DIAPHRAGM ACTION OF SANDWICH PANELS IN PIN-JOINTED STEEL STRUCTURES: A SEISMIC STUDY

2000 ◽  
Vol 4 (3) ◽  
pp. 251-275 ◽  
Author(s):  
GIANFRANCO DE MATTEIS ◽  
RAFFAELE LANDOLFO
2018 ◽  
Vol 9 (5) ◽  
pp. 705-720 ◽  
Author(s):  
Ehsan Bazarchi ◽  
Yousef Hosseinzadeh ◽  
Parinaz Panjebashi Aghdam

Purpose It is common practice in structural engineering to assume floor diaphragms infinitely stiff in their own plane. But, most of the code provisions lack clarity and unity in categorising floor diaphragms and discussing their behaviour based on the seismic response of the structures. Besides, although many of these code provisions have presented simple techniques and formulations for determining the level of flexibility in floor diaphragms, the implementation of these techniques on more complex floor systems such as the steel-deck composite floors is still under question. The paper aims to discuss these issues. Design/methodology/approach In this study, an equivalent concrete floor is employed as a representative of in-plane diaphragm action of steel-deck composite floor, using simple modelling techniques in SAP2000 and the results are validated by complex structural models developed in ABAQUS. Afterwards, the equivalent floor is inserted to 3, 5 and 7 storey steel structures with 2, 3 and 5 plan aspect ratios in two categories of structures with rigid diaphragms and analogous structures with flexible diaphragms and the responses are compared to each other. Findings The results show that the proposed technique is an effective method for evaluating the diaphragm action of steel-deck composite floors. Additionally, it is concluded that, the boundary values of plan aspect ratio equal to 3 and λ coefficient equal to 0.5 in steel-deck composite floors, mentioned in code provisions for categorising diaphragms, are not always conservative and need to be scrutinised. Originality/value The proposed methodology provides simple framework for assessing the effects of in-plane flexibility of steel-deck composite on seismic response of steel structures.


1994 ◽  
Vol 31 (2-3) ◽  
pp. 305-316 ◽  
Author(s):  
Rolf Baehre ◽  
Thomas Ladwein

The choice of cost-effective method of anticorrosive protection of steel structures is an urgent and time consuming task, considering the significant number of protection ways, differing from each other in the complex of technological, physical, chemical and economic characteristics. To reduce the complexity of solving this problem, the author proposes a computational tool that can be considered as a subsystem of computer-aided design and used at the stage of variant and detailed design of steel structures. As a criterion of the effectiveness of the anti-corrosion protection method, the cost of the protective coating during the service life is accepted. The analysis of existing methods of steel protection against corrosion is performed, the possibility of their use for the protection of the most common steel structures is established, as well as the estimated period of effective operation of the coating. The developed computational tool makes it possible to choose the best method of protection of steel structures against corrosion, taking into account the operating conditions of the protected structure and the possibility of using a protective coating.


2016 ◽  
Vol 12 (1) ◽  
pp. 28-35
Author(s):  
H.M. Nykyforchyn ◽  
◽  
V.A. Chervatyuk ◽  
V.I. Marukha ◽  
Z.V. Slobodyan ◽  
...  

PCI Journal ◽  
1991 ◽  
Vol 36 (6) ◽  
pp. 78-98 ◽  
Author(s):  
Amin Einea ◽  
David C. Salmon ◽  
Gyula J. Fogarasi ◽  
Todd D. Culp ◽  
Maher K. Tadros

Sign in / Sign up

Export Citation Format

Share Document