Discussion of “Design Method of Time-Dependent Local Scour at Circular Bridge Pier” by Md. Faruque Mia and Hiroshi Nago

2004 ◽  
Vol 130 (12) ◽  
pp. 1211-1213 ◽  
Author(s):  
Giuseppe Oliveto ◽  
Jens Unger ◽  
Willi H. Hager
2015 ◽  
Vol 5 (1) ◽  
pp. 9-15
Author(s):  
Shiv Kumar Yadav ◽  
◽  
Shri Ram ◽  

1994 ◽  
pp. 71-79 ◽  
Author(s):  
Shoji Fukuoka ◽  
Kunihiro Tomita ◽  
Tetsuo Hotta ◽  
Tomohiro Miyagawa

2005 ◽  
Vol 131 (2) ◽  
pp. 97-105 ◽  
Author(s):  
Giuseppe Oliveto ◽  
Willi H. Hager
Keyword(s):  

2021 ◽  
Vol 248 ◽  
pp. 01015
Author(s):  
Zhejiang Chen ◽  
Liang Liu ◽  
Yonglin Hu ◽  
Nan Ye ◽  
Xiaoli Shen ◽  
...  

Because of the problem of local scour caused by the change of the flow structure caused by the water-resistance of the column bridge pier, the theoretical analysis, and indoor water tank test were used to study the effect of installing a new anti-scouring device in front of the bridge pier on the local scour reduction effect; the influence of the main design parameters such as the height of the protective device, the angle of the protective device and the distance from the protective device to the bridge pier on the local scour of the bridge pier was selected, and the optimal parameter design combination was selected. The test results show that: under the same water flow conditions, the maximum scour depth reduction rate of the measuring point under the protection of the protective device is 48.4% to 74.2% compared with the unprotected scour; the reduction rate of the bridge pier is relative to the relative height of the device and the device equivalent. The angle and the distance between the device and the bridge pier are related, and the shock reduction rate decreases with the increase of the flow intensity. In the test range, the ratio of the device height to the water depth is 2/3, the device angle is 60 °, and the distance from the bridge pier is 3. When the diameter of the pier is doubled, the effect of reducing the impact on the pier is the best.


1989 ◽  
Author(s):  
Huang Xiaoyan ◽  
Wang Qinghuan ◽  
Zhang Chao

In order to develop a CAD computer code system for centrifugal compressor, a numerical technique for design and flow analysis of vaned diffusers has been introduced in this paper. The design of diffusers has been performed by a streamline extension method. The velocity and pressure distributions at design and off-design operating modes have been calculated by a time-dependent finite difference scheme and have been corrected by boundary layer calculations. The numerical results are compared with experimental measurements, and the agreement is satisfactory.


Sign in / Sign up

Export Citation Format

Share Document