Role of soluble and platelet-bound P-selectin in discriminating cardiac from noncardiac chest pain at presentation in the emergency department

2000 ◽  
Vol 139 (2) ◽  
pp. 0320-0328 ◽  
Author(s):  
Paul A. Gurbel ◽  
Dean J. Kereiakes ◽  
Margaret R. Dalesandro ◽  
Raymond D. Bahr ◽  
Christopher M. O[rsquo ]Connor ◽  
...  
Author(s):  
Petra M.J.C. Kuijpers ◽  
Johan Denollet ◽  
Hein J.J. Wellens ◽  
Harry M. Crijns ◽  
Adriaan Honig

2000 ◽  
Vol 139 (2) ◽  
pp. 320-328 ◽  
Author(s):  
Paul A Gurbel ◽  
Dean J Kereiakes ◽  
Margaret R Dalesandro ◽  
Raymond D Bahr ◽  
Christopher M O'Connor ◽  
...  

2010 ◽  
Vol 38 (5) ◽  
pp. 1772-1779 ◽  
Author(s):  
M Orak ◽  
M Üstündağ ◽  
C Güloğlu ◽  
Ö Alyan ◽  
MB Sayhan

2012 ◽  
Vol 58 (8) ◽  
pp. 1208-1214 ◽  
Author(s):  
Volkher Scharnhorst ◽  
Krisztina Krasznai ◽  
Marcel van 't Veer ◽  
Rolf H Michels

Abstract BACKGROUND New-generation high-sensitivity assays for cardiac troponin have lower detection limits and less imprecision than earlier assays. Reference 99th-percentile cutoff values for these new assays are also lower, leading to higher frequencies of positive test results. When cardiac troponin concentrations are minimally increased, serial testing allows discrimination of myocardial infarction from other causes of increased cardiac troponin. We assessed various measures of short-term variation, including absolute concentration changes, reference change values (RCVs), and indices of individuality (II) for 2 cardiac troponin assays in emergency department (ED) patients. METHODS We collected blood from patients presenting with cardiac chest pain upon arrival in the ED and 2, 6, and 12 h later. Cardiac troponin was measured with the high-sensitivity cardiac troponin T (hs-cTnT) assay (Roche Diagnostics) and a sensitive cTnI assay (Siemens Diagnostics). Cardiac troponin results from 67 patients without acute coronary syndrome or stable angina were used in calculating absolute changes in cardiac troponin, RCVs, and II. RESULTS The 95th percentiles for absolute change in cardiac troponin were 8.3 ng/L for hs-cTnT and 28 ng/L for cTnI. Within-individual and total CVs were 11% and 14% for hs-cTnT and 18% and 21% for cTnI, respectively. RCVs were 38% (hs-cTnT) and 57% (cTnI). The corresponding log-normal RCVs were +46%/−32% for hs-cTnT and +76%/−43% for cTnI. II values were 0.31 (cTnI) and 0.12 (hs-cTnT). CONCLUSIONS The short-term variations and IIs of cardiac troponin were low in ED patients free of ischemic myocardial necrosis. The detection of cardiac troponin variation exceeding reference thresholds can help to identify ED patients with acute myocardial necrosis whereas variation within these limits renders acute coronary syndrome unlikely.


1993 ◽  
Vol 38 (10) ◽  
pp. 1909-1914 ◽  
Author(s):  
Catherine Gignoux ◽  
Richard Bost ◽  
Jean Hostein ◽  
Yves Turberg ◽  
Philippe Denis ◽  
...  

2016 ◽  
Vol 10 (1) ◽  
pp. 205-211
Author(s):  
Firas Yassin ◽  
Chris Sawh ◽  
Pankaj Garg

There is increasing role of computed tomographic (CT) in the assessment of acute chest pain in the emergency department especially when the diagnosis is not clear. We report a case where non ECG gated contrast enhanced CT in the emergency department for rule-out of pulmonary embolus guided to the actual diagnosis, which was, acute coronary event, as evidenced by the presence of perfusion defect.


Sign in / Sign up

Export Citation Format

Share Document