A ratiometric electrochemical biosensor for ultrasensitive and highly selective detection of the K-ras gene via exonuclease III-assisted target recycling and rolling circle amplification strategies

2019 ◽  
Vol 11 (32) ◽  
pp. 4146-4156 ◽  
Author(s):  
Qi Xiao ◽  
Jinrong Feng ◽  
Jiawen Li ◽  
Yi Liu ◽  
Dan Wang ◽  
...  

A ratiometric electrochemical biosensor for ultrasensitive and highly selective detection of the K-ras gene via Exo III-assisted target recycling and RCA strategies.

RSC Advances ◽  
2015 ◽  
Vol 5 (12) ◽  
pp. 9123-9129 ◽  
Author(s):  
Fenglei Gao ◽  
Yan Du ◽  
Jingwen Yao ◽  
Yanzhuo Zhang ◽  
Jian Gao

A strategy for electrochemical detection of DNA by exonuclease III-assisted DNA recycling and the rolling circle amplification was developed.


The Analyst ◽  
2014 ◽  
Vol 139 (11) ◽  
pp. 2884-2889 ◽  
Author(s):  
Xingti Liu ◽  
Qingwang Xue ◽  
Yongshun Ding ◽  
Jing Zhu ◽  
Lei Wang ◽  
...  

A sensitive and label-free DNA detection method was developed based on cascade amplification combining exonuclease-III recycling with rolling circle amplification.


2016 ◽  
Vol 8 (9) ◽  
pp. 2106-2111 ◽  
Author(s):  
Erhu Xiong ◽  
Xiaohua Zhang ◽  
Yunqing Liu ◽  
Jiawan Zhou ◽  
Peng Yu ◽  
...  

An electrochemical biosensor for Hg2+ detection was developed based on Exo III-assisted target recycling and hybridization chain reaction amplification strategies.


2021 ◽  
Vol 12 (1) ◽  
Author(s):  
Thanyarat Chaibun ◽  
Jiratchaya Puenpa ◽  
Tatchanun Ngamdee ◽  
Nimaradee Boonapatcharoen ◽  
Pornpat Athamanolap ◽  
...  

AbstractCoronavirus disease 2019 (COVID-19) is a highly contagious disease caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Diagnosis of COVID-19 depends on quantitative reverse transcription PCR (qRT-PCR), which is time-consuming and requires expensive instrumentation. Here, we report an ultrasensitive electrochemical biosensor based on isothermal rolling circle amplification (RCA) for rapid detection of SARS-CoV-2. The assay involves the hybridization of the RCA amplicons with probes that were functionalized with redox active labels that are detectable by an electrochemical biosensor. The one-step sandwich hybridization assay could detect as low as 1 copy/μL of N and S genes, in less than 2 h. Sensor evaluation with 106 clinical samples, including 41 SARS-CoV-2 positive and 9 samples positive for other respiratory viruses, gave a 100% concordance result with qRT-PCR, with complete correlation between the biosensor current signals and quantitation cycle (Cq) values. In summary, this biosensor could be used as an on-site, real-time diagnostic test for COVID-19.


RSC Advances ◽  
2014 ◽  
Vol 4 (51) ◽  
pp. 27091-27097 ◽  
Author(s):  
Qingwang Xue ◽  
Yanqin Lv ◽  
Yuanfu Zhang ◽  
Shuling Xu ◽  
Qiaoli Yue ◽  
...  

A novel label-free amplified fluorescent sensing scheme based on target-responsive dumbbell probe-mediated rolling circle amplification (D-RCA) has been developed for sensitive and selective detection of mercuric ions.


Sign in / Sign up

Export Citation Format

Share Document