scholarly journals Spectral analysis of x-ray emission created by intense laser irradiation of copper materialsa)

2012 ◽  
Vol 83 (10) ◽  
pp. 10E114 ◽  
Author(s):  
C. M. Huntington ◽  
C. C. Kuranz ◽  
G. Malamud ◽  
R. P. Drake ◽  
H.-S. Park ◽  
...  
2007 ◽  
Vol 14 (6) ◽  
pp. 062704 ◽  
Author(s):  
H. A. Sumeruk ◽  
S. Kneip ◽  
D. R. Symes ◽  
I. V. Churina ◽  
A. V. Belolipetski ◽  
...  

2001 ◽  
Vol 34 (10) ◽  
pp. L313-L320 ◽  
Author(s):  
T D Donnelly ◽  
M Rust ◽  
I Weiner ◽  
M Allen ◽  
R A Smith ◽  
...  

Author(s):  
Sophie Desmons ◽  
Caroline Delfosse ◽  
Philippe Rochon ◽  
Bruno Buys ◽  
Guillaume Penel ◽  
...  
Keyword(s):  

Metals ◽  
2021 ◽  
Vol 11 (8) ◽  
pp. 1153
Author(s):  
Ivan Pavlenko ◽  
Jozef Zajac ◽  
Nadiia Kharchenko ◽  
Ján Duplák ◽  
Vitalii Ivanov ◽  
...  

This article deals with improving the wear resistance of multilayer coatings as a fundamental problem in metal surface treatment, strengthening elements of cutting tools, and ensuring the reliability of machine parts. It aims to evaluate the wear depth for multilayer coatings by the mass loss distribution in layers. The article’s primary purpose is to develop a mathematical method for assessing the value of wear for multilayer steel-based coatings. The study material is a multilayer coating applied to steel DIN C80W1. The research was performed using up-to-date laboratory equipment. Nitrogenchroming has been realized under overpressure in two successive stages: nitriding for 36 h at temperature 540 °C and chromizing during 4 h at temperature 1050 °C. The complex analysis included several options: X-ray phase analysis, local micro-X-ray spectral analysis, durometric analysis, and determination of wear resistance. These analyses showed that after nitrogenchroming, the three-layer protective coating from Cr23C6, Cr7C3, and Cr2N was formed on the steel surface. Spectral analysis indicated that the maximum amount of chromium 92.2% is in the first layer from Cr23C6. The maximum amount of carbon 8.9% characterizes the layer from Cr7C3. Nitrogen is concentrated mainly in the Cr2N layer, and its maximum amount is 9.4%. Additionally, it was determined that the minimum wear is typical for steel DIN C80W1 after nitrogenchroming. The weight loss of steel samples by 25 mg was obtained. This value differs by 3.6% from the results evaluated analytically using the developed mathematical model of wear of multilayer coatings after complex metallization of steel DIN C80W1. As a result, the impact of the loading mode on the wear intensity of steel was established. As the loading time increases, the friction coefficient of the coated samples decreases. Among the studied samples, plates from steel DIN C80W1 have the lowest friction coefficient after nitrogenchroming. Additionally, a linear dependence of the mass losses on the wearing time was obtained for carbide and nitride coatings. Finally, an increase in loading time leads to an increase in the wear intensity of steels after nitrogenchroming. The achieved scientific results are applicable in developing methods of chemical-thermal treatment, improving the wear resistance of multilayer coatings, and strengthening highly loaded machine parts and cutting tools.


2015 ◽  
Vol 08 (05) ◽  
pp. 1550018 ◽  
Author(s):  
Shupeng Liu ◽  
Na Chen ◽  
Fufei Pang ◽  
Zhengyi Chen ◽  
Tingyun Wang

Purpose: This work focused on the investigation the hyperthermia performance of the carbon-coated magnetic particles (CCMPs) in laser-induced hyperthermia. Materials and methods: We prepared CCMPs using the organic carbonization method, and then characterized them with transmission electron microscopy (TEM), ultraviolet-visible (UV-Vis) spectrophotometry, vibrating sample magnetometer (VSM) and X-ray diffraction (XRD). In order to evaluate their performance in hyperthermia, the CCMPs were tested in laser-induced thermal therapy (LITT) experiments, in which we employed a fully distributed fiber Bragg grating (FBG) sensor to profile the tissue's dynamic temperature change under laser irradiation in real time. Results: The sizes of prepared CCMPs were about several micrometers, and the LITT results show that the tissue injected with the CCMPs absorbed more laser energy, and its temperature increased faster than the contrast tissue without CCMPs. Conclusions: The CCMPs may be of great help in hyperthermia applications.


TANSO ◽  
2009 ◽  
Vol 2009 (236) ◽  
pp. 2-8 ◽  
Author(s):  
Yasuji Muramatsu ◽  
Ryusuke Harada ◽  
Muneyuki Motoyama ◽  
Eric M. Gullikson

2001 ◽  
Vol 63 (2) ◽  
Author(s):  
V. Kumarappan ◽  
M. Krishnamurthy ◽  
D. Mathur ◽  
L. C. Tribedi

2018 ◽  
Vol 481 (1) ◽  
pp. 639-644 ◽  
Author(s):  
Jiachen Jiang (姜嘉陈) ◽  
Dominic J Walton ◽  
Michael L Parker ◽  
Andrew C Fabian
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document