulic retention time (HRT) of 9 d and packed with limestone were used. One cell without macrophytes was used as a control, while the second cell was planted with Phragmites mauritianus . Results indicated that HSSFCW was capable of treating tannin wastewater that has been seeded with primary facultative pond sludge. Tannins and chemical oxygen demand (COD) removal efficiency of 95.9% and 90.6% with outlet concentration of 27 mg/L and 86 mg/L, respectively, were obtained in the planted cell; while the tannins and COD removal efficiency of 91.1% and 89.5% with outlet concentration of 57 mg/L and 96 mg/L, respectively, were obtained in the control cell.


Sign in / Sign up

Export Citation Format

Share Document