A Bus Clamping PWM-Based Improved Control of Grid Tied PV Inverter with LCL Filter Under Varying Grid Frequency Condition

2020 ◽  
pp. 1-17
Author(s):  
A. Shantanu Chatterjee
2021 ◽  
Vol 3 (3) ◽  
Author(s):  
Ayaz Ahmad ◽  
L. Rajaji ◽  
A. Iqbal

AbstractDistributed generators are playing a vital role in supporting the grid in ever-increasing energy demands. Grid code regulation must be followed when integrating the photovoltaic inverter system to the grid. The paper investigates and analyzes a controller model for grid-connected PV inverters to inject sinusoidal current to the grid with minimum distortion. To achieve better tracking and disturbance rejection, a DSP-based current controller is designed with LCL filter. The controller gets the current feedback from the grid, compares it with reference current, and calculates duty cycle to generate PWM pulses to trigger H-bridge converters. The grid voltage is loaded to the initial value in proposed PR controller to ensure the initial inverter voltage to match the grid voltage. The paper presents a novel current controller algorithm for grid-connected inverter system, and simulation is done. A detailed analysis has been carried out to validate the proposed design algorithm. Experimental implementation of the current controller in the DC/AC converter circuits with an LCL filter is done for 5.4 kW to validate and match the simulation model.


Author(s):  
K. Arulkumar ◽  
D. Vijayakumar ◽  
K. Palanisamy

The third order LLCL filter is gaining more attractive in grid connected PV inverter in terms of material cost saving than LCL filter. Several active and passive damping techniques prevail in mitigating the resonance problem for maintaining the grid power quality standards. In this paper an improved passive damping is examined with reduction of power loss for the LLCL filter. Particularly, it reduces the switching ripple much better than LCL filter, with a decrease in volume of the inductance. The filter design is also developed for the operation of stiff grid. Mathematical operations and transfer function are derived with frequency response for the accuracy of the filter design. In addition, comparative analysis of passive and improved passive damping control is proposed. The control strategy is improved with feedback linearization in order to avoid the glitches in inverter control and is verified with prototype grid connected PV inverter.


2017 ◽  
Vol 2017 ◽  
pp. 1-13 ◽  
Author(s):  
Ali Algaddafi ◽  
Saud A. Altuwayjiri ◽  
Oday A. Ahmed ◽  
Ibrahim Daho

Grid connected inverters play a crucial role in generating energy to be fed to the grid. A filter is commonly used to suppress the switching frequency harmonics produced by the inverter, this being passive, and either an L- or LCL-filter. The latter is smaller in size compared to the L-filter. But choosing the optimal values of the LCL-filter is challenging due to resonance, which can affect stability. This paper presents a simple inverter controller design with an L-filter. The control topology is simple and applied easily using traditional control theory. Fast Fourier Transform analysis is used to compare different grid connected inverter control topologies. The modelled grid connected inverter with the proposed controller complies with the IEEE-1547 standard, and total harmonic distortion of the output current of the modelled inverter has been just 0.25% with an improved output waveform. Experimental work on a commercial PV inverter is then presented, including the effect of strong and weak grid connection. Inverter effects on the resistive load connected at the point of common coupling are presented. Results show that the voltage and current of resistive load, when the grid is interrupted, are increased, which may cause failure or damage for connecting appliances.