scholarly journals Channel discrimination along all contacts of the cochlear implant electrode array and its relation to speech perception

2019 ◽  
Vol 58 (5) ◽  
pp. 262-268
Author(s):  
Jan Dirk Biesheuvel ◽  
Jeroen J. Briaire ◽  
Monique A. M. de Jong ◽  
Stefan Boehringer ◽  
Johan H. M. Frijns
2016 ◽  
Vol 21 (5) ◽  
pp. 316-325 ◽  
Author(s):  
M. Annerie van der Jagt ◽  
Jeroen J. Briaire ◽  
Berit M. Verbist ◽  
Johan H.M. Frijns

The HiFocus Mid-Scala (MS) electrode array has recently been introduced onto the market. This precurved design with a targeted mid-scalar intracochlear position pursues an atraumatic insertion and optimal distance for neural stimulation. In this study we prospectively examined the angular insertion depth achieved and speech perception outcomes resulting from the HiFocus MS electrode array for 6 months after implantation, and retrospectively compared these with the HiFocus 1J lateral wall electrode array. The mean angular insertion depth within the MS population (n = 96) was found at 470°. This was 50° shallower but more consistent than the 1J electrode array (n = 110). Audiological evaluation within a subgroup, including only postlingual, unilaterally implanted, adult cochlear implant recipients who were matched on preoperative speech perception scores and the duration of deafness (MS = 32, 1J = 32), showed no difference in speech perception outcomes between the MS and 1J groups. Furthermore, speech perception outcome was not affected by the angular insertion depth or frequency mismatch.


2018 ◽  
Vol 23 (6) ◽  
pp. 345-355 ◽  
Author(s):  
Miryam  Calvino ◽  
Isabel  Sánchez-Cuadrado ◽  
Javier Gavilán ◽  
Luis Lassaletta

Background: The otosclerotic process may influence the performance of the cochlear implant (CI). Difficulty in inserting the electrode array due to potential ossification of the cochlea, facial nerve stimulation, and instability of the results are potential challenges for the CI team. Objectives: To evaluate hearing results and subjective outcomes of CI users with otosclerosis and to compare them with those of CI users without otosclerosis. Method: Retrospective review of 239 adults with bilateral profound postlingual deafness who underwent unilateral cochlear implantation between 1992 and 2017. Hearing and speech understanding were assessed via pure-tone audiometry and speech perception tests. Subjective outcomes were assessed via the Nijmegen Cochlear Implant Questionnaire (NCIQ), the Glasgow Benefit Inventory (GBI), and the Hearing Implant Sound Quality Index (HISQUI19) at 6 months, 12 months, and at the last follow-up. Results: Subjects were 22 CI users with otosclerosis and 217 without otosclerosis. Both groups had a similar duration of deafness and age at CI implantation. Results did not significantly differ according to group: no significant intergroup difference was found regarding the frequency of complete electrode insertion, facial stimulation, reimplantation, or PTA4 scores at the last follow-up. Regarding speech perception, no significant intergroup difference was found on any test or at any interval. Further, subjective outcomes, as measured by the GBI, NCIQ, and HISQUI19, did not significantly differ between groups. Conclusions: Adults with otosclerosis and profound hearing loss derive significant benefit from CI use. Audiological and self-reported outcomes are not significantly different from that of other CI users with postlingual deafness.


2010 ◽  
Vol 10 ◽  
pp. 329-339 ◽  
Author(s):  
Torsten Rahne ◽  
Michael Ziese ◽  
Dorothea Rostalski ◽  
Roland Mühler

This paper describes a logatome discrimination test for the assessment of speech perception in cochlear implant users (CI users), based on a multilingual speech database, the Oldenburg Logatome Corpus, which was originally recorded for the comparison of human and automated speech recognition. The logatome discrimination task is based on the presentation of 100 logatome pairs (i.e., nonsense syllables) with balanced representations of alternating “vowel-replacement” and “consonant-replacement” paradigms in order to assess phoneme confusions. Thirteen adult normal hearing listeners and eight adult CI users, including both good and poor performers, were included in the study and completed the test after their speech intelligibility abilities were evaluated with an established sentence test in noise. Furthermore, the discrimination abilities were measured electrophysiologically by recording the mismatch negativity (MMN) as a component of auditory event-related potentials. The results show a clear MMN response only for normal hearing listeners and CI users with good performance, correlating with their logatome discrimination abilities. Higher discrimination scores for vowel-replacement paradigms than for the consonant-replacement paradigms were found. We conclude that the logatome discrimination test is well suited to monitor the speech perception skills of CI users. Due to the large number of available spoken logatome items, the Oldenburg Logatome Corpus appears to provide a useful and powerful basis for further development of speech perception tests for CI users.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Ben Somers ◽  
Christopher J. Long ◽  
Tom Francart

AbstractThe cochlear implant is one of the most successful medical prostheses, allowing deaf and severely hearing-impaired persons to hear again by electrically stimulating the auditory nerve. A trained audiologist adjusts the stimulation settings for good speech understanding, known as “fitting” the implant. This process is based on subjective feedback from the user, making it time-consuming and challenging, especially in paediatric or communication-impaired populations. Furthermore, fittings only happen during infrequent sessions at a clinic, and therefore cannot take into account variable factors that affect the user’s hearing, such as physiological changes and different listening environments. Objective audiometry, in which brain responses evoked by auditory stimulation are collected and analysed, removes the need for active patient participation. However, recording of brain responses still requires expensive equipment that is cumbersome to use. An elegant solution is to record the neural signals using the implant itself. We demonstrate for the first time the recording of continuous electroencephalographic (EEG) signals from the implanted intracochlear electrode array in human subjects, using auditory evoked potentials originating from different brain regions. This was done using a temporary recording set-up with a percutaneous connector used for research purposes. Furthermore, we show that the response morphologies and amplitudes depend crucially on the recording electrode configuration. The integration of an EEG system into cochlear implants paves the way towards chronic neuro-monitoring of hearing-impaired patients in their everyday environment, and neuro-steered hearing prostheses, which can autonomously adjust their output based on neural feedback.


Author(s):  
Philipp Aebischer ◽  
Georgios Mantokoudis ◽  
Stefan Weder ◽  
Lukas Anschutz ◽  
Marco Caversaccio ◽  
...  

2021 ◽  
Vol 11 (2) ◽  
pp. 220-226
Author(s):  
Yew-Song Cheng ◽  
Mario A. Svirsky

The presence of spiral ganglion cells (SGCs) is widely accepted to be a prerequisite for successful speech perception with a cochlear implant (CI), because SGCs provide the only known conduit between the implant electrode and the central auditory system. By extension, it has been hypothesized that the number of SGCs might be an important factor in CI outcomes. An impressive body of work has been published on findings from the laborious process of collecting temporal bones from CI users and counting the number of SGCs to correlate those numbers with speech perception scores, but the findings thus far have been conflicting. We performed a meta-analysis of all published studies with the hope that combining existing data may help us reach a more definitive conclusion about the relationship between SGC count and speech perception scores in adults.


2021 ◽  
Vol 11 (9) ◽  
pp. 4144
Author(s):  
Ohad Cohen ◽  
Jean-Yves Sichel ◽  
Chanan Shaul ◽  
Itay Chen ◽  
J. Thomas Roland ◽  
...  

Although malpositioning of the cochlear implant (CI) electrode array is rare in patients with normal anatomy, when occurring it may result in reduced hearing outcome. In addition to intraoperative electrophysiologic tests, imaging is an important modality to assess correct electrode array placement. The purpose of this report was to assess the incidence and describe cases in which intraoperative plain radiographs detected a malpositioned array. Intraoperative anti-Stenver’s view plain X-rays are conducted routinely in all CI surgeries in our tertiary center before awakening the patient and breaking the sterile field. Data of patients undergoing 399 CI surgeries were retrospectively analyzed. A total of 355 had normal inner ear and temporal bone anatomy. Patients with intra or extracochlear malpositioned electrode arrays demonstrated in the intraoperative X-ray were described. There were four cases of electrode array malposition out of 355 implantations with normal anatomy (1.1%): two tip fold-overs, one extracochlear placement and one partial insertion. All electrodes were reinserted immediately; repeated radiographs were normal and the patients achieved good hearing function. Intraoperative plain anti-Stenver’s view X-rays are valuable to confirm electrode array location, allowing correction before the conclusion of surgery. These radiographs are cheaper, faster, and emit much less radiation than other imaging options, making them a viable cost-effective tool in patients with normal anatomy.


1993 ◽  
Vol 94 (6) ◽  
pp. 3178-3189 ◽  
Author(s):  
R. J. M. van Hoesel ◽  
Y. C. Tong ◽  
R. D. Hollow ◽  
G. M. Clark

Sign in / Sign up

Export Citation Format

Share Document