scholarly journals Corrigendum: Human microvascular reactivity: a review of vasomodulating stimuli and non-invasive imaging assessment (2021 Physiol. Meas. 42 09TR01)

2021 ◽  
Vol 42 (10) ◽  
pp. 109501
Author(s):  
Aaron M Troy ◽  
Hai-Ling Margaret Cheng
2020 ◽  
Vol 107 (1) ◽  
pp. 134-144
Author(s):  
V. Tóth-Szűki ◽  
F. Bari ◽  
F. Domoki

AbstractMicrovascular function has been assessed by determining the rhythmic oscillations in blood flow induced by the vasomotion of resistance vessels. Although laser-Doppler flowmetry (LDF) allows simple, non-invasive evaluation of this flow-motion in the cutaneous microcirculation, the temporal and spatial reproducibility of such assessments remains unclear.In the present study, we investigated cutaneous flow-motion in three consecutive years in eight skin regions using LDF in six healthy young volunteers. The characteristic flow-motion frequency was determined using fast-Fourier transformation. Additionally, in two years a more traditional measure of microvascular reactivity, postocclusive reactive hyperemia (PORH) was evoked in the forearm after transient brachial artery occlusion (1–2–3 min) induced by cuff inflation.Well-defined flow-motion was found in six regions showing significant differences in frequency: the highest flow-motion frequency was found in the frontal and temporal regions (8.0 ± 1.1 and 8.5 ± 1.0 cycles/min, cpm, respectively, mean ± SD) followed by the scapular, infraclavicular and coxal regions (7.5 ± 1.3; 6.7 ± 1.1 and 6.5 ± 1.2 cpm, respectively). The lowest, stable flow-motion was found in the posterior femoral region (5.5 ± 1.0 cpm), whereas flow-motion was detectable only sporadically in the limbs. The region-dependent flow-motion frequencies were very stable within individuals either between the body sides, or among the three measurements, only the infraclavicular region showed a small difference (114 ± 17%∗, % of value in 1st year; ∗P < 0.05). However, PORH indices differed after 2–3 min occlusions significantly in consecutive years.We report that flow-motion frequencies determined from LDF signals show both region-specificity and excellent intra-individual temporal and spatial reproducibility suggesting their usefulness for non-invasive follow-up of microvascular reactivity.


Author(s):  
H.W. Deckman ◽  
B.F. Flannery ◽  
J.H. Dunsmuir ◽  
K.D' Amico

We have developed a new X-ray microscope which produces complete three dimensional images of samples. The microscope operates by performing X-ray tomography with unprecedented resolution. Tomography is a non-invasive imaging technique that creates maps of the internal structure of samples from measurement of the attenuation of penetrating radiation. As conventionally practiced in medical Computed Tomography (CT), radiologists produce maps of bone and tissue structure in several planar sections that reveal features with 1mm resolution and 1% contrast. Microtomography extends the capability of CT in several ways. First, the resolution which approaches one micron, is one thousand times higher than that of the medical CT. Second, our approach acquires and analyses the data in a panoramic imaging format that directly produces three-dimensional maps in a series of contiguous stacked planes. Typical maps available today consist of three hundred planar sections each containing 512x512 pixels. Finally, and perhaps of most import scientifically, microtomography using a synchrotron X-ray source, allows us to generate maps of individual element.


2001 ◽  
Vol 120 (5) ◽  
pp. A266-A266
Author(s):  
R BUTLER ◽  
B ZACHARAKIS ◽  
D MOORE ◽  
K CRAWFORD ◽  
G DAVIDSON ◽  
...  

2001 ◽  
Vol 120 (5) ◽  
pp. A491-A491 ◽  
Author(s):  
A LEODOLTER ◽  
D VAIRA ◽  
F BAZZOLL ◽  
A HIRSCHL ◽  
F MEGRAUD ◽  
...  
Keyword(s):  

2020 ◽  
Vol 158 (6) ◽  
pp. S-1249
Author(s):  
Yuri Hanada ◽  
Juan Reyes Genere ◽  
Bryan Linn ◽  
Tiffany Mangels-Dick ◽  
Kenneth K. Wang

2007 ◽  
Vol 177 (4S) ◽  
pp. 430-430
Author(s):  
Ram Ganapathi ◽  
Troy R. Gianduzzo ◽  
Arul Mahadevan ◽  
Monish Aron ◽  
Lee E. Ponsky ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document