Effect of flow control devices on the distribution of magnetic-flow-heat in the channel induction heating tundish

2021 ◽  
pp. 1-11
Author(s):  
Pu Wang ◽  
Xiqing Chen ◽  
Hong Xiao ◽  
Xiaosong Li ◽  
Zhimin Ma ◽  
...  
Metals ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 796
Author(s):  
Dong-Yuan Sheng ◽  
Dengfu Chen

The effects of flow control devices (FCD) in a single-strand tundish, including weir, dam, turbulence inhibitor and gas curtain, have been investigated using water model experiments and CFD simulations. A scaled-down water model was built up to visualize flow pattern and measure the residence-time distribution (RTD) of different tundish configurations. A CFD model was applied to calculate the fluid flow, heat transfer and RTD curves in the prototype tundish under the nonisothermal conditions. The Eulerian–Lagrangian approach was applied to investigate the bubble flow in the system. The results show that each FCD has its own unique function to control the flow. It is important to evaluate the combined effects of FCD based on their installations. The molten steel flow in the tundish could be improved if these flow control devices were arranged properly.


2020 ◽  
Vol 22 (3) ◽  
pp. 619-627
Author(s):  
Luca Fenini ◽  
Stefano Malavasi

Abstract Fluid-dynamic noise emissions produced by flow-control devices inside ducts are a concerning issue for valve manufacturers and pipeline management. This work proposes a modified formulation of Acoustic Perturbation Equations (APE) that is applicable to industrial frameworks where the interest is addressed to noise prediction according to international standards. This formulation is derived from a literature APE system removing two terms allowing for a computational time reduction of about 20%. The physical contribution of the removed terms is discussed according to the literature. The modified APE are applied to the prediction of the noise emitted by an orifice. The reliability of the new APE system is evaluated by comparing the Sound Pressure Level (SPL) and the acoustic pressure with the ones returned by LES and literature APE. The new formulation agrees with the other methods far from the orifice: moving over nine diameters downstream of the trailing edge, the SPL is in accordance with the other models. Since international standards characterize control devices with the noise measured 1 m downstream of them, the modified APE formulation provides reliable and faster noise prediction for those devices with outlet diameter, d, such that 9d < 1 m.


Author(s):  
Mohd. S. Aris ◽  
Ieuan Owen ◽  
Chris. J. Sutcliffe

This paper is concerned with convective heat transfer enhancement of heated surfaces through the use of vortex generators and flow control devices. A preliminary proof-of-concept investigation has been carried out into the use of active vortex generators and flow control elements, both manufactured from Shape Memory Alloys (SMAs) which are activated at set temperatures. The vortex generators change their shape to intrude further into the flow at high temperature to enhance heat transfer, while they maintain a low profile at low temperatures to minimise flow pressure losses. One set of vortex generators was made from pre-alloyed powders of SMA material in an advanced rapid prototyping process known as Selective Laser Melting (SLM). Another set of devices was also made from commercially available flat annealed thin SMA sheets for comparison purposes. The flow control elements are devices that preferentially guide the flow to heated parts of a surface, again using temperature-activated SMAs. Promising results were obtained for both the vortex generator and flow control device when their temperatures were varied from 20° to 85°C. The vortex generators responded by increasing their angle of attack from 20° to 35° while the wavy flow control elements straightened out at higher temperatures. As the designs were two-way trained, they regain their initial position and shape at a lower temperature. The surface temperature of the heated plate on which the active devices were positioned reduced between 8 to 51%, indicating heat transfer enhancement due to the generated vortices and changes in air flow rates.


2021 ◽  
Author(s):  
Mazda Irani ◽  
Nasser Sabet ◽  
Farzad Bashtani ◽  
Kousha Gohari

Summary Although the steam assisted gravity drainage (SAGD) process is still the preferred thermal-recovery process method for Athabascan deposits in Alberta, Canada, the interest in solvent-based techniques is growing due to reduce greenhouse-gas (GHG) emissions and water treatment concerns. In SAGD process, the thermodynamic trapping or subcool trapping is quite efficient due to strongly dependency of bitumen viscosity to temperature. As Irani (2018) discussed subcool trapping for solvent applications such NsolvTM recovery process is inefficient due to week dependency of solvent viscosity to temperature. Other factor that effects the efficiency of the thermodynamic trapping is that the pure solvent injection recovery processes are operated at low pressure and it is not large temperature window for operators to apply large subcools. Such challenges make the pure solvent injection recovery processes a perfect case for deployment of Flow-Control-Devices (FCDs). FCDs have demonstrated significant potential for improving recovery in SAGD production wells. FCD experience in SAGD has been primarily positive and most producers performed better with FCDs. Application of FCDs are even more important in pure-solvent injection recovery processes due to large amount of solvent in the liquid pool and also low latent heat of solvent in comparison of water. With FCDs, the draw-down pressure is typically higher, resulting in flashing near the well bore, which is largely correlated to latent heat of the main fluid in the liquid pool. The flashing creates either steam or vapour breakthrough that causes the reduction in the relative permeability of the liquid phase. Such mobility reduction creates new equilibrium that stabilizes at lower rates. Such new equilibrium analysis is conducted by forcing a new temperature gradient to the model. Such condition creates an environment that leads into extensive solvent-breakthrough called solvent-coning in this study. The main output of such analysis is the produced solvent gas-fraction produced at the sand-face. The gas-fraction is an important input for the flow control devices (FCDs) especially at subcools close to the zero, as it controls its behavior. EoS model is also created and simplified to be possible to used in defining different equilibrium conditions. This type of analysis can help the operators evaluate the effectiveness of different type of FCDs, whether they are primarily momentum- or friction-style devices for application of the pure solvent injection recovery processes. This study is the first of its kind that couple the EoS and Darcy flow in the liquid pool. The model includes all the factors into a liquid-relative-permeability, and limitation of the liquid flow into producer is modeled by Darcy flow and reduction of such relative-permeability.


2021 ◽  
Author(s):  
Elena-Alexandra Chiulan ◽  
Costin Ioan Cosoiu ◽  
Andrei-Mugur Georgescu ◽  
Anton Anton ◽  
Mircea Degeratu

2021 ◽  
Author(s):  
Michael Hardcastle ◽  
Ryan Holmes ◽  
Frank Abbott ◽  
Jesse Stevenson ◽  
Aubrey Tuttle

Abstract Connacher Oil and Gas has deployed Flow Control Devices (FCDs)on an infill well liner as part of a Steam Assisted Gravity Drainage (SAGD) exploitation strategy. Infill wells are horizontal wells drilled in between offsetting SAGD well pairs in order to access bypassed pay and accelerate recovery. These wells can have huge variability in productivity, based on several factors: variable initial temperature due to variable steam chamber development and initial mobility variable injectivity from day one limiting steam circulation and stimulation significant hot spots during production that limit drawdown of the well and oil productivity FCDs have shown great value in several SAGD schemes and are becoming common throughout SAGD applications to manage similar challenges in SAGD pairs, but their application in infill wells is less prevalent and presents a novel challenge to design and evaluate performance. This case study will examine the theory, operation, and early field results of this field trial. Density-based FCDs designed for thermal operations were selected to minimize the impact of viscous fluids commonly encountered early in cold infill well production. The design also limited steam outflow during the stimulation phase, where steam is injected in order to initiate production of the well. Distributed Temperature Sensing (DTS) data, pressures and rates are utilized to analyze the impact of the FCDs towards conformance of the well in the early life. The value of FCDs has led to further piloting of this technology in a second group of nine infill wells, where further value is to be extracted using slimmer wellbores.


Sign in / Sign up

Export Citation Format

Share Document