Identification of failure mechanisms in existing unreinforced masonry buildings in rural areas after April 4, 2019 earthquake in Turkey

2021 ◽  
pp. 102586
Author(s):  
Burak YÖN
2021 ◽  
Author(s):  
Marco Nale ◽  
Fabio Minghini ◽  
Andrea Chiozzi ◽  
Antonio Tralli

Abstract The unreinforced masonry buildings can be present frequent local failure mechanisms and represent a serious life-safety hazard as recent strong earthquakes have shown. Compared to new building, existing unreinforced masonry buildings prone to be more vulnerable, not only because they have been designed without seismic or limited loading requirements, but also because horizontal structures and connections amid the walls are not always suitable. Out-of-plane collapse can be caused by important slenderness of walls also when connections are effective. The purpose of this paper is to evaluate fragility functions for unreinforced masonry walls in the presence of local failure mechanisms considering the out-of-plane response. The wall response, very often, can be idealized as rigid bodies undergoing rocking motion. Depending on its configuration, a wall is assumed either as a rigid body undergoing simple one-sided rocking or an assembly of two coupled rigid bodies rocking along their common edge. A set of 44 ground motions from earthquake events occurred from 1972 to 2017 in Italy is used in this study. The likelihood of collapse is calculated via Multiple Stripe Analysis (MSA) from a given wall undergoing a specific ground motion. Later, the single fragility functions are suitably combined to define a typological fragility function for a class of buildings. The procedure is applied to a historical aggregate in the city center of Ferrara (Italy) as a case study. The fragility functions developed in this research can be a very helpful tool for estimating damage and economic loss for unreinforced masonry buildings and for a seismic assessment on a regional scale.


Author(s):  
Marco Nale ◽  
Fabio Minghini ◽  
Andrea Chiozzi ◽  
Antonio Tralli

AbstractUnreinforced masonry buildings undergoing seismic actions often exhibit local failure mechanisms which represent a serious life-safety hazard, as recent strong earthquakes have shown. Compared to new buildings, older unreinforced masonry buildings are more vulnerable, not only because they have been designed without or with limited seismic loading requirements, but also because horizontal structures and connections amid the walls are not always effective. Also, Out-Of-Plane (OOP) mechanisms can be caused by significant slenderness of the walls even if connections are effective. The purpose of this paper is to derive typological fragility functions for unreinforced masonry walls considering OOP local failure mechanisms. In the case of slender walls with good material properties, the OOP response can be modeled with reference to an assembly of rigid bodies undergoing rocking motion. In particular, depending on its configuration, a wall is assumed either as a single rigid body undergoing simple one-sided rocking or a system of two coupled rigid bodies rocking along their common edge. A set of 44 ground motions from earthquake events occurred from 1972 to 2017 in Italy is used in this study. The likelihood of collapse is calculated via Multiple Stripe Analysis (MSA) from a given wall undergoing a specific ground motion. Then, the single fragility functions are suitably combined to define a typological fragility function for a class of buildings. The procedure is applied to a historical aggregate in the city center of Ferrara (Italy) as a case study. The fragility functions developed in this research can be a helpful tool for assessing seismic damage and economic losses in unreinforced masonry buildings on a regional scale.


2013 ◽  
Vol 13 (2) ◽  
pp. 329-337 ◽  
Author(s):  
Y. S. Tama ◽  
A. Solak ◽  
N. Çetinkaya ◽  
G. Şen ◽  
S. Yılmaz ◽  
...  

Abstract. Van, a city in Eastern Anatolian Turkey, was hit by two earthquakes with magnitudes of Mw = 7.2 and Mw = 5.6 in October and November 2011. Both earthquakes caused extensive damage to many buildings. Unreinforced masonry buildings, especially in rural areas, suffered from those earthquakes extensively as in many other cases observed in Turkey during other previous earthquakes. This paper presents a site survey of damaged masonry buildings. Reasons for the wide spread damages are discussed in the paper.


2012 ◽  
Vol 12 (11) ◽  
pp. 3337-3342 ◽  
Author(s):  
D. Güney

Abstract. Earthquakes, which are unavoidable natural phenomena in Turkey, have often produced economic and social disaster. The latest destructive earthquakes happened in Van city. Van, Turkey, earthquakes with M = 7.2 occurred on 23 October 2011 at 13:41 (local time), whose epicenter was about 16 km north of Van (Tabanlı village) and M = 5.6 on 9 November 2011 epicentered near the town of Edremit south of Van in eastern Turkey and caused the loss of life and heavy damages. Both earthquakes killed 644 people and 2608 people were injured. Approximately 4000 buildings collapsed or were seriously damaged. The majority of the damaged structures were seismically insufficient, unreinforced masonry and adobe buildings in rural areas. In this paper, site surveys of the damaged masonry and adobe buildings are presented and the reasons for the caused damages are discussed in detail.


Sign in / Sign up

Export Citation Format

Share Document