Extramedullary Guide Alignment Is not Affected by Obesity in Primary Total Knee Arthroplasty

Author(s):  
Jocelyn Compton ◽  
Jessell Owens ◽  
Jesse Otero ◽  
Nicolas Noiseux ◽  
Timothy Brown

AbstractCoronal alignment of the tibial implant correlates with survivorship of total knee arthroplasty (TKA), especially in obese patients. The purpose of this study was to determine if obesity affects coronal plane alignment of the tibial component when utilizing standard extramedullary tibial guide instrumentation during primary TKA. A retrospective review from June 2017 to February 2018 identified 142 patients (162 primary TKAs). There were 88 patients (100 knees) with body mass index (BMI) < 35 kg/m2 and 54 patients (62 knees) with BMI ≥ 35.0 kg/m2. The cohorts did not differ in age (p = 0.37), gender (p = 0.61), or Charlson's comorbidity index (p = 0.54). Four independent reviewers measured the angle between the base of the tibial component and the mechanical axis of the tibia on the anteroposterior view of long-leg film at first postoperative clinic visit. Outliers were defined as patients with greater than 5 degrees of varus or valgus alignment (n = 0). Reoperations and complications were recorded to 90 days postoperatively. There was no significant difference in mean tibial coronal alignment between the two groups (control alignment 90.8 ± 1.2 degree versus obese alignment 90.8 ± 1.2 degree, p = 0.91). There was no difference in varus versus valgus alignment (p = 0.19). There was no difference in the number of outliers (two in each group, p = 0.73). There was no difference in rate of reoperation (p = 1.0) or complication (p = 0.51). Obesity did not affect coronal plane alignment of the tibial component when using an extramedullary guide during primary TKA in our population.

SICOT-J ◽  
2020 ◽  
Vol 6 ◽  
pp. 36 ◽  
Author(s):  
Victor Pacoret ◽  
Etienne Kalk ◽  
Ludovic Labattut ◽  
Guillaume Girardot ◽  
Emmanuel Baulot ◽  
...  

Introduction: Knee osteoarthritis is the main indication for primary total knee arthroplasty (TKA). It is now accepted that cementless implantation of the femoral component provides equivalent results to cemented one, however, the optimal fixation method of the tibial component remains controversial. The purpose of this study was to compare the survivorship of cemented versus cementless tibial baseplate in primary total knee arthroplasty. Materials and methods: We carried out a retrospective, monocentric study, including 109 TKA (Zimmer® Natural Knee II ultra-congruent mobile-bearing) implanted between 2004 and 2010 for primary osteoarthritis, comparing 2 groups depending on tibial component fixation method, one cemented (n = 68) and one cementless (n = 41). Clinical (Knee Society Rating System (KSS), Hospital for Special Surgery (HSS) scores, range of motion) and radiodiological outcomes were assessed at last follow-up with a minimal follow-up of 5 years. Results: Mean follow-up were 8.14 [5.31–12.7] and 8.06 [5.22–12.02] years, respectively, in cemented and cementless groups. The tibial component survival rate was 100% [95CI: 91.4–100] in the cementless group and 97.1% [95CI: 89.78–99.42] in the cemented group (2 aseptic loosenings) (p = 0.27). Radiolucent lines were present in 31.7% (n = 13) of the cementless and 44.1% (n = 30) of the cemented baseplates (p = 0.2). The postoperative KSS knee score was higher in the cementless group (99 ± 3 vs. 97 ± 7.5; p = 0.02), but there was no significant difference in KSS function, global KSS and HSS scores. Mean range of flexion was 120 ± 10° in the cementless group and 122.5 ± 15° in the cemented group (p = 0.37). No significant differences were found on the radiographic data or on complications. Conclusion: In this study, the survival rate of the tibial component is not influenced by its fixation method at a mean follow-up of 8 years in osteoarthritis, which confirms the reliability of cementless fixation in primary TKA.


2021 ◽  
Vol 29 (4) ◽  
pp. 184-188
Author(s):  
OTÁVIO MONTOVANELLI MONTEIRO ◽  
RODRIGO TURRA PERRONE ◽  
FABRÍCIO NASCIMENTO ALMEIDA ◽  
CID PEREIRA DE MOURA JUNIOR ◽  
SAULO GOMES DE OLIVEIRA ◽  
...  

ABSTRACT Objective: To compare the use of intravenous and topical tranexamic acid (TXA) in unilateral primary total knee arthroplasty (TKA) in relation to blood loss and complications inherent to the medication. Method: Three groups with 14 patients each were constituted, and all of them were operated using the same surgical technique. In Group 1, usual measures for bleeding control were performed. Group 2 patients received TXA topically on the joint surface. In Group 3, intravenous TXA was used. Hemoglobin (HB), hematocrit (HTC), platelets (PLAT), prothrombin time, activated partial thromboplastin time and volume of blood drained observed 24 hours after arthroplasty were compared to the values of tests found before surgery. Results: There was a decrease in the concentration of HB, HTC and PLAT in all groups in relation to the preoperative, however without significant difference. Group 3 had a lower mean volume of drained blood than the other groups, with statistical significance. No adverse effects or thromboembolic events were observed in the groups that received TXA. Conclusion: This study showed superiority in the use of intravenous TXA in decreasing the volume of bleeding, without increasing the risk of thromboembolic events. Level of Evidence I, High quality randomized trial with statistically significant difference or no statistically significant difference but narrow confidence intervals.


2019 ◽  
Vol 101-B (11) ◽  
pp. 1356-1361 ◽  
Author(s):  
Brian P. Chalmers ◽  
Kapil G. Mehrotra ◽  
Rafael J. Sierra ◽  
Mark W. Pagnano ◽  
Michael J. Taunton ◽  
...  

Aims Knee osteonecrosis in advanced stages may lead to joint degeneration. Total knee arthroplasty (TKA) for osteonecrosis has traditionally been associated with suboptimal results. We analyzed outcomes of contemporary TKAs for osteonecrosis, with particular emphasis on: survivorship free from aseptic loosening, any revision, and any reoperation plus the clinical outcomes, complications, and radiological results. Patients and Methods In total, 156 patients undergoing 167 primary TKAs performed for osteonecrosis between 2004 and 2014 at a single institution were reviewed. The mean age at index TKA was 61 years (14 to 93) and the mean body mass index (BMI) was 30 kg/m2 (18 to 51) The mean follow-up was six years (2 to 12). A total of 110 TKAs (66%) were performed for primary osteonecrosis and 57 TKAs (34%) for secondary osteonecrosis. Overall, 15 TKAs (9%) had tibial stems, while 12 TKAs (7%) had femoral stems. Posterior-stabilized designs were used in 147 TKAs (88%) of TKAs. Bivariate Cox regression analysis was conducted to identify risk factors for revision and reoperation. Results Survivorship free from aseptic loosening, any revision, and any reoperation at ten years was 97% (95% confidence interval (CI) 93 to 100), 93% (95% CI 85 to 100), and 82% (95% CI 69 to 93), respectively. No factors, including age, sex, BMI, primary versus secondary osteonecrosis, stem utilization, and constraint, were identified as risk factors for reoperation. Four TKAs (2%) underwent revision, most commonly for tibial aseptic loosening (n = 2). Excluding revisions and reoperations, there was a total of 11 complications (7%), with the most common being a manipulation under anaesthesia (six TKAs, 4%). Mean Knee Society Scores (Knee component) significantly improved from 57 (32 to 87) preoperatively to 91 (49 to 100) postoperatively (p < 0.001). No unrevised TKAs had complete radiolucent lines or radiological evidence of loosening. Conclusion Contemporary cemented TKAs with selective stem utilization for osteonecrosis resulted in durable survivorship, a low complication rate, and reliable improvement in clinical outcomes. Cite this article: Bone Joint J 2019;101-B:1356–1361.


2019 ◽  
Vol 11 (6) ◽  
pp. 1013-1019 ◽  
Author(s):  
De‐si Ma ◽  
Zhi‐wei Wang ◽  
Liang Wen ◽  
Shi‐xiang Ren ◽  
Yuan Lin ◽  
...  

2019 ◽  
Vol 15 (4) ◽  
pp. 287-290
Author(s):  
Ruku Pandit ◽  
Nitasha Sharma

Background: Total knee arthroplasty is the most cost effective and rapidly evolving technique. The success of procedure relies on appropriate sizing of tibial component, for which elaborate information of various dimensions of upper surface of tibia is mandatory. Hence, this study is aiming to generate baseline data on antero-posterior and transverse measurements of medial and lateral condyles and intercondylar area of upper surface of tibia. Methods: The study was conducted in 42 dry human cadaveric tibia with unidentified age and sex, in the Department of Anatomy, College of Medical Sciences and Teaching Hospital, Chitwan. The antero-posterior and transverse measurements of medial and lateral condyles and intercondylar area of tibia were recorded in millimeter (mm) with digital Vernier calipers. The data was analysed using SPSS version 16.0. Results: The antero-posterior and transverse measurements of medial condyle of tibia were 43.00±5.95 mm and 25.21±8.08 mm respectively on the right side and 45.33±5.36 mm and 27.43±8.57 mm respectively on the left side and that of lateral condyle were 37.94±5.64 mm and 25.21±8.71 mm respectively on the right side and 41.03±3.65 mm and 27.06±8.83 mm respectively on the left side. The antero-posterior and transverse measurements of intercondylar area of tibia were 47.49±6.31 mm and 15.71±3.93 mm respectively on the right side and 49.24±6.91 mm and 15.02±3.88 mm respectively on the left side. The variation in the measurements between right and left tibia showed significant difference only for antero-posterior measurement of lateral condyle (p<0.05). Conclusions: The study generates baseline data regarding various anthropometric measurements of upper surface of tibia, which will assist the orthopedic surgeon to create a resected bony surface identical to the tibial component of an implant in unilateral and total knee arthroplasty. Keywords: measurement; morphometric; superior articular surface; tibial condyles.


2019 ◽  
Vol 33 (07) ◽  
pp. 678-684 ◽  
Author(s):  
Fahad Hossain ◽  
Sujith Konan ◽  
Babar Kayani ◽  
Christina Kontoghiorghe ◽  
Toby Barrack ◽  
...  

AbstractThe use of valgus–varus constrained (VVC) implant designs in primary total knee arthroplasty (TKA) is considered in situations of severe deformities, bone loss, and inadequate soft tissue balance. It is not known whether the use of such prosthesis designs may predispose to reduced function owing to its constraining design. The components are usually implanted with diaphyseal stem extensions to dissipate the increased forces. The totally stabilized (TS) implant is a contemporary VVC design with metaphyseal fixation only. It has a conforming articulation with increased rotational freedom compared with conventional VVC designs. The aim of this study was to assess whether the use of the contemporary TS implant with its metaphyseally fixed components would be associated with inferior outcomes compared with conventional standard primary posterior stabilized (PS) implants. We reviewed 38 consecutive complex primary TKAs performed using the metaphyseally fixed TS implant and 76 matched patients receiving primary PS TKA, at a minimum follow-up of 24 months. The mean follow-up was 61.1 months (24–102). Only patients with osteoarthritis were included. Clinical outcome was assessed using range of motion (ROM) and Oxford knee score (OKS). Radiographic assessment was performed using the femorotibial angle (FTA) at 6 weeks followed by assessment of bone–implant interface lucencies at final follow-up. There were no major early postoperative complications. The mean postoperative ROM in the TS and PS groups were 114.1 and 112.0, respectively. There was no difference in the mean ROM and OKS between the two groups. The mean FTA for patients in both groups was within 3° of the expected. There was no evidence of progressive lucencies or implant migration at final follow-up. The metaphyseally fixed TS knee design achieves comparable short-term functional outcomes when compared with conventional PS designs in primary knee arthroplasty. Long-term follow-up studies are required to assess survivorship.


Author(s):  
Changjiao Sun ◽  
Wei Rong ◽  
Ruiyong Du ◽  
Sha Wu ◽  
Pu Liu ◽  
...  

AbstractsMultiple surgical techniques exist to repair iatrogenic medial collateral ligament (MCL) injury during total knee arthroplasty (TKA). The objective of the study is to confirm the clinical effectiveness of meniscus transfer for treatment of iatrogenic MCL midsubstance transection in which remaining MCL is of poor quality, and there is a persistent gap between both ligament ends during TKA. From January 2015 to November 2019, we treated 11 patients with MCL injuries of 882 primary TKAs by meniscus transfer. Another 24 primary TKAs were recruited as a control group. The two groups of patients were comparable for age, gender, body mass index (BMI), Knee Society scoring (KSS), knee function score (KFS), and type of prosthesis comparison without significant difference (p > 0.05). We reviewed the patient's stability, as well as objective measures such as KSS and KFS scores, physical examinations, and radiographs. No patient of either group reported impaired wound healing, joint instability on physical examination, pain, radiographic changes, signs of loosening, and other complications. At the final follow-up, there was no significant difference in terms of KSS (p = 0.780) and KFS (p = 0.612) between the injury group and control group at last follow-up. X-ray image review showed no prosthesis loosening or subsidence for both groups. Based on these results, we are cautiously optimistic that midsubstance transections in which the quality of remaining tendon is weak, there is suspicion of stretching, or there is a persistent gap between both ligament ends that can be reconstructed with meniscus autograft transfer augmentation and an unconstrained implant.


2019 ◽  
Vol 34 (01) ◽  
pp. 047-056
Author(s):  
Takao Kaneko ◽  
Norihiko Kono ◽  
Yuta Mochizuki ◽  
Masaru Hada ◽  
Shinya Toyoda ◽  
...  

AbstractPorous tantalum tibial component is durable with excellent bone ingrowth, higher knee scores, and long-term survivorship. However, to our knowledge, the effect of posterior cruciate-retaining (CR) and posterior cruciate-substituting (PS) porous tantalum tibial component has not been reported. The aim of the current study was to investigate the prosthetic bone quality between CR porous tantalum tibial component and PS using three-dimensional multi-detector-row computed tomography (3D-MDCT). Porous twenty-two (22) CR total knee arthroplasties and 22 PS received 3D-MDCT at every 6 months up to 5.5 years postoperatively to assess prosthetic bone quality (bone marrow contents/tissue volumes [BMC/TV, mg/cm3]) underneath the pegs of porous tantalum modular tibial component. Clinical outcomes (Knee Society score [KSS], Western Ontario and McMaster Universities (WOMAC), FJS-12, Patella score) were evaluated at a minimum follow-up period of 5.5 years. No statistically significant differences were found in age, gender, body mass index, KSS, and BMC/TV volumes in the proximal tibia between the two groups before total knee arthroplasty (TKA). There were also no significant differences between the CR and PS groups with regard to BMC/TV at every 6 months up to 5.5 years after TKA. At 5.5 years postoperatively, there was no significant difference between the two groups in terms of the KSS, WOMAC, forgotten joint score (FJS-12), and Patella score. The present study revealed that the prosthetic bone quality of the CR porous tantalum tibial component and PS were equivalent at every 6 months up to 5.5 years after TKA. This study reflects level II evidence.


2018 ◽  
Vol 32 (10) ◽  
pp. 941-946 ◽  
Author(s):  
Dimitrios S. Evangelopoulos ◽  
Sufian S. Ahmad ◽  
Anna M. Krismer ◽  
Christoph E. Albers ◽  
Sven Hoppe ◽  
...  

AbstractRevision total knee arthroplasty (RTKA) represents an effective treatment for failed TKA, but with less favorable outcomes. Considering the technical complexity and economic burden of RTKA procedures, it is mandatory to investigate current mechanisms and predictors for RTKA failure. The objective of this study is to evaluate the survivorship and determine the predominant causes of failure of RTKA. A total of 146 patients undergoing RTKA between 2003 and 2013 were identified from the institutional database. Revision was defined as surgery in which the whole prostheses (inlay and both femoral and tibial components) required exchange. Median follow-up was 6.3 ± 2.7 years (range: 2.2–10). Patient demographics, year of primary implantation, reasons for revision surgery, implant type, pain, knee mobility, systemic or local postoperative complications, and treatment of the complications were recorded and evaluated. Infection was a major cause of failure followed by aseptic loosening, instability, pain, malalignment, and inlay wear. Following RTKA, Knee Society Score (KSS) (knee score and functional score) demonstrated a significant improvement (p < 0.05). No significant difference in flexion, extension deficit, and KSS was detected between aseptic and septic primary TKAs preoperatively and following first RTKA. Reinfection rate of the septic primary TKAs was 5%. Infection was the major cause of a second revision, reaching as high as 50% in all cases. The results of this study support that septic failure of a primary TKA is likely to occur within the first 2 years following implantation. Septic failure of primary TKA does not influence survival of the revision prosthesis.


Sign in / Sign up

Export Citation Format

Share Document