Behaviour of liquid storage tanks with VCFPS under near-fault ground motions

2012 ◽  
Vol 8 (1) ◽  
pp. 71-88 ◽  
Author(s):  
V. R. Panchal ◽  
R. S. Jangid
2016 ◽  
Vol 24 (24) ◽  
pp. 5747-5764 ◽  
Author(s):  
Sina Safari ◽  
Reza Tarinejad

Seismic response of base isolated steel liquid storage tanks is investigated in this study by a stochastic approach in frequency domain. For the purpose of evaluating different frequency contents of seismic events on the responses of fixed and isolated tanks, the earthquake excitation is characterized by power spectral density function. Since earthquake is a random process, stochastic seismic analysis is used and root mean square response predicts behavior of system properly. Two types of isolation system are assumed and nonlinear behavior of base isolation systems are developed by an iterative statistical linearization scheme. The study demonstrates the influence of each characteristic parameter of the storage tanks and isolation system and also excitation features. It is confirmed that near-fault earthquake excitations amplify the overall response of the system. Base isolation is known as an effective technique to reduce responses appropriately. It is demonstrated that the sloshing responses of the tanks is significantly reduced by sliding bearing. Further, excitation parameters, PGV/PGA ratio of records and pulse period in near-fault ground motions, that represent differences in two sets of earthquakes are defined to recognize variation of responses.


2018 ◽  
Vol 112 ◽  
pp. 58-68 ◽  
Author(s):  
Eren Uckan ◽  
Önder Umut ◽  
Fatma Nurten Sisman ◽  
Shaghayegh Karimzadeh ◽  
Aysegul Askan

2020 ◽  
Vol 2020 ◽  
pp. 1-10
Author(s):  
Lijian Zhou ◽  
Tian Xu ◽  
Zhaohong Lu ◽  
Dong Zhang

In this study, through a vibration table test, finite element simulation, and research on the rationality of the wave-height fortification of national storage tank specifications, the sloshing response of vertical storage tanks under the action of near-fault ground motion was analyzed. The test results showed that the sloshing wave height of a vertical storage tank was larger under near-fault or long-period ground motions, and the relationship between the sloshing wave height and the peak acceleration of input ground motions was approximately linear. The numerical simulations of the model tank showed that the simulation wave height and the test wave-height data were well fitted. Therefore, it was feasible to simulate the sloshing of large vertical storage tanks using ADINA software. In addition, a large number of sloshing simulations of near-fault ground motions on 10,000 m3 vertical storage tanks were performed. The simulated wave height had a high correlation with the predominant period or pulse period of near-fault ground motions. Under the calculation with similar parameters, the wave height of the tank standard in several countries had a lower fortification of the near-fault excitation wave height. Through the root mean-square method using a small sample size, a wave-height correction under a near-fault effect was applied to the wave-height formula for the Chinese tank seismic specification. Finally, the problem of a double-damping correction was addressed by adjusting China’s GB50341 wave-height formula. This work provides a reference value for practical engineering applications.


2016 ◽  
Vol 24 (7) ◽  
pp. 1264-1282 ◽  
Author(s):  
Saman Bagheri ◽  
Mostafa Farajian

There are several methods to reduce the seismic damages in liquid storage tanks. One of these methods is to use passive control devices, in particular seismic base isolators. Among the different base isolation systems, the Friction Pendulum System (FPS) whose period does not depend on the weight of the system is more appropriate for isolation of liquid storage tanks. The aim of this paper is to investigate the effects of peak ground acceleration (PGA) and pulselike characteristics of earthquakes on the seismic behavior of steel liquid storage tanks base isolated by FPS bearings. In addition, impact effects of the slider with the side retainer are investigated, as well as effects of tank aspect ratio, isolation period and friction coefficient. The obtained results of tanks with different aspect ratios indicate that the responses get more reduced due to isolation under far-field ground motions compared to near-fault ground motions. It is also seen that the response of a base isolated tank is affected when contact takes place with the side retainer of the FPS.