Evaluation of Existing Heat Transfer Correlations in Designing Helical Coil Evaporators for Low-Temperature Organic Rankine Cycles via Inverse Design Approach

2018 ◽  
Vol 40 (13-14) ◽  
pp. 1137-1152 ◽  
Author(s):  
Alihan Kaya ◽  
Marija Lazova ◽  
George Kosmadakis ◽  
Steven Lecompte ◽  
Michel De Paepe
Energies ◽  
2020 ◽  
Vol 13 (4) ◽  
pp. 821
Author(s):  
Qin-Liu Cao ◽  
Wei-Tao Wu ◽  
Wen-He Liao ◽  
Feng Feng ◽  
Mehrdad Massoudi

In general, rheological properties of gelled fuels change dramatically when temperature changes. In this work, we investigate flow and heat transfer of water-gel in a straight pipe and a tapered injector for non-isothermal conditions, which mimic the situations when gelled fuels are used in propulsion systems. The gel-fluid is modeled as a non-Newtonian fluid, where the viscosity depends on the shear rate and the temperature; a correlation fitted with experimental data is used. For the fully developed flow in a straight pipe with heating, the mean apparent viscosity at the cross section when the temperature is high is only 44% of the case with low temperature; this indicates that it is feasible to control the viscosity of gel fuel by proper thermal design of pipes. For the flow in the typical tapered injector, larger temperature gradients along the radial direction results in a more obvious plug flow; that is, when the fuel is heated the viscosity near the wall is significantly reduced, but the effect is not obvious in the area far away from the wall. Therefore, for the case of the tapered injector, as the temperature of the heating wall increases, the mean apparent viscosity at the outlet decreases first and increases then due to the high viscosity plug formed near the channel center, which encourages further proper design of the injector in future. Furthermore, the layer of low viscosity near the walls plays a role similar to lubrication, thus the supply pressure of the transport system is significantly reduced; the pressure drop for high temperature is only 62% of that of low temperature. It should be noticed that for a propellent system the heating source is almost free; therefore, by introducing a proper thermal design of the transport system, the viscosity of the gelled fuel can be greatly reduced, thus reducing the power input to the supply pressure at a lower cost.


Energies ◽  
2019 ◽  
Vol 12 (10) ◽  
pp. 1853 ◽  
Author(s):  
Pavel Neuberger ◽  
Radomír Adamovský

The efficiency of a heat pump energy system is significantly influenced by its low-temperature heat source. This paper presents the results of operational monitoring, analysis and comparison of heat transfer fluid temperatures, outputs and extracted energies at the most widely used low temperature heat sources within 218 days of a heating period. The monitoring involved horizontal ground heat exchangers (HGHEs) of linear and Slinky type, vertical ground heat exchangers (VGHEs) with single and double U-tube exchanger as well as the ambient air. The results of the verification indicated that it was not possible to specify clearly the most advantageous low-temperature heat source that meets the requirements of the efficiency of the heat pump operation. The highest average heat transfer fluid temperatures were achieved at linear HGHE (8.13 ± 4.50 °C) and double U-tube VGHE (8.13 ± 3.12 °C). The highest average specific heat output 59.97 ± 41.80 W/m2 and specific energy extracted from the ground mass 2723.40 ± 1785.58 kJ/m2·day were recorded at single U-tube VGHE. The lowest thermal resistance value of 0.07 K·m2/W, specifying the efficiency of the heat transfer process between the ground mass and the heat transfer fluid, was monitored at linear HGHE. The use of ambient air as a low-temperature heat pump source was considered to be the least advantageous in terms of its temperature parameters.


Author(s):  
Hasan Gunes ◽  
Sertac Cadirci

In this study we show that the POD can be used as a useful tool to solve inverse design problems in thermo-fluids. In this respect, we consider a forced convection problem of air flow in a grooved channel with periodically mounted constant heat-flux heat sources. It represents a cooling problem in electronic equipments where the coolant is air. The cooling of electronic equipments with constant periodic heat sources is an important problem in the industry such that the maximum operating temperature must be kept below a value specified by the manufacturer. Geometric design in conjunction with the improved convective heat transfer characteristics is important to achieve an effective cooling. We obtain a model based on the proper orthogonal decomposition for the convection optimization problem such that for a given channel geometry and heat flux on the chip surface, we search for the minimum Reynolds number (i.e., inlet flow speed) for a specified maximum surface temperature. For a given geometry (l = 3.0 cm and h = 2.3 cm), we obtain a proper orthogonal decomposition (POD) model for the flow and heat transfer for Reynolds number in the range 1 and 230. It is shown that the POD model can accurately predict the flow and temperature field for off-design conditions and can be used effectively for inverse design problems.


Sign in / Sign up

Export Citation Format

Share Document