Advances in profiling of natural products by triple detection techniques combined with super critical CO2 mobile phases and Sub-2 µm stationary phases

Planta Medica ◽  
2015 ◽  
Vol 81 (16) ◽  
Author(s):  
D Rodriguez Cabaleiro ◽  
P Hong ◽  
G Isaac ◽  
J Yuk ◽  
K Yu ◽  
...  
2017 ◽  
Vol 100 (6) ◽  
pp. 1652-1659 ◽  
Author(s):  
Anna Petruczynik ◽  
Justyna Misiurek ◽  
Tomasz Tuzimski ◽  
Monika Waksmundzka-Hajnos

Abstract An HPLC procedure on a polar reversed-phase column with mobile phases containing ionic liquid (IL) was developed for the analysis of selected alkaloids from different chemical groups. We aimed to obtain optimal conditions for the separation of alkaloids because widely used silica-based stationary phases exhibit a silanol effect, rendering analysis of basic analytes extremely difficult. Retention, separation selectivity, peak symmetry, and system efficiency were examined in various eluent systems containing different concentrations of IL and acetonitrile. The obtained results revealed substantial influence from the concentrations of IL, the organic modifier, and temperature on the retention behavior of the investigated alkaloids. The most selective and efficient chromatographic systems were applied for the analysis of several alkaloids in a plant extract.


2012 ◽  
Vol 66 (3) ◽  
pp. 365-372 ◽  
Author(s):  
Dragana Livaja-Popovic ◽  
Eva Loncar ◽  
Lidija Jevric ◽  
Radomir Malbasa

Quantitative structure-retention relationships (QSRR) have been used to study the chromatographic behavior of some aldopentose. The behavior of aldopentose derivatives was investigated by means of the reversed-phase thin-layer chromatography (RP TLC) on the silica gel impregnated with paraffin oil stationary phases. Binary mixtures of methanol-water, acetone-water and dioxane-water were used as mobile phases. Retention factors, RM0, corresponding to zero percent organic modifier in the aqueous mobile phase was determined. Lipophilicity C0 was calculated as the ratio of the intercept and slope values. There was satisfactory correlation between them and log P values calculated using different theoretical procedures. Some of these correlations offer very good predicting models, which are important for a better understanding of the relationships between chemical structure and retention. The study showed that the hydrophobic parameters RM0 and C0 can be used as a measures of lipophilicity of investigated compounds.


2004 ◽  
Vol 17 (5) ◽  
pp. 335-341 ◽  
Author(s):  
Mária Báthori ◽  
Attila Hunyadi ◽  
Gábor Janicsák ◽  
Imre Máthé

Sign in / Sign up

Export Citation Format

Share Document