scholarly journals Magnetic field dependence of the internal quality factor and noise performance of lumped-element kinetic inductance detectors

2016 ◽  
Vol 109 (14) ◽  
pp. 143503 ◽  
Author(s):  
D. Flanigan ◽  
B. R. Johnson ◽  
M. H. Abitbol ◽  
S. Bryan ◽  
R. Cantor ◽  
...  
2018 ◽  
Vol 610 ◽  
pp. A45 ◽  
Author(s):  
H. McCarrick ◽  
G. Jones ◽  
B. R. Johnson ◽  
M. H. Abitbol ◽  
P. A. R. Ade ◽  
...  

Aims. Lumped-element kinetic inductance detectors (LEKIDs) are an attractive technology for millimeter-wave observations that require large arrays of extremely low-noise detectors. We designed, fabricated and characterized 64-element (128 LEKID) arrays of horn-coupled, dual-polarization LEKIDs optimized for ground-based CMB polarimetry. Our devices are sensitive to two orthogonal polarizations in a single spectral band centered on 150 GHz with Δν∕ν = 0.2. The 65 × 65 mm square arrays are designed to be tiled into the focal plane of an optical system. We demonstrate the viability of these dual-polarization LEKIDs with laboratory measurements. Methods. The LEKID modules are tested with an FPGA-based readout system in a sub-kelvin cryostat that uses a two-stage adiabatic demagnetization refrigerator. The devices are characterized using a blackbody and a millimeter-wave source. The polarization properties are measured with a cryogenic stepped half-wave plate. We measure the resonator parameters and the detector sensitivity, noise spectrum, dynamic range, and polarization response. Results. The resonators have internal quality factors approaching 1 × 106. The detectors have uniform response between orthogonal polarizations and a large dynamic range. The detectors are photon-noise limited above 1 pW of absorbed power. The noise-equivalent temperatures under a 3.4 K blackbody load are <100 μK √s. The polarization fractions of detectors sensitive to orthogonal polarizations are >80%. The entire array is multiplexed on a single readout line, demonstrating a multiplexing factor of 128. The array and readout meet the requirements for 4 arrays to be read out simultaneously for a multiplexing factor of 512. Conclusions. This laboratory study demonstrates the first dual-polarization LEKID array optimized specifically for CMB polarimetry and shows the readiness of the detectors for on-sky observations.


2017 ◽  
Vol 110 (22) ◽  
pp. 222601 ◽  
Author(s):  
G. Jones ◽  
B. R. Johnson ◽  
M. H. Abitbol ◽  
P. A. R. Ade ◽  
S. Bryan ◽  
...  

1988 ◽  
Vol 49 (C8) ◽  
pp. C8-461-C8-462 ◽  
Author(s):  
H. Fütterer ◽  
T. Yohannes ◽  
H. Bach ◽  
J. Pelzl ◽  
K. Nahm ◽  
...  

1991 ◽  
Vol 58 (11) ◽  
pp. 1205-1207 ◽  
Author(s):  
R. H. Ono ◽  
L. F. Goodrich ◽  
J. A. Beall ◽  
M. E. Johansson ◽  
C. D. Reintsema

2021 ◽  
Vol 103 (5) ◽  
Author(s):  
Alejandro Ayala ◽  
José Luis Hernández ◽  
L. A. Hernández ◽  
Ricardo L. S. Farias ◽  
R. Zamora

Sign in / Sign up

Export Citation Format

Share Document