Assessment of Potential Seismic Damage to Residential Unreinforced Masonry Buildings in Northern Illinois

Author(s):  
Soliman Khudeira ◽  
Jamshid Mohammadi
Author(s):  
Amaryllis Mouyiannou ◽  
Andrea Penna ◽  
Maria Rota ◽  
Francesco Graziotti ◽  
Guido Magenes

The seismic capacity of a structure is a function of the characteristics of the system as well as of its state, which is mainly affected by previous damage and deterioration. The cumulative damage from repeated shocks (for example during a seismic sequence or due to multiple events affecting an unrepaired building stock) affects the vulnerability of masonry buildings for subsequent events. This paper proposes an analytical methodology for the derivation of state-dependent fragility curves, taking into account cumulated seismic damage, whilst neglecting possible ageing effects. The methodology is based on nonlinear dynamic analyses of an equivalent single degree of freedom system, properly calibrated to reproduce the static and dynamic behaviour of the structure. An application of the proposed methodology to an unreinforced masonry case study building is also presented. The effect of cumulated damage on the seismic response of this prototype masonry building is further studied by means of nonlinear dynamic analyses with the accelerograms recorded during a real earthquake sequence that occurred in Canterbury (New Zealand) between 2010 and 2012.


2010 ◽  
Vol 452-453 ◽  
pp. 105-108 ◽  
Author(s):  
Hong Fu Chen ◽  
Bai Tao Sun

During Wenchuan Ms 8.0 earthquake, masonry buildings have suffered severely damaged and collapsed, causing heavy casualties and huge economic losses. In this paper, based on seismic site survey data, some new phenomena and characteristics of earthquake damage in comparison with the 1976 Tangshan earthquake, such as seismic damage of large space buildings, inclined or “X” shaped crack in wall between windows or spandrel wall, stair damage, falling of precast reinforced concrete slab and horizontal crack at the bottom of structure, are discussed in detail. Then, the impact factors of seismic capacity of masonry building in Wenchuan earthquake, including construction age, seismic fortification, bay size, floor (roof) form, layer number, thickness of bearing wall are analyzed, respectively; Finally, some recommendations on seismic design and reconstruction of masonry structure by the seismic design code are proposed.


Sign in / Sign up

Export Citation Format

Share Document