Is It Reasonable to Perform Isolated SAVR by Residents in the TAVI Era?

Author(s):  
Stephen Gerfer ◽  
Kaveh Eghbalzadeh ◽  
Elmar Kuhn ◽  
Thorsten Wahlers ◽  
Sarah Brinkschröder ◽  
...  

Abstract Background The role of conventional surgical aortic valve replacement (SAVR) is increasingly questioned since the indication for transcatheter aortic valve implantations (TAVIs) is currently extended. While the number of patients referred to SAVR decreases, it is unclear if SAVR should be performed by junior resident surgeons in the course of a heart surgeons training. Methods Patients with isolated aortic valve replacement (AVR) were analyzed with respect to the surgeon's qualification. AVR performed by resident surgeons was compared with AVR by senior surgeons. The collective was analyzed with respect to clinical short-term outcomes comparing full sternotomy (FS) with minimally invasive surgery and ministernotomy (MS) with right anterior thoracotomy (RAT) after a 1:1 propensity score matching. Results The 30-day all-cause mortality was 2.3 and 3.4% for resident versus senior AVR groups, cerebrovascular event rates were 1.1 versus 2.6%, and no cases of significant paravalvular leak were detected. Clinical short-term outcomes between FS and minimally invasive access, as well after MS and RAT were comparable. Conclusion Our current data show feasibility and safety of conventional SAVR procedure performed by resident surgeons in the era of TAVI. Minimally invasive surgery should be trained and performed in higher volumes early in the educational process as it is a safe treatment option.

Author(s):  
Victor Mauri ◽  
Stephen Gerfer ◽  
Elmar Kuhn ◽  
Matti Adam ◽  
Kaveh Eghbalzadeh ◽  
...  

Abstract Background Rapid deployment aortic valve replacement (RDAVR) and transcatheter aortic valve implantation (TAVI) have emerged as increasingly used alternatives to conventional aortic valve replacement to treat patients at higher surgical risk. Therefore, in this single-center study, we retrospectively compared clinical outcomes and hemodynamic performance of two self-expanding biological prostheses, the sutureless and rapid deployment valve (RDV) Perceval-S (PER) and the transcatheter heart valve (THV) ACURATE neo/TF (NEO) in a 1:1 propensity-score-matching (PSM) patient cohort. Methods A total of 332 consecutive patients with symptomatic aortic valve stenosis underwent either singular RDAVR with PER (119) or TAVI with NEO (213) at our institutions between 2012 and 2017. To compare the unequal patient groups, a 1:1 PSM for preoperative data and comorbidities was conducted. Afterward, 59 patient pairs were compared with regard to relevant hemodynamic parameter, relevant paravalvular leak (PVL), permanent postoperative pacemaker (PPM) implantation rate, and clinical postoperative outcomes. Results Postoperative clinical short-term outcomes presented with slightly higher rates for 30-day all-cause mortality (PER = 5.1% vs. NEO = 1.7%, p = 0.619) and major adverse cardiocerebral event in PER due to cerebrovascular events (transient ischemic attack [TIA]-PER = 3.4% vs. TIA-NEO = 1.7%, p = 0.496 and Stroke-PER = 1.7% vs. Stroke-NEO = 0.0%, p = 1). Moreover, we show comparable PPM rates (PER = 10.2% vs. NEO = 8.5%, p = 0.752). However, higher numbers of PVL (mild—PER = 0.0% vs. NEO = 55.9%, p = 0.001; moderate or higher—PER = 0.0% vs. NEO = 6.8%, p = 0.119) after TAVI with NEO were observed. Conclusion Both self-expanding bioprostheses, the RDV-PER and THV-NEO provide a feasible option in elderly and patients with elevated perioperative risk. However, the discussed PER collective showed more postoperative short-term complications with regard to 30-day all-cause mortality and cerebrovascular events, whereas the NEO showed higher rates of PVL.


Author(s):  
Aristidis Lenos ◽  
Anno Diegeler

During the past decade, many surgeons have focused their interest on the development and improvement of minimally invasive techniques for aortic valve replacement. Although the minimally invasive approaches for the treatment of mitral valve disease have been standardized, the preferred route for aortic valve replacement remains a matter of debate. Access through a right minithoracotomy avoids opening the sternum; however, it requires a greater surgical ability and a learning period, even for experienced surgeons. This enhances the role of sutureless prostheses because these devices are associated with easier placement, excellent hemodynamic performance, and acceptable rates of pacemaker implantation and paravalvular leak. Herein, we report a series of 10 consecutive patients who received an EDWARDS INTUITY rapid deployment valve (Edwards Lifesciences, Irvine, CA USA) by a right minithoracotomy.


Author(s):  
Tom C. Nguyen ◽  
Vinod H. Thourani ◽  
Justin Q. Pham ◽  
Yelin Zhao ◽  
Matthew D. Terwelp ◽  
...  

Objective Low ejection fraction (EF < 40%) portends adverse outcomes in patients undergoing valvular heart surgery. The role of traditional median sternotomy aortic valve replacement (SAVR) compared with minimally invasive aortic valve replacement (MIAVR) in this cohort remains incompletely understood. Methods A multi-institutional retrospective review of 1503 patients who underwent SAVR (n = 815) and MIAVR via right anterior thoracotomy (n = 688) from 2011 to 2014 was performed. Patients were stratified into two groups: EF of less than 40% and EF of 40% or more. In each EF group, SAVR and MIAVR patients were propensity matched by age, sex, body mass index, race, diabetes, hypertension, dyslipidemia, dialysis, cerebrovascular disease, cardiovascular disease, cerebro-vascular accident, peripheral vascular disease, last creatinine level, EF, previous MI and cardiogenic shock, and the Society for Thoracic Surgeons (STS) score. Results Among patients with an EF of 40% or more (377 pairs), patients who underwent MIAVR compared with SAVR had decreased intensive care unit hours (56.8% vs 84.6%, P < 0.001), postoperative length of stay (7.1 vs 7.9 days, P = 0.04), incidence of atrial fibrillation (18.8% vs 38.7%, P < 0.001), bleeding (0.8% vs 3.2%, P = 0.04), and a trend toward decreased 30-day mortality (0.3% vs 1.3%, P = 0.22). The STS scores were largely equivalent in patients undergoing MIAVR compared with SAVR (2.4% vs 2.6%, P = 0.09). In patients with an EF of less than 40% (35 pairs), there was no difference in intensive care unit hours (69% vs 72.6%, P = 0.80), postoperative length of stay (10.3 vs 7.2 days, P = 0.13), 30-day mortality (3.8% vs 0.8%, P = 0.50), or the STS score (3.3% vs 3.2%, P = 0.68). Conclusions Minimally invasive aortic valve replacement in patients with preserved EF was associated with improved short-term outcomes compared with SAVR. In patients with left ventricular dysfunction, short-term outcomes between MIAVR and SAVR are largely equivalent.


Author(s):  
Mattia Glauber ◽  
Lorenzo Di Bacco ◽  
Jose Cuenca ◽  
Roberto Di Bartolomeo ◽  
Max Baghai ◽  
...  

Objective To report the early and mid-term results of patients who underwent minimally invasive aortic valve replacement (MI-AVR) with a sutureless prosthesis from an international prospective registry. Methods Between March 2011 and September 2018, among 957 patients included in the prospective observational SURE-AVR (Sorin Universal REgistry on Aortic Valve Replacement) registry, 480 patients underwent MI-AVR with self-expandable Perceval aortic bioprosthesis (LivaNova PLC, London, UK) in 29 international institutions through either minithoracotomy ( n = 266) or ministernotomy ( n = 214). Postoperative, follow-up, and echocardiographic outcomes were analyzed for all patients. Results Patient age was 76.1 ± 7.1 years; 64.4% were female. Median EuroSCORE I was 7.9% (interquartile range [IQR], 4.8 to 10.9). Median cardiopulmonary bypass and cross-clamp times were 81 minutes (IQR 64 to 100) and 51 minutes (IQR 40 to 63). First successful implantation was achieved in 97.9% of cases. Two in-hospital deaths occurred, 1 for noncardiovascular causes and 1 following a disabling stroke. In the early (≤30 days) period, stroke rate was 1.4%. Three early explants were reported: 2 due to nonstructural valve dysfunction (NSVD) and 1 for malpositioning. One mild and 1 moderate paravalvular leak were reported. In 16 patients (3.3%) pacemaker implantation was needed. Mean follow-up was 2.4 years (maximum = 7 years). During follow-up 5 explants were reported, 3 due to endocarditis and 2 due to NSVD. Follow-up stroke rate was 2.5%. Three structural valve deteriorations not requiring reintervention were reported. Five-year survival was 91.45%. Conclusions In this large prospective international registry, MI-AVR with Perceval valve confirmed to be safe, reproducible, and effective in an intermediate-risk population, providing excellent clinical recovery both in early and mid-term follow-up.


Author(s):  
Giovanni Concistrè ◽  
Giuseppe Santarpino ◽  
Steffen Pfeiffer ◽  
Pierandrea Farneti ◽  
Antonio Miceli ◽  
...  

Objective Important comorbid conditions in patients referred for aortic valve replacement (AVR) require less invasive strategies. We describe our initial experience with the Perceval S (Sorin Group, Saluggia, Italy) and 3f Enable (Medtronic, Minneapolis, MN USA) sutureless aortic bioprostheses. Methods We compared intraoperative data, postoperative clinical outcomes, and echocardiographic results from patients receiving a Perceval S ( P group; n = 97) or a 3f Enable (E group; n = 32) prosthesis in two cardiac surgery departments (Nuremberg, Germany, and Massa, Italy). Results Baseline patient characteristics were similar in both groups, except for mean ± SD body surface area ( P group = 2.01 ± 2.9 m2, E group = 1.83 ± 3.8 m2; P < 0.001). Sixty-five patients (67%) in the P group and 19 patients (59.5%) in the E group ( P = 0.22) underwent minimally invasive AVR with either ministernotomy or right anterior minithoracotomy approach. Concomitant procedures were performed in 37 patients (38%) in the P group and 9 patients (28%) in the E group ( P = 0.56). In-hospital mortality was 2%. The mean ± SD prosthesis diameter was 23.5 ± 1.4 mm ( P group) compared with 22.1 ± 2 mm (E group) ( P < 0.001). In isolated AVR, aortic cross-clamp time was 36 ± 12.7 minutes in the P group and 66 ± 18 minutes in the E group ( P < 0.001). At a mean ± SD follow-up of 8.3 ± 4.5 months, survival was 97% (one death in the P group). In five patients ( P group = 1, E group = 4), a moderate paravalvular leak was present ( P = 0.013). The mean ± SD transvalvular gradient was 9.1 ± 3.3 mm Hg with the Perceval S and 11.2 ± 5.2 mm Hg with the 3f Enable ( P = 0.017). Conclusions Aortic valve replacement with sutureless aortic bioprosthesis is feasible, also with a minimally invasive approach. The Perceval S showed lower operative times and moderate paravalvular leaks and lower mean transvalvular gradients than did the 3f Enable, related to the larger diameter of the Perceval S implanted. Both prostheses showed an excellent hemodynamic performance. This new technology needs long-term follow-up.


Author(s):  
Farhad Bakhtiary ◽  
Ali El-Sayed Ahmad ◽  
Mohamed Amer ◽  
Saad Salamate ◽  
Sami Sirat ◽  
...  

Objective Right anterior minithoracotomy is a promising technique for aortic valve replacement and has shown excellent results in terms of mortality and morbidity. Against this background, we analyzed our institutional experience in this technique during the last 3 years. Methods Between April 2017 and March 2019, 513 consecutive all comers with aortic valve disease underwent video-assisted minimally invasive aortic valve replacement through a 3-cm skin incision as right anterior minithoracotomy at our institution. A camera and automatic fastener technology were used for the valve implantation in all patients. Clinical data were prospectively entered into our institutional database. Results Cardiopulmonary bypass time accounted for 68 ± 24 min and the myocardial ischemic time 38 ± 12 minutes. Thirty-day mortality and overall mortality was 0.4% (2 patients) and 1.4% (7 patients), respectively. Postoperative cerebrovascular events were noted in 8 patients (1.5%). Intensive care stay and hospital stay were 2 ± 2 and 9 ± 7 days, respectively. Pacemaker implantation, injury of the right internal mammary artery, and conversion to full sternotomy were noted in 7 patients (1.4%), 3 patients (0.6%), and 1 patient (0.2%), respectively. Paravalvular leak need to intervention was noted in 2 patients (0.4%). Rethoracotomy rate was 2% (11 patients). Transient postoperative dialysis was necessary for 14 patients (3%). Conclusions Video-assisted minimally invasive aortic valve replacement through the right anterior minithoracotomy is a safe approach and yields excellent outcomes in high-volume centers. The use of a camera and automatic fastener technology facilitates this procedure.


Sign in / Sign up

Export Citation Format

Share Document