scholarly journals Thermal behaviour analysis of a high voltage inverted‐type current transformer

Author(s):  
Caibo Liao ◽  
Zhibin Qiu ◽  
Zhijian Tang ◽  
Jiansheng Li ◽  
Yong Ma ◽  
...  
2013 ◽  
Vol 694-697 ◽  
pp. 785-789
Author(s):  
Yang Gao ◽  
Guo Yan Liang

In this paper, based on the choice of voltage level 500kV for large transformer differential protection of maloperation accident actually as an example, discusses how to improve the reliability and the transformer differential protection with the relationship between pressure test. Analysis found that in order to avoid the excitation transient exciting current transformer differential protection sparked the misoperation, on-site technical personnel in the differential protection setting calculation process, make use of data in conformity with the relevant parameters, rules and standards, familiar with differential protection, also need to understand the characteristics of transformer excitation transient exciting current high-voltage tests, the influence of characteristic more should fully exert the modern PC wave record device, instrument function can improve the actual effect of transformer differential protection. This factory for transformer differential protection for setting, protection greatly improves the reliability. This experience is worth popularizing.


Author(s):  
Liudmyla Zhorniak ◽  
Alexej Afanasiev ◽  
Vitaliy Schus ◽  
Olexij Morozov ◽  
Julia Rudenko

In the article, the authors propose a method for estimating the parameters of theoretical distributions for calculating the indicators of operational reliability. In the article, the authors propose a method for estimating the parameters of theoretical distributions for calculating the indicators of the operational reliability of a solid insulating structure of high-voltage devices, which is a supporting insulating cover for high voltage instrument transformers filled with gas as an insulating liquid. This technique makes it possible to estimate the parameters of a new distribution law, which is chosen on the condition that it does not contradict the existing distribution law with its known parameters. The developed technique makes it possible to obtain the values of the indicators of the operational reliability of high-voltage equipment by determining the parameters of theoretical distributions, if the developer is the data of experimental studies or statistical information as a result of monitoring the operation of insulating structures, taking into account the actual operating conditions of such high-voltage devices.  This makes it possible to take into account the influence of external factors and performance characteristics inherent in instrument transformers, both current and voltage. In the proposed methodology, as an example, a supporting insulating casing is considered, which is during operation in the most unfavorable conditions, such as external pollution, humidification, overvoltage, etc. The theoretical conclusions are confirmed by the results of calculations using the example of the design of a current transformer of the ТОГ-362 series. A more accurate determination of the effectiveness of the proposed method for predicting the parameters of theoretical distribution laws can be achieved by performing an additional series of calculations and experimental tests of specific insulating structures. Thus, it was concluded that it is possible to use the results obtained to assess the operational reliability of both gas-filled instrument transformers and similar high-voltage equipment.


High Voltage ◽  
2019 ◽  
Vol 4 (3) ◽  
pp. 173-177 ◽  
Author(s):  
Arthur F. Andrade ◽  
Edson G. Costa ◽  
Josué M.B. Fernandes ◽  
Helem M.M. Alves ◽  
Cícero R.C. Amorim Filho